Quality standards in mammography

2007
journal article
review article
dc.abstract.enThe paper presents the incidence of breast cancer in Poland and the correlation between 5-year survival and the stage at which the tumors are detected, based on epidemiological data. Emphasizing the importance of population screening programs, the conditions that should be fulfilled by X-ray mammography - the main method of breast cancer detection - its role, limitations, approaches, and reasons for incorrect diagnoses are presented. The clinical signs of asymptomatic breast cancer are described and the techniques of an accurate X-ray mammography performance are discussed. The BI-RADS system developed by the American College of Radiology (ACR), is suggested to be a standard for mammography interpretation in the final conclusions and recommendations for further management. The sensitivity of the method enables detection of 80-90% clinically asymptomatic lesions, depending on a the breast structure. To obtain such results, high quality of examination is a must. Therefore, it is essential to implement a quality control program at each stage of the examination across all participating mammography labs.pl
dc.contributor.authorWesołowska, Ewapl
dc.date.accession2019-06-13pl
dc.date.accessioned2019-06-13T10:22:54Z
dc.date.available2019-06-13T10:22:54Z
dc.date.issued2007pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 42pl
dc.description.number3pl
dc.description.physical40-42pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume72pl
dc.identifier.articleid492493pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/77115
dc.identifier.weblinkhttp://archiwum.inforadiologia.pl/download/index/idArt/492493.htmlpl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enmammographypl
dc.subject.enbreast cancer detectionpl
dc.subject.enBI-RADS systempl
dc.subject.enquality control programspl
dc.subtypeReviewArticlepl
dc.titleQuality standards in mammographypl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
The paper presents the incidence of breast cancer in Poland and the correlation between 5-year survival and the stage at which the tumors are detected, based on epidemiological data. Emphasizing the importance of population screening programs, the conditions that should be fulfilled by X-ray mammography - the main method of breast cancer detection - its role, limitations, approaches, and reasons for incorrect diagnoses are presented. The clinical signs of asymptomatic breast cancer are described and the techniques of an accurate X-ray mammography performance are discussed. The BI-RADS system developed by the American College of Radiology (ACR), is suggested to be a standard for mammography interpretation in the final conclusions and recommendations for further management. The sensitivity of the method enables detection of 80-90% clinically asymptomatic lesions, depending on a the breast structure. To obtain such results, high quality of examination is a must. Therefore, it is essential to implement a quality control program at each stage of the examination across all participating mammography labs.
dc.contributor.authorpl
Wesołowska, Ewa
dc.date.accessionpl
2019-06-13
dc.date.accessioned
2019-06-13T10:22:54Z
dc.date.available
2019-06-13T10:22:54Z
dc.date.issuedpl
2007
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 42
dc.description.numberpl
3
dc.description.physicalpl
40-42
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
72
dc.identifier.articleidpl
492493
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/77115
dc.identifier.weblinkpl
http://archiwum.inforadiologia.pl/download/index/idArt/492493.html
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
mammography
dc.subject.enpl
breast cancer detection
dc.subject.enpl
BI-RADS system
dc.subject.enpl
quality control programs
dc.subtypepl
ReviewArticle
dc.titlepl
Quality standards in mammography
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
2
Views per month
Views per city
San Jose
1
Downloads
wesolowska_quality_standards_in_mammography_2007.odt
10
wesolowska_quality_standards_in_mammography_2007.pdf
9