Patient exposure to X-ray radiation during abdominal aorta and lower limb digital subtraction angiography

2008
journal article
article
dc.abstract.enBackground: The main aim of this study was to find out what is the risk caused by ionizing radiation during digital subtraction angiography (DSA) for abdominal aorta and lower limb examinations. Material\Methods: The study is based on a large group of patient data subjected to a complex analysis of fluoroscopy time, exposure time, air kerma values, and dose-area product (DAP). Measurements were performed on 449 patients with intra-arterial (IA DSA) contrast administration. Results and Median DAP value for fluoroscopy was 5.4 Gy-cm2 and for exposure 51.7 Gy-cm2. On exposure the patients received 94% of the total DAP although this examination takes only 0.1% of the total examination time. For this reason, small changes in the exposure time may result in a considerable reduction in the radiation received by the patient. There was good correlation between DAP values and the fluoroscopy time (r=0.78), while the correlation between DAP and the exposure time was much poorer (r=0.39). It was also found that gender was a differentiating factor neither both fluoroscopy (F[1, 449]=0.01, p>0.05) nor exposure time (F[1, 449]=0.42, p>0.05).pl
dc.contributor.authorJuszkat, Robertpl
dc.contributor.authorBłaszak, Madgalena A.pl
dc.contributor.authorMajewska, Nataliapl
dc.contributor.authorMajewski, Wacławpl
dc.date.accession2019-05-17pl
dc.date.accessioned2019-05-17T08:43:45Z
dc.date.available2019-05-17T08:43:45Z
dc.date.issued2008pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 24pl
dc.description.number3pl
dc.description.physical21-24pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume73pl
dc.identifier.articleid866865pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/75024
dc.identifier.weblinkhttp://archiwum.inforadiologia.pl/download/index/idArt/866865.htmlpl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.endosimetrypl
dc.subject.enradiationpl
dc.subject.endosepl
dc.subtypeArticlepl
dc.titlePatient exposure to X-ray radiation during abdominal aorta and lower limb digital subtraction angiographypl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: The main aim of this study was to find out what is the risk caused by ionizing radiation during digital subtraction angiography (DSA) for abdominal aorta and lower limb examinations. Material\Methods: The study is based on a large group of patient data subjected to a complex analysis of fluoroscopy time, exposure time, air kerma values, and dose-area product (DAP). Measurements were performed on 449 patients with intra-arterial (IA DSA) contrast administration. Results and Median DAP value for fluoroscopy was 5.4 Gy-cm2 and for exposure 51.7 Gy-cm2. On exposure the patients received 94% of the total DAP although this examination takes only 0.1% of the total examination time. For this reason, small changes in the exposure time may result in a considerable reduction in the radiation received by the patient. There was good correlation between DAP values and the fluoroscopy time (r=0.78), while the correlation between DAP and the exposure time was much poorer (r=0.39). It was also found that gender was a differentiating factor neither both fluoroscopy (F[1, 449]=0.01, p>0.05) nor exposure time (F[1, 449]=0.42, p>0.05).
dc.contributor.authorpl
Juszkat, Robert
dc.contributor.authorpl
Błaszak, Madgalena A.
dc.contributor.authorpl
Majewska, Natalia
dc.contributor.authorpl
Majewski, Wacław
dc.date.accessionpl
2019-05-17
dc.date.accessioned
2019-05-17T08:43:45Z
dc.date.available
2019-05-17T08:43:45Z
dc.date.issuedpl
2008
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 24
dc.description.numberpl
3
dc.description.physicalpl
21-24
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
73
dc.identifier.articleidpl
866865
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/75024
dc.identifier.weblinkpl
http://archiwum.inforadiologia.pl/download/index/idArt/866865.html
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
dosimetry
dc.subject.enpl
radiation
dc.subject.enpl
dose
dc.subtypepl
Article
dc.titlepl
Patient exposure to X-ray radiation during abdominal aorta and lower limb digital subtraction angiography
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
1
Views per month
Views per city
San Jose
1
Downloads
juszkat_blaszak_majewska_majewski_patient_exposure_to_x-ray_radiation_2008.pdf
14
juszkat_blaszak_majewska_majewski_patient_exposure_to_x-ray_radiation_2008.odt
4