Core breast biopsy under MR control : preliminary results

2007
journal article
article
dc.abstract.enBackground: Breast MR examination is capable of detecting suspected lesions that are not visualized by other imaging techniques, such as mammography or ultrasonography. In all cases such lesions should be verified histopathologically by MR-guided core biopsy. The aim of the study was the determination of effectiveness of MR-guided breast core biopsy in detection of breast pathologies. Material/Methods: Twelve women with suspected lesions detected by MR (GEMS Signa Excite 1.5 T with 4-channel open breast coil manufactured by MRI Devices Corporation) were qualified to MR-guided breast biopsy. Obtained image data were transferred to DYNACAD workstation for calibration, lesion localization, and automatic calculation of target coordinates for MR-guided intervention. Biopsy was performed using automated 14G biopsy needle. Results: MR-guided breast biopsy was performed in 9 women and confirmed lobular and ductal carcinoma in 2 patients respectively, lobular carcinoma in situ (LCIS) in 1, intraductal papilloma in 2, and intraductal hyperplasia without atypia. In 3 patients histopathologic examination revealed benign fibrocystic lesions. Three women were disqualified from biopsy because pre-biopsy MR sequences did not reveal the lesion in 1 case, and due to the target localization out of reach of the biopsy needle in other 2 cases. Conclusions: All non-palpable lesions visualized by MR (contrast-enhanced signal in dynamic examination) should be verified by MR-guided breast biopsy. In each case histopathologicpl
dc.affiliationWydział Lekarski : Klinika Chirurgii Ogólnej, Onkologicznej i Gastroenterologicznejpl
dc.affiliationWydział Lekarski : Zakład Radiologiipl
dc.contributor.authorPopiela, Tadeusz - 133200 pl
dc.contributor.authorHerman-Sucharska, Irenapl
dc.contributor.authorKleinrok, Krzysztofpl
dc.contributor.authorUrbanik, Andrzej - 133713 pl
dc.contributor.authorPodsiadło-Kleinrok, Beatapl
dc.contributor.authorTabor, Jacekpl
dc.date.accession2019-06-06pl
dc.date.accessioned2019-06-06T07:31:28Z
dc.date.available2019-06-06T07:31:28Z
dc.date.issued2007pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 24pl
dc.description.number2pl
dc.description.physical15-24pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume72pl
dc.identifier.articleid478058pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/76678
dc.identifier.weblinkhttp://archiwum.inforadiologia.pl/download/index/idArt/478058.htmlpl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enbreast MRpl
dc.subject.enMR breast biopsypl
dc.subject.enMR guided core breast core biopsypl
dc.subtypeArticlepl
dc.titleCore breast biopsy under MR control : preliminary resultspl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: Breast MR examination is capable of detecting suspected lesions that are not visualized by other imaging techniques, such as mammography or ultrasonography. In all cases such lesions should be verified histopathologically by MR-guided core biopsy. The aim of the study was the determination of effectiveness of MR-guided breast core biopsy in detection of breast pathologies. Material/Methods: Twelve women with suspected lesions detected by MR (GEMS Signa Excite 1.5 T with 4-channel open breast coil manufactured by MRI Devices Corporation) were qualified to MR-guided breast biopsy. Obtained image data were transferred to DYNACAD workstation for calibration, lesion localization, and automatic calculation of target coordinates for MR-guided intervention. Biopsy was performed using automated 14G biopsy needle. Results: MR-guided breast biopsy was performed in 9 women and confirmed lobular and ductal carcinoma in 2 patients respectively, lobular carcinoma in situ (LCIS) in 1, intraductal papilloma in 2, and intraductal hyperplasia without atypia. In 3 patients histopathologic examination revealed benign fibrocystic lesions. Three women were disqualified from biopsy because pre-biopsy MR sequences did not reveal the lesion in 1 case, and due to the target localization out of reach of the biopsy needle in other 2 cases. Conclusions: All non-palpable lesions visualized by MR (contrast-enhanced signal in dynamic examination) should be verified by MR-guided breast biopsy. In each case histopathologic
dc.affiliationpl
Wydział Lekarski : Klinika Chirurgii Ogólnej, Onkologicznej i Gastroenterologicznej
dc.affiliationpl
Wydział Lekarski : Zakład Radiologii
dc.contributor.authorpl
Popiela, Tadeusz - 133200
dc.contributor.authorpl
Herman-Sucharska, Irena
dc.contributor.authorpl
Kleinrok, Krzysztof
dc.contributor.authorpl
Urbanik, Andrzej - 133713
dc.contributor.authorpl
Podsiadło-Kleinrok, Beata
dc.contributor.authorpl
Tabor, Jacek
dc.date.accessionpl
2019-06-06
dc.date.accessioned
2019-06-06T07:31:28Z
dc.date.available
2019-06-06T07:31:28Z
dc.date.issuedpl
2007
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 24
dc.description.numberpl
2
dc.description.physicalpl
15-24
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
72
dc.identifier.articleidpl
478058
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/76678
dc.identifier.weblinkpl
http://archiwum.inforadiologia.pl/download/index/idArt/478058.html
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
breast MR
dc.subject.enpl
MR breast biopsy
dc.subject.enpl
MR guided core breast core biopsy
dc.subtypepl
Article
dc.titlepl
Core breast biopsy under MR control : preliminary results
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
1
Views per month
Downloads
popiela_herman-sucharska_kleinrok_urbanik_podsiadlo-kleinrok_tabor_core_breast_biopsy_under_mr_control_2007.pdf
9
popiela_herman-sucharska_kleinrok_urbanik_podsiadlo-kleinrok_tabor_core_breast_biopsy_under_mr_control_2007.odt
3