Normal dimensions of trachea and two main bronchi in the Iranian population

2011
journal article
article
dc.abstract.enBackground: The purpose of this study was to determine the normal diameters of larger airways in the Persian population, since these demographic variables are essential for interpretation of chest CTs and/or plain X-rays. Material/Methods: During a 6-month period, sagittal and coronal diameters of tracheas of all cases admitted for a chest CT to the radiology department of the National Research Institute of Tuberculosis and Lung Disease (NRITLD) were measured. The patients had to accept to take part in the study and had to fulfill the inclusion and exclusion criteria of the study. Ninety-nine percent confidence intervals (99% CI) were used to define the upper and lower limits of normal. Results: Two hundred subjects, including 132 men and 68 women aged 20-85 years, were studied. Coronal and sagittal diameters of tracheas in the upper part were as follows: 1.8±0.24 and 2.06±0.27cm for men, and 1.48±0.20 and 1.49±0.24 for women, respectively. For the lower part that was: 1.8±0.23, 1.86±0.27, 1.51±0.18, and 1.46±0.23, respectively. For the right and left mainstem bronchi the values were as follows: 1.16±0.17 and 1.02±0.22 for men and 0.93±0.13 and 0.81±0.13 for women, respectively. Conclusions: The values determined by us had a narrower range of normality than the ones found in the previous reports, so they will stay more friendly for interpretation of individual cases.pl
dc.contributor.authorZahedi-Nejad, Ninapl
dc.contributor.authorBakhshayesh-Karam, Mehrdadpl
dc.contributor.authorKahkoei, Shahrampl
dc.contributor.authorAbbasi-Dezfoully, Azizolapl
dc.contributor.authorMasjedi, Mohammad Rezapl
dc.date.accession2018-09-18pl
dc.date.accessioned2018-09-18T08:08:09Z
dc.date.available2018-09-18T08:08:09Z
dc.date.issued2011pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 31pl
dc.description.number4pl
dc.description.physical28-31pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume76pl
dc.identifier.articleid882141pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/57028
dc.identifier.weblinkhttp://archiwum.polradiol.com/abstract/index/idArt/882141pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enanatomypl
dc.subject.entracheapl
dc.subject.enbronchipl
dc.subject.ennormalpl
dc.subject.enCTpl
dc.subtypeArticlepl
dc.titleNormal dimensions of trachea and two main bronchi in the Iranian populationpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: The purpose of this study was to determine the normal diameters of larger airways in the Persian population, since these demographic variables are essential for interpretation of chest CTs and/or plain X-rays. Material/Methods: During a 6-month period, sagittal and coronal diameters of tracheas of all cases admitted for a chest CT to the radiology department of the National Research Institute of Tuberculosis and Lung Disease (NRITLD) were measured. The patients had to accept to take part in the study and had to fulfill the inclusion and exclusion criteria of the study. Ninety-nine percent confidence intervals (99% CI) were used to define the upper and lower limits of normal. Results: Two hundred subjects, including 132 men and 68 women aged 20-85 years, were studied. Coronal and sagittal diameters of tracheas in the upper part were as follows: 1.8±0.24 and 2.06±0.27cm for men, and 1.48±0.20 and 1.49±0.24 for women, respectively. For the lower part that was: 1.8±0.23, 1.86±0.27, 1.51±0.18, and 1.46±0.23, respectively. For the right and left mainstem bronchi the values were as follows: 1.16±0.17 and 1.02±0.22 for men and 0.93±0.13 and 0.81±0.13 for women, respectively. Conclusions: The values determined by us had a narrower range of normality than the ones found in the previous reports, so they will stay more friendly for interpretation of individual cases.
dc.contributor.authorpl
Zahedi-Nejad, Nina
dc.contributor.authorpl
Bakhshayesh-Karam, Mehrdad
dc.contributor.authorpl
Kahkoei, Shahram
dc.contributor.authorpl
Abbasi-Dezfoully, Azizola
dc.contributor.authorpl
Masjedi, Mohammad Reza
dc.date.accessionpl
2018-09-18
dc.date.accessioned
2018-09-18T08:08:09Z
dc.date.available
2018-09-18T08:08:09Z
dc.date.issuedpl
2011
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 31
dc.description.numberpl
4
dc.description.physicalpl
28-31
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
76
dc.identifier.articleidpl
882141
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/57028
dc.identifier.weblinkpl
http://archiwum.polradiol.com/abstract/index/idArt/882141
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
anatomy
dc.subject.enpl
trachea
dc.subject.enpl
bronchi
dc.subject.enpl
normal
dc.subject.enpl
CT
dc.subtypepl
Article
dc.titlepl
Normal dimensions of trachea and two main bronchi in the Iranian population
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
2
Views per month
Views per city
Highlands Ranch
1
Downloads
zahedi-nejad_bakhshayesh-karam_kahkoei_abbasi-dezfoully_masjedi_normal_dimensions_of_trachea_and_two_main_bronchi_2011.pdf
15
zahedi-nejad_bakhshayesh-karam_kahkoei_abbasi-dezfoully_masjedi_normal_dimensions_of_trachea_and_two_main_bronchi_2011.odt
5