Single photon emission computed tomography as a diagnostic method in ischemic heart disease : basic technical aspects
2011
journal article
review article
Journal
Polish Journal of Radiology
Author
Pleśniak Jarosław
Volume
76
Number
3
Pages
49-52
Article ID
881952
ISSN
1733-134X
eISSN
1899-0967
Keywords in English
SPECT
mTc-MIBI
myocardial perfusion
Access date
2018-08-30
Remarks
Bibilogr. s. 52
Language
English
Journal language
English
Abstract in English
Ischemic Heart Disease (IHD) poses an important diagnostic problem. Clinical picture of the disease is often atypical. SPECT is one of the main diagnostic tools in ischemic heart disease. Radioisotope study evaluates distribution of a radiopharmaceutical agent in the heart through a series of scintigraphic images taken by an external gamma camera. This article discusses the technical aspects of cardiac SPECT imaging, starting with a detection system, through image reconstruction, and ending with image filtering.
dc.abstract.en | Ischemic Heart Disease (IHD) poses an important diagnostic problem. Clinical picture of the disease is often atypical. SPECT is one of the main diagnostic tools in ischemic heart disease. Radioisotope study evaluates distribution of a radiopharmaceutical agent in the heart through a series of scintigraphic images taken by an external gamma camera. This article discusses the technical aspects of cardiac SPECT imaging, starting with a detection system, through image reconstruction, and ending with image filtering. | pl |
dc.contributor.author | Pleśniak, Jarosław | pl |
dc.date.accession | 2018-08-30 | pl |
dc.date.accessioned | 2018-08-30T11:31:51Z | |
dc.date.available | 2018-08-30T11:31:51Z | |
dc.date.issued | 2011 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibilogr. s. 52 | pl |
dc.description.number | 3 | pl |
dc.description.physical | 49-52 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 76 | pl |
dc.identifier.articleid | 881952 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.project | ROD UJ / OP | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/56542 | |
dc.identifier.weblink | http://archiwum.polradiol.com/abstract/index/idArt/881952 | pl |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | SPECT | pl |
dc.subject.en | mTc-MIBI | pl |
dc.subject.en | myocardial perfusion | pl |
dc.subtype | ReviewArticle | pl |
dc.title | Single photon emission computed tomography as a diagnostic method in ischemic heart disease : basic technical aspects | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
dc.abstract.enpl
Ischemic Heart Disease (IHD) poses an important diagnostic problem. Clinical picture of the disease is often atypical. SPECT is one of the main diagnostic tools in ischemic heart disease. Radioisotope study evaluates distribution of a radiopharmaceutical agent in the heart through a series of scintigraphic images taken by an external gamma camera. This article discusses the technical aspects of cardiac SPECT imaging, starting with a detection system, through image reconstruction, and ending with image filtering. dc.contributor.authorpl
Pleśniak, Jarosław dc.date.accessionpl
2018-08-30 dc.date.accessioned
2018-08-30T11:31:51Z dc.date.available
2018-08-30T11:31:51Z dc.date.issuedpl
2011 dc.date.openaccess
0 dc.description.accesstime
w momencie opublikowania dc.description.additionalpl
Bibilogr. s. 52 dc.description.numberpl
3 dc.description.physicalpl
49-52 dc.description.version
ostateczna wersja wydawcy dc.description.volumepl
76 dc.identifier.articleidpl
881952 dc.identifier.eissnpl
1899-0967 dc.identifier.issnpl
1733-134X dc.identifier.projectpl
ROD UJ / OP dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/56542 dc.identifier.weblinkpl
http://archiwum.polradiol.com/abstract/index/idArt/881952 dc.languagepl
eng dc.language.containerpl
eng dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa dc.rights.licence
CC-BY-NC-ND dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl dc.share.type
otwarte czasopismo dc.subject.enpl
SPECT dc.subject.enpl
mTc-MIBI dc.subject.enpl
myocardial perfusion dc.subtypepl
ReviewArticle dc.titlepl
Single photon emission computed tomography as a diagnostic method in ischemic heart disease : basic technical aspects dc.title.journalpl
Polish Journal of Radiology dc.typepl
JournalArticle dspace.entity.type
Publication Affiliations
No affiliation
Pleśniak, Jarosław
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
2
Views per month
Downloads
plesniak_single_photon_emission_computed_tomography_as_a_diagnostic_method_2011.pdf
8
plesniak_single_photon_emission_computed_tomography_as_a_diagnostic_method_2011.odt
3
Open Access
Loading...