Number of active detector rows and quality of image in computed tomography

2010
journal article
other documents
dc.abstract.enBackground: Rapid technical development of Computed Tomography (CT) means usage the modern, fast scanners which possibilities are not always known by users. A common conviction is the high number of detectors is equivalent to an accurate investigation of sub-millimetre slices of patient body and detection of such small-size lesions. Aim of the paper was to compare an imaging possibilities of the two CT scanners of the same vendors which differ only the configuration of detectors in use. (The group of 48 rows of detector is physically the same for the both scanners.) Material/Methods: Quality of images was controlled using Catphan series 500. The high- contrast resolution, lowcontrast resolution and signal-to-noise ratio were evaluated for images recorded at the constant reconstruction thickness of 5 mm. Results: A precision of imaging was evaluated on the basis signal-to-noise ratio (SNR) in relation to CT Dose Index. The lowest SNR at satisfying visualisation of the low-contrast objects was slightly above 5. The corresponding CT Dose Index was over 5mGy. Care-dose option decreases SNR to nearly 2 what follows unacceptable visualisation of low-contrast objects. Conclusions: on the basis the results for the both scanners was found that high number of active detector rows help to achieve a better visualisation of low-contrast objects under condition of higher CT Dose Index values. The space resolution does not change with the detector configuration.pl
dc.contributor.authorChruściak, Dariuszpl
dc.contributor.authorStaniszewska, Maria A.pl
dc.date.accession2018-10-11pl
dc.date.accessioned2018-10-11T13:03:10Z
dc.date.available2018-10-11T13:03:10Z
dc.date.issued2010pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.number3pl
dc.description.physical81-86pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume75pl
dc.identifier.articleid881457pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/57908
dc.identifier.weblinkhttp://archiwum.polradiol.com/abstract/index/idArt/881457pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subtypeOtherDocumentspl
dc.titleNumber of active detector rows and quality of image in computed tomographypl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: Rapid technical development of Computed Tomography (CT) means usage the modern, fast scanners which possibilities are not always known by users. A common conviction is the high number of detectors is equivalent to an accurate investigation of sub-millimetre slices of patient body and detection of such small-size lesions. Aim of the paper was to compare an imaging possibilities of the two CT scanners of the same vendors which differ only the configuration of detectors in use. (The group of 48 rows of detector is physically the same for the both scanners.) Material/Methods: Quality of images was controlled using Catphan series 500. The high- contrast resolution, lowcontrast resolution and signal-to-noise ratio were evaluated for images recorded at the constant reconstruction thickness of 5 mm. Results: A precision of imaging was evaluated on the basis signal-to-noise ratio (SNR) in relation to CT Dose Index. The lowest SNR at satisfying visualisation of the low-contrast objects was slightly above 5. The corresponding CT Dose Index was over 5mGy. Care-dose option decreases SNR to nearly 2 what follows unacceptable visualisation of low-contrast objects. Conclusions: on the basis the results for the both scanners was found that high number of active detector rows help to achieve a better visualisation of low-contrast objects under condition of higher CT Dose Index values. The space resolution does not change with the detector configuration.
dc.contributor.authorpl
Chruściak, Dariusz
dc.contributor.authorpl
Staniszewska, Maria A.
dc.date.accessionpl
2018-10-11
dc.date.accessioned
2018-10-11T13:03:10Z
dc.date.available
2018-10-11T13:03:10Z
dc.date.issuedpl
2010
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.numberpl
3
dc.description.physicalpl
81-86
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
75
dc.identifier.articleidpl
881457
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/57908
dc.identifier.weblinkpl
http://archiwum.polradiol.com/abstract/index/idArt/881457
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subtypepl
OtherDocuments
dc.titlepl
Number of active detector rows and quality of image in computed tomography
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
2
Views per month
Views per city
San Jose
1
Downloads
chrusciak_staniszewska_number_of_active_detector_rows_and_quality_of_image_2010.pdf
65
chrusciak_staniszewska_number_of_active_detector_rows_and_quality_of_image_2010.odt
3