Simple view
Full metadata view
Authors
Statistics
Virtual planning of dental implant placement using CT double-scan technique : own experience
implants
computed tomography
preoperative planning
3D imaging
Bibliogr. s. 49
Background: The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. Material/Methods: The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10x0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. Results: In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical conditions. Conclusions: Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed.
dc.abstract.en | Background: The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. Material/Methods: The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10x0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. Results: In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical conditions. Conclusions: Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. | pl |
dc.affiliation | Wydział Lekarski : Zakład Radiologii | pl |
dc.contributor.author | Wojciechowski, Wadim - 133810 | pl |
dc.contributor.author | Kownacki, Patryk | pl |
dc.contributor.author | Kownacki, Stanisław | pl |
dc.contributor.author | Urbanik, Andrzej - 133713 | pl |
dc.date.accession | 2019-06-26 | pl |
dc.date.accessioned | 2019-06-26T15:13:58Z | |
dc.date.available | 2019-06-26T15:13:58Z | |
dc.date.issued | 2007 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. 49 | pl |
dc.description.number | 4 | pl |
dc.description.physical | 44-49 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 72 | pl |
dc.identifier.articleid | 510496 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.project | ROD UJ / OP | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/78075 | |
dc.identifier.weblink | http://archiwum.inforadiologia.pl/download/index/idArt/510496 | pl |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | implants | pl |
dc.subject.en | computed tomography | pl |
dc.subject.en | preoperative planning | pl |
dc.subject.en | 3D imaging | pl |
dc.subtype | Article | pl |
dc.title | Virtual planning of dental implant placement using CT double-scan technique : own experience | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
5
Views per month
Views per city
Downloads
Open Access