Comparison between prospectively electrocardiogram-gated high-pitch mode and retrospectively electrocardiogram-gated mode for dual-source CT coronary angiography

2015
journal article
article
6
dc.abstract.enBACKGROUND: We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated "Flash Spiral" technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. MATERIAL AND METHODS: A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. RESULTS: A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47-2.01 mSv) for method A and 8.22 mSv (2.19-12.88 mSv) for method B. CONCLUSIONS: Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.pl
dc.contributor.authorKoplay, Mustafapl
dc.contributor.authorCelik, Mahmutpl
dc.contributor.authorAvci, Ahmetpl
dc.contributor.authorErdogan, Hasanpl
dc.contributor.authorDemir, Kenanpl
dc.contributor.authorSivri, Mesutpl
dc.contributor.authorNayman, Alaaddinpl
dc.date.accessioned2017-07-18T12:29:40Z
dc.date.available2017-07-18T12:29:40Z
dc.date.issued2015pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 567-568pl
dc.description.physical561-568pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume80pl
dc.identifier.doi10.12659/PJR.895232pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/42933
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.encoronary angiographypl
dc.subject.enheart ratepl
dc.subject.enimage enhancementpl
dc.subject.enmultidetector computed tomographypl
dc.subject.enradiation dosagepl
dc.subject.enradiologypl
dc.subtypeArticlepl
dc.titleComparison between prospectively electrocardiogram-gated high-pitch mode and retrospectively electrocardiogram-gated mode for dual-source CT coronary angiographypl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
BACKGROUND: We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated "Flash Spiral" technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. MATERIAL AND METHODS: A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. RESULTS: A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47-2.01 mSv) for method A and 8.22 mSv (2.19-12.88 mSv) for method B. CONCLUSIONS: Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.
dc.contributor.authorpl
Koplay, Mustafa
dc.contributor.authorpl
Celik, Mahmut
dc.contributor.authorpl
Avci, Ahmet
dc.contributor.authorpl
Erdogan, Hasan
dc.contributor.authorpl
Demir, Kenan
dc.contributor.authorpl
Sivri, Mesut
dc.contributor.authorpl
Nayman, Alaaddin
dc.date.accessioned
2017-07-18T12:29:40Z
dc.date.available
2017-07-18T12:29:40Z
dc.date.issuedpl
2015
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 567-568
dc.description.physicalpl
561-568
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
80
dc.identifier.doipl
10.12659/PJR.895232
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/42933
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
coronary angiography
dc.subject.enpl
heart rate
dc.subject.enpl
image enhancement
dc.subject.enpl
multidetector computed tomography
dc.subject.enpl
radiation dosage
dc.subject.enpl
radiology
dc.subtypepl
Article
dc.titlepl
Comparison between prospectively electrocardiogram-gated high-pitch mode and retrospectively electrocardiogram-gated mode for dual-source CT coronary angiography
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
6
Views per month
Views per city
Hong Kong
4
Ashburn
1
Downloads
koplay_celik_avci_erdogan_demir_sivri_nayman_comparison_between_prospectively_electrocardiogram-gated_high-pitch_mode_2015.pdf
16