Preoperative ultrasonographic examination of the radial artery and the cephalic vein and risks of dialysis arterio-venous fistula dysfunction

2010
journal article
article
dc.abstract.enBackground: Hemodialysis used as renal replacement therapy requires a well-functioning vascular access. Arterio-venous fistula (AVF) created on the forearm is the best vascular access, but it also reveals numerous complications such as: lack of fistula maturation and hemodynamically significant stenoses. Many risk factors of fistula dysfunction are still not identified. Material/Methods: Radial artery and cephalic vein diameter and patency were ultrasonographically examined before forearm AVF creation. Intima-media complex width, blood flow and peak systolic velocity in distal part of radial artery were measured. Presence of thrombosis and post-inflammatory changes in cephalic vein were also checked. Forearm AVF was created in 66 patients. Fistula US examination was performed 3 and 12 months after operation with measurement of vessel diameter and blood flow. Fistula patency was observed in 24 months after creation. Comparison of pre- and postoperative US examinations between groups with well functioning and thrombosed fistulas was performed. Results: Primary patency of forearm AVF after 12 and 24 months was 65.2% and 53.0%, respectively. Patients with well functioning forearm AVF have significantly bigger cephalic vein diameter and peak systolic velocity in radial artery. We did not observe significant influence of radial artery intima-media complex width and radial artery diameter on AVF function. In postoperative examination, fistula diameter and flow significantly influenced the risk of AVF thrombosis. Conclusions: US examination of radial artery and cephalic vein performed before forearm AVF creation enables identification of patients with greater risk of fistula dysfunction. Cephalic vein diameter and peak systolic velocity are prognostic factors of fistula function. Control postoperative US examination of forearm fistula enables detection of AVF at risk of thrombosis.pl
dc.contributor.authorBojakowski, Krzysztofpl
dc.contributor.authorGorczyca-Wiśniewska, Ewapl
dc.contributor.authorSzatkowski, Maciejpl
dc.contributor.authorWalecki, Jerzypl
dc.contributor.authorAndziak, Piotrpl
dc.date.accession2018-09-28pl
dc.date.accessioned2018-09-28T11:14:45Z
dc.date.available2018-09-28T11:14:45Z
dc.date.issued2010pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 12pl
dc.description.number1pl
dc.description.physical7-12pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume75pl
dc.identifier.articleid878427pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/57517
dc.identifier.weblinkhttp://archiwum.polradiol.com/abstract/index/idArt/878427pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enultrasonographic examinationpl
dc.subject.enrisk factorpl
dc.subject.enarterio-venous fistulapl
dc.subtypeArticlepl
dc.titlePreoperative ultrasonographic examination of the radial artery and the cephalic vein and risks of dialysis arterio-venous fistula dysfunctionpl
dc.title.alternativePrzedoperacyjna ultrasonograficzna ocena tętnicy promieniowej i żyły odpromieniowej a ryzyko wystąpienia zaburzeń funkcjonowania przetok tętniczo-żylnych wytworzonych dla celów dializoterapiipl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: Hemodialysis used as renal replacement therapy requires a well-functioning vascular access. Arterio-venous fistula (AVF) created on the forearm is the best vascular access, but it also reveals numerous complications such as: lack of fistula maturation and hemodynamically significant stenoses. Many risk factors of fistula dysfunction are still not identified. Material/Methods: Radial artery and cephalic vein diameter and patency were ultrasonographically examined before forearm AVF creation. Intima-media complex width, blood flow and peak systolic velocity in distal part of radial artery were measured. Presence of thrombosis and post-inflammatory changes in cephalic vein were also checked. Forearm AVF was created in 66 patients. Fistula US examination was performed 3 and 12 months after operation with measurement of vessel diameter and blood flow. Fistula patency was observed in 24 months after creation. Comparison of pre- and postoperative US examinations between groups with well functioning and thrombosed fistulas was performed. Results: Primary patency of forearm AVF after 12 and 24 months was 65.2% and 53.0%, respectively. Patients with well functioning forearm AVF have significantly bigger cephalic vein diameter and peak systolic velocity in radial artery. We did not observe significant influence of radial artery intima-media complex width and radial artery diameter on AVF function. In postoperative examination, fistula diameter and flow significantly influenced the risk of AVF thrombosis. Conclusions: US examination of radial artery and cephalic vein performed before forearm AVF creation enables identification of patients with greater risk of fistula dysfunction. Cephalic vein diameter and peak systolic velocity are prognostic factors of fistula function. Control postoperative US examination of forearm fistula enables detection of AVF at risk of thrombosis.
dc.contributor.authorpl
Bojakowski, Krzysztof
dc.contributor.authorpl
Gorczyca-Wiśniewska, Ewa
dc.contributor.authorpl
Szatkowski, Maciej
dc.contributor.authorpl
Walecki, Jerzy
dc.contributor.authorpl
Andziak, Piotr
dc.date.accessionpl
2018-09-28
dc.date.accessioned
2018-09-28T11:14:45Z
dc.date.available
2018-09-28T11:14:45Z
dc.date.issuedpl
2010
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 12
dc.description.numberpl
1
dc.description.physicalpl
7-12
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
75
dc.identifier.articleidpl
878427
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/57517
dc.identifier.weblinkpl
http://archiwum.polradiol.com/abstract/index/idArt/878427
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
ultrasonographic examination
dc.subject.enpl
risk factor
dc.subject.enpl
arterio-venous fistula
dc.subtypepl
Article
dc.titlepl
Preoperative ultrasonographic examination of the radial artery and the cephalic vein and risks of dialysis arterio-venous fistula dysfunction
dc.title.alternativepl
Przedoperacyjna ultrasonograficzna ocena tętnicy promieniowej i żyły odpromieniowej a ryzyko wystąpienia zaburzeń funkcjonowania przetok tętniczo-żylnych wytworzonych dla celów dializoterapii
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
1
Views per month
Views per city
San Jose
1
Downloads
bojakowski_gorczyca-wisniewska_szatkowski_walecki_andziak_preoperative_ultrasonographic_examination_of_the_radial_artery_2010.odt
11
bojakowski_gorczyca-wisniewska_szatkowski_walecki_andziak_preoperative_ultrasonographic_examination_of_the_radial_artery_2010.pdf
10