Ultrasound is not useful as a screening tool for dengue fever

2017
journal article
article
6
dc.abstract.enBackground: Dengue fever is a tropical disease that is transmitted by female Aedes Aegypti mosquitos. Early diagnosis is necessary to reduce the mortality and morbidity associated with the disease. A combination of clinical, laboratory, and sonography findings can be potentially helpful in making an early diagnosis of dengue fever. There is paucity of literature on the use of ultrasound for dengue fever screening; hence, the primary objective of the study was to evaluate the utility of ultrasound as a screening tool in dengue fever. Material/Methods: A total of 160 patients of suspected dengue fever were included in the study. They underwent ultrasound examinations in order to search for thickening of the gallbladder wall, pleural effusion, and ascites. On the basis of ultrasound findings, 65 cases were positive and 95 cases were negative for dengue fever. Serological tests were also used for diagnosing dengue fever, 93 cases were seropositive and 67 cases were seronegative. The ultrasonically diagnosed cases were compared with serologically diagnosed cases, and appropriate descriptive statistical analyses were applied. Results: The ultrasound findings included gall bladder wall thickening in 66 patients (41.2%). The sensitivity, specificity, and positive predictive value of ultrasound in diagnosing dengue fever were 58%, 84%, and 83%, respectively. The negative predictive value and accuracy were 59% and 68.8%, respectively. Conclusions: The present study suggests that increased gall bladder wall thickness, pleural effusion, ascites, hepatomegaly, and splenomegaly are highly suggestive of dengue fever in clinically suspected cases. However, ultrasound should not be used as a screening tool, as negative ultrasound findings cannot rule out dengue fever due to the low sensitivity of this examination.pl
dc.contributor.authorParmar, Jitendrapl
dc.contributor.authorMohan, Chanderpl
dc.contributor.authorKumar, G. Prempl
dc.contributor.authorVora, Maulikpl
dc.date.accessioned2018-01-05T10:03:52Z
dc.date.available2018-01-05T10:03:52Z
dc.date.issued2017pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 700pl
dc.description.physical693-700pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume82pl
dc.identifier.doi10.12659/PJR.902861pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/48076
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.endenguepl
dc.subject.enmass screeningpl
dc.subject.enultrasonographypl
dc.subject.enDopplerpl
dc.subject.encolorpl
dc.subtypeArticlepl
dc.titleUltrasound is not useful as a screening tool for dengue feverpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: Dengue fever is a tropical disease that is transmitted by female Aedes Aegypti mosquitos. Early diagnosis is necessary to reduce the mortality and morbidity associated with the disease. A combination of clinical, laboratory, and sonography findings can be potentially helpful in making an early diagnosis of dengue fever. There is paucity of literature on the use of ultrasound for dengue fever screening; hence, the primary objective of the study was to evaluate the utility of ultrasound as a screening tool in dengue fever. Material/Methods: A total of 160 patients of suspected dengue fever were included in the study. They underwent ultrasound examinations in order to search for thickening of the gallbladder wall, pleural effusion, and ascites. On the basis of ultrasound findings, 65 cases were positive and 95 cases were negative for dengue fever. Serological tests were also used for diagnosing dengue fever, 93 cases were seropositive and 67 cases were seronegative. The ultrasonically diagnosed cases were compared with serologically diagnosed cases, and appropriate descriptive statistical analyses were applied. Results: The ultrasound findings included gall bladder wall thickening in 66 patients (41.2%). The sensitivity, specificity, and positive predictive value of ultrasound in diagnosing dengue fever were 58%, 84%, and 83%, respectively. The negative predictive value and accuracy were 59% and 68.8%, respectively. Conclusions: The present study suggests that increased gall bladder wall thickness, pleural effusion, ascites, hepatomegaly, and splenomegaly are highly suggestive of dengue fever in clinically suspected cases. However, ultrasound should not be used as a screening tool, as negative ultrasound findings cannot rule out dengue fever due to the low sensitivity of this examination.
dc.contributor.authorpl
Parmar, Jitendra
dc.contributor.authorpl
Mohan, Chander
dc.contributor.authorpl
Kumar, G. Prem
dc.contributor.authorpl
Vora, Maulik
dc.date.accessioned
2018-01-05T10:03:52Z
dc.date.available
2018-01-05T10:03:52Z
dc.date.issuedpl
2017
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 700
dc.description.physicalpl
693-700
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
82
dc.identifier.doipl
10.12659/PJR.902861
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/48076
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
dengue
dc.subject.enpl
mass screening
dc.subject.enpl
ultrasonography
dc.subject.enpl
Doppler
dc.subject.enpl
color
dc.subtypepl
Article
dc.titlepl
Ultrasound is not useful as a screening tool for dengue fever
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
3
Views per month
Downloads
parmar_mohan_kumar_vora_ultrasound_is_not_useful_as_a_screening_tool_2017.pdf
9