Accuracy of artificial intelligence in the detection and segmentation of oral and maxillofacial structures using cone-beam computed tomography images : a systematic review and meta-analysis

2023
journal article
review article
13
cris.lastimport.wos2024-04-09T23:07:32Z
dc.abstract.enPurpose: The aim of the present systematic review and meta-analysis was to resolve the conflicts on the diagnostic accuracy of artificial intelligence systems in detecting and segmenting oral and maxillofacial structures using conebeam computed tomography (CBCT) images. Material and methods: We performed a literature search of the Embase, PubMed, and Scopus databases for reports published from their inception to 31 October 2022. We included studies that explored the accuracy of artificial intelligence in the automatic detection or segmentation of oral and maxillofacial anatomical landmarks or lesions using CBCT images. The extracted data were pooled, and the estimates were presented with 95% confidence intervals (CIs). Results: In total, 19 eligible studies were identified. As per the analysis, the overall pooled diagnostic accuracy of artificial intelligence was 0.93 (95% CI: 0.91-0.94). This rate was 0.93 (95% CI: 0.89-0.96) for anatomical landmarks based on 7 studies and 0.92 (95% CI: 0.90-0.94) for lesions according to 12 reports. Moreover, the pooled accuracy of detection and segmentation tasks for artificial intelligence was 0.93 (95% CI: 0.91-0.94) and 0.92 (95% CI: 0.85-0.95) based on 14 and 5 surveys, respectively. Conclusions: Excellent accuracy was observed for the detection and segmentation objectives of artificial intelligence using oral and maxillofacial CBCT images. These systems have the potential to streamline oral and dental healthcare services.pl
dc.contributor.authorAbesi, Faridapl
dc.contributor.authorJamali, Atena Sadatpl
dc.contributor.authorZamani, Mohammadpl
dc.date.accessioned2023-06-05T10:08:25Z
dc.date.available2023-06-05T10:08:25Z
dc.date.issued2023pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e262-e263pl
dc.description.physicale256-e263pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume88pl
dc.identifier.doi10.5114/pjr.2023.127624pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/312004
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enartificial intelligencepl
dc.subject.encone-beam computed tomographypl
dc.subject.endiagnosispl
dc.subject.endentistrypl
dc.subtypeReviewArticlepl
dc.titleAccuracy of artificial intelligence in the detection and segmentation of oral and maxillofacial structures using cone-beam computed tomography images : a systematic review and meta-analysispl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T23:07:32Z
dc.abstract.enpl
Purpose: The aim of the present systematic review and meta-analysis was to resolve the conflicts on the diagnostic accuracy of artificial intelligence systems in detecting and segmenting oral and maxillofacial structures using conebeam computed tomography (CBCT) images. Material and methods: We performed a literature search of the Embase, PubMed, and Scopus databases for reports published from their inception to 31 October 2022. We included studies that explored the accuracy of artificial intelligence in the automatic detection or segmentation of oral and maxillofacial anatomical landmarks or lesions using CBCT images. The extracted data were pooled, and the estimates were presented with 95% confidence intervals (CIs). Results: In total, 19 eligible studies were identified. As per the analysis, the overall pooled diagnostic accuracy of artificial intelligence was 0.93 (95% CI: 0.91-0.94). This rate was 0.93 (95% CI: 0.89-0.96) for anatomical landmarks based on 7 studies and 0.92 (95% CI: 0.90-0.94) for lesions according to 12 reports. Moreover, the pooled accuracy of detection and segmentation tasks for artificial intelligence was 0.93 (95% CI: 0.91-0.94) and 0.92 (95% CI: 0.85-0.95) based on 14 and 5 surveys, respectively. Conclusions: Excellent accuracy was observed for the detection and segmentation objectives of artificial intelligence using oral and maxillofacial CBCT images. These systems have the potential to streamline oral and dental healthcare services.
dc.contributor.authorpl
Abesi, Farida
dc.contributor.authorpl
Jamali, Atena Sadat
dc.contributor.authorpl
Zamani, Mohammad
dc.date.accessioned
2023-06-05T10:08:25Z
dc.date.available
2023-06-05T10:08:25Z
dc.date.issuedpl
2023
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e262-e263
dc.description.physicalpl
e256-e263
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
88
dc.identifier.doipl
10.5114/pjr.2023.127624
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/312004
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
artificial intelligence
dc.subject.enpl
cone-beam computed tomography
dc.subject.enpl
diagnosis
dc.subject.enpl
dentistry
dc.subtypepl
ReviewArticle
dc.titlepl
Accuracy of artificial intelligence in the detection and segmentation of oral and maxillofacial structures using cone-beam computed tomography images : a systematic review and meta-analysis
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
3
Views per month
Views per city
San Jose
1
Turza Wielka
1
Downloads
abesi_jamali_zamani_accuracy_of_artificial_intelligence_in_the_detection_and_segmentation_2023.pdf
16