Histopathology and elastography discordance in evaluation of breast lesions with acoustic radiation force impulse elastography

2019
journal article
article
5
dc.abstract.enPurpose: It is known that, besides its benefits, ultrasound (US) elastography may show discordance findings, leading to biopsy, so this technique has some limitations. The purpose of the present study was to compare histopathological results and shear wave velocity (SWV) values in patients, to reveal discordance findings, and to investigate its statistical significance in making the decision for biopsy with SWV values. Material and methods: A total of 190 patients presenting with breast lesions were included in the study. The mean age of the patients was 39.87 ± 13.56 years. All morphological features of lesions were evaluated by B-mode US. The mean SWV values were measured using the region of interest (ROI) through all lesions with ARFI elastography. An ultrasound-guided Tru-Cut needle biopsy was performed, and histopathologic data were obtained. Results: The SWV values of false positive benign lesions, such as: granulomatous mastitis, sclerosing adenosis, chronic inflammation, fat necrosis, fibrotic breast tissue, and scar tissue, were as high as the SWV values of malignant lesions. Sensitivity was found as 91.6% and specificity as 40.9% for SWV values in ARFI US. Conclusions: Our results showed that breast lesions showed false positivity (59.1%) and false negativity (8.3%) in ARFI US. Elastography is useful and sensitive in the evaluation of breast lesions, but some benign lesions may mimic malignant lesions; thus, this information should not be underestimated in biopsy decision-making for elastography users.pl
dc.contributor.authorToprak, Nurşenpl
dc.contributor.authorYokus, Adempl
dc.contributor.authorGündüz, Mahirpl
dc.contributor.authorAkdenız, Huseyınpl
dc.date.accessioned2019-07-29T07:13:18Z
dc.date.available2019-07-29T07:13:18Z
dc.date.issued2019pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e232-e233pl
dc.description.physicale224-e233pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume84pl
dc.identifier.doi10.5114/pjr.2019.86852pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/79888
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.source.integratorfalse
dc.subject.enbreast lesionpl
dc.subject.enARFI elastographypl
dc.subject.endiscordant findingspl
dc.subtypeArticlepl
dc.titleHistopathology and elastography discordance in evaluation of breast lesions with acoustic radiation force impulse elastographypl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Purpose: It is known that, besides its benefits, ultrasound (US) elastography may show discordance findings, leading to biopsy, so this technique has some limitations. The purpose of the present study was to compare histopathological results and shear wave velocity (SWV) values in patients, to reveal discordance findings, and to investigate its statistical significance in making the decision for biopsy with SWV values. Material and methods: A total of 190 patients presenting with breast lesions were included in the study. The mean age of the patients was 39.87 ± 13.56 years. All morphological features of lesions were evaluated by B-mode US. The mean SWV values were measured using the region of interest (ROI) through all lesions with ARFI elastography. An ultrasound-guided Tru-Cut needle biopsy was performed, and histopathologic data were obtained. Results: The SWV values of false positive benign lesions, such as: granulomatous mastitis, sclerosing adenosis, chronic inflammation, fat necrosis, fibrotic breast tissue, and scar tissue, were as high as the SWV values of malignant lesions. Sensitivity was found as 91.6% and specificity as 40.9% for SWV values in ARFI US. Conclusions: Our results showed that breast lesions showed false positivity (59.1%) and false negativity (8.3%) in ARFI US. Elastography is useful and sensitive in the evaluation of breast lesions, but some benign lesions may mimic malignant lesions; thus, this information should not be underestimated in biopsy decision-making for elastography users.
dc.contributor.authorpl
Toprak, Nurşen
dc.contributor.authorpl
Yokus, Adem
dc.contributor.authorpl
Gündüz, Mahir
dc.contributor.authorpl
Akdenız, Huseyın
dc.date.accessioned
2019-07-29T07:13:18Z
dc.date.available
2019-07-29T07:13:18Z
dc.date.issuedpl
2019
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e232-e233
dc.description.physicalpl
e224-e233
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
84
dc.identifier.doipl
10.5114/pjr.2019.86852
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/79888
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.source.integrator
false
dc.subject.enpl
breast lesion
dc.subject.enpl
ARFI elastography
dc.subject.enpl
discordant findings
dc.subtypepl
Article
dc.titlepl
Histopathology and elastography discordance in evaluation of breast lesions with acoustic radiation force impulse elastography
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
24
Views per month
Views per city
Hong Kong
6
Ashburn
5
Dublin
3
Wroclaw
2
Chandler
1
Warsaw
1
Downloads
toprak_yokus_gunduz_akdeniz_histopathology_and_elastography_discordance_in_evaluation_2019.odt
390
toprak_yokus_gunduz_akdeniz_histopathology_and_elastography_discordance_in_evaluation_2019.pdf
40