Multidetector computed tomography (CT) in evaluation of congenital cyanotic heart diseases

2017
journal article
article
6
dc.abstract.enBackground: The aim of the study is to emphasize the role of 128 MSCT angiography in the diagnosis of congenital cyanotic heart diseases. Material/Methods: This study included sixty patients and was conducted from December 2014 to July 2016 in the Multidetector CT unit of Zagazig University hospitals. All images included axial, MPR, MIP, and VRT and were interpreted in one session. Pulmonary veins were assessed for PAPVR or TAPVR, PDA, cardiac apex and heart chambers, interatrial or interventricular septal defects, pericardium, and site and size of the great veins (IVC and SVC). Results: This study included 60 patients. Thirty-four were boys (56.7%), and 26 were girls (43.3%). The age ranged from nine months to five years, and the mean age was 34.5 months. We found the following anomalies: tetralogy of Fallot (15 patients, 25%), tricuspid atresia (12 patients, 20%), Ebstein's anomaly (4 patients, 6.5%), pulmonic atresia or stenosis (7 patients, 11.5%), truncus arteriosus (6 patients, 10%), TGA (10 patients, 17%), and TAPVR (6 patients, 10%). Conclusions: MDCT proved to be an important modality for decision-making in patients with congenital cyanotic heart diseases.pl
dc.contributor.authorEnaba, Moanes M.pl
dc.contributor.authorHasan, Doaa I.pl
dc.contributor.authorAlsowey, Ahmed M.pl
dc.contributor.authorElsayed, Hanypl
dc.date.accessioned2018-01-05T08:25:02Z
dc.date.available2018-01-05T08:25:02Z
dc.date.issued2017pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 659pl
dc.description.physical645-659pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume82pl
dc.identifier.doi10.12659/PJR.903222pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/48057
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.encyanosispl
dc.subject.enheart diseasespl
dc.subject.enmultidetector computed tomographypl
dc.subtypeArticlepl
dc.titleMultidetector computed tomography (CT) in evaluation of congenital cyanotic heart diseasespl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: The aim of the study is to emphasize the role of 128 MSCT angiography in the diagnosis of congenital cyanotic heart diseases. Material/Methods: This study included sixty patients and was conducted from December 2014 to July 2016 in the Multidetector CT unit of Zagazig University hospitals. All images included axial, MPR, MIP, and VRT and were interpreted in one session. Pulmonary veins were assessed for PAPVR or TAPVR, PDA, cardiac apex and heart chambers, interatrial or interventricular septal defects, pericardium, and site and size of the great veins (IVC and SVC). Results: This study included 60 patients. Thirty-four were boys (56.7%), and 26 were girls (43.3%). The age ranged from nine months to five years, and the mean age was 34.5 months. We found the following anomalies: tetralogy of Fallot (15 patients, 25%), tricuspid atresia (12 patients, 20%), Ebstein's anomaly (4 patients, 6.5%), pulmonic atresia or stenosis (7 patients, 11.5%), truncus arteriosus (6 patients, 10%), TGA (10 patients, 17%), and TAPVR (6 patients, 10%). Conclusions: MDCT proved to be an important modality for decision-making in patients with congenital cyanotic heart diseases.
dc.contributor.authorpl
Enaba, Moanes M.
dc.contributor.authorpl
Hasan, Doaa I.
dc.contributor.authorpl
Alsowey, Ahmed M.
dc.contributor.authorpl
Elsayed, Hany
dc.date.accessioned
2018-01-05T08:25:02Z
dc.date.available
2018-01-05T08:25:02Z
dc.date.issuedpl
2017
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 659
dc.description.physicalpl
645-659
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
82
dc.identifier.doipl
10.12659/PJR.903222
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/48057
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
cyanosis
dc.subject.enpl
heart diseases
dc.subject.enpl
multidetector computed tomography
dc.subtypepl
Article
dc.titlepl
Multidetector computed tomography (CT) in evaluation of congenital cyanotic heart diseases
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
4
Views per month
Views per city
Ashburn
2
Downloads
enaba_hasan_alsowey_elsayed_multidetector_computed_tomography_ct_in_evaluation_2017.pdf
8