The utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCC

2018
journal article
article
7
cris.lastimport.wos2024-04-09T22:43:41Z
dc.abstract.enPurpose: To evaluate the diffusion properties of clear cell renal cell carcinoma (ccRCC) on magnetic resonance imaging (MRI) concerning their Fuhrman nuclear grades and sizes, and to compare the diagnostic performance of two ROI placement techniques for apparent diffusion coefficient (ADC) measurement (entire mass vs. only the darkest region of the mass). Material and methods: Fifty-one ccRCC were enrolled in the study and grouped into low-grade ccRCC (Fuhrman grade 1 and 2, n = 37) and high-grade ccRCC (Fuhrman grade 3 and 4, n = 14). Selective ADC (Sel-ADC) measurement was performed by placing a circular ROI that included the darkest region of the tumour on ADC map images. Extensive ADC (Ext-ADC) measurement was performed by drawing an ROI that covered the entire tumour. Results: The Sel-ADC value was lower in high-grade ccRCC (p = 0.019), whereas the Ext-ADC value did not show a statistically significant difference (p = 0.42). Sel-ADC value of a ≤ 1.405 mm2/s has a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy value of 78.6, 72.2, 73.87, 77.13, and 75.4, respectively, to differentiate high-grade from low-grade ccRCC. The size and Fuhrman grade of the ccRCC were inversely correlated with the Sel-ADC value; however, the correlations were weak (r = -0.322, p = 0.021 and r = -0.376, p = 0.006, respectively). There was no difference between ADC values of small (≤ 4 cm) and large (> 4 cm) ccRCCs. Conclusions: The ADC value of the darkest region in solid part of the ccRCC may play a role in predicting the nuclear grade of ccRCC.pl
dc.contributor.authorAslan, Ahmetpl
dc.contributor.authorİnan, İbrahimpl
dc.contributor.authorAktan, Ahmetpl
dc.contributor.authorAyaz, Ercanpl
dc.contributor.authorAslan, Minepl
dc.contributor.authorÖzkanlı, Sıdıka Şeymapl
dc.contributor.authorYildirim, Asifpl
dc.contributor.authorYıkılmaz, Alipl
dc.date.accessioned2018-12-06T08:47:19Z
dc.date.available2018-12-06T08:47:19Z
dc.date.issued2018pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e451pl
dc.description.physicale446-e451pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume83pl
dc.identifier.doi10.5114/pjr.2018.80207pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/62750
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enmagnetic resonance imagingpl
dc.subject.enapparent diffusion coefficientpl
dc.subject.enclear cell renal cell carcinomapl
dc.subject.endiffusion-weighted imagingpl
dc.subject.enFuhrman grading systempl
dc.subtypeArticlepl
dc.titleThe utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCCpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T22:43:41Z
dc.abstract.enpl
Purpose: To evaluate the diffusion properties of clear cell renal cell carcinoma (ccRCC) on magnetic resonance imaging (MRI) concerning their Fuhrman nuclear grades and sizes, and to compare the diagnostic performance of two ROI placement techniques for apparent diffusion coefficient (ADC) measurement (entire mass vs. only the darkest region of the mass). Material and methods: Fifty-one ccRCC were enrolled in the study and grouped into low-grade ccRCC (Fuhrman grade 1 and 2, n = 37) and high-grade ccRCC (Fuhrman grade 3 and 4, n = 14). Selective ADC (Sel-ADC) measurement was performed by placing a circular ROI that included the darkest region of the tumour on ADC map images. Extensive ADC (Ext-ADC) measurement was performed by drawing an ROI that covered the entire tumour. Results: The Sel-ADC value was lower in high-grade ccRCC (p = 0.019), whereas the Ext-ADC value did not show a statistically significant difference (p = 0.42). Sel-ADC value of a ≤ 1.405 mm2/s has a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy value of 78.6, 72.2, 73.87, 77.13, and 75.4, respectively, to differentiate high-grade from low-grade ccRCC. The size and Fuhrman grade of the ccRCC were inversely correlated with the Sel-ADC value; however, the correlations were weak (r = -0.322, p = 0.021 and r = -0.376, p = 0.006, respectively). There was no difference between ADC values of small (≤ 4 cm) and large (> 4 cm) ccRCCs. Conclusions: The ADC value of the darkest region in solid part of the ccRCC may play a role in predicting the nuclear grade of ccRCC.
dc.contributor.authorpl
Aslan, Ahmet
dc.contributor.authorpl
İnan, İbrahim
dc.contributor.authorpl
Aktan, Ahmet
dc.contributor.authorpl
Ayaz, Ercan
dc.contributor.authorpl
Aslan, Mine
dc.contributor.authorpl
Özkanlı, Sıdıka Şeyma
dc.contributor.authorpl
Yildirim, Asif
dc.contributor.authorpl
Yıkılmaz, Ali
dc.date.accessioned
2018-12-06T08:47:19Z
dc.date.available
2018-12-06T08:47:19Z
dc.date.issuedpl
2018
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e451
dc.description.physicalpl
e446-e451
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
83
dc.identifier.doipl
10.5114/pjr.2018.80207
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/62750
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
magnetic resonance imaging
dc.subject.enpl
apparent diffusion coefficient
dc.subject.enpl
clear cell renal cell carcinoma
dc.subject.enpl
diffusion-weighted imaging
dc.subject.enpl
Fuhrman grading system
dc.subtypepl
Article
dc.titlepl
The utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCC
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
10
Views per month
Views per city
Hong Kong
6
Ashburn
1
Downloads
aslan_inan_aktan_ayaz_aslan_ozkanli_yildirim_yikilmaz_the_utility_of_adc_measurement_techniques_2018.pdf
12
aslan_inan_aktan_ayaz_aslan_ozkanli_yildirim_yikilmaz_the_utility_of_adc_measurement_techniques_2018.odt
7