Validation of exophthalmos magnetic resonance imaging measurements in patients with Graves’ orbitopathy, compared to ophthalmometry results

2022
journal article
article
3
cris.lastimport.wos2024-04-09T20:59:40Z
dc.abstract.enPurpose: Although assessment of the orbital structures using magnetic resonance imaging (MRI) is well described in the literature, there is no consensus as to which measurement method is the most useful in exophthalmos assessment. The aim of the study was to correlate 2 MRI methods of exophthalmos measurement with exophthalmometry results and to determine a proper technique of exophthalmos measurement. Material and methods: Fifty-four patients (108 orbits) with exophthalmos in the course of Graves’ orbitopathy were enrolled in the study. Two measurements on axial T2W orbital MRI images were performed by 2 independent radiologists: the distance from the interzygomatic line to the anterior surface of the globe (AD) and the distance from the interzygomatic line to the posterior sclera (PD). Within 4 weeks, an exophthalmometry was performed by an ophthalmologist using a Hertel exophthalmometer. The inter-observer variation was assessed using the Pearson correlation coefficient. Values were presented as mean and standard deviation, and the differences in values were explored with Student’s t-test. Results: The mean AD measured on MRI by the first observer was 20.6 ± 3 mm, and 20.6 ± 2.9 mm by the second observer. PD values were 2.9 ± 2.8 mm and 3.4 ± 2.8 mm, respectively. The mean exophthalmometry result was 21 ± 3.3 mm. The correlation was very high between observers for AD measurements (r = 0.98, p = 0.01) and high for PD measurements (r = 0.95, p = 0.01). AD measurements on MRI and exophthalmometry results were strongly correlated (r = 0.9, p = 0.01). Conclusions: The AD measurement has better reproducibility and is directly correlated with Hertel exophthalmometry. This method could be sufficient in routine practice.pl
dc.contributor.authorWnuk, Emiliapl
dc.contributor.authorMaj, Edytapl
dc.contributor.authorJabłońska-Pawlak, Annapl
dc.contributor.authorJeczeń, Mariapl
dc.contributor.authorRowińska-Berman, Katarzynapl
dc.contributor.authorRowiński, Olgierdpl
dc.date.accessioned2023-04-12T12:18:10Z
dc.date.available2023-04-12T12:18:10Z
dc.date.issued2022pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e543-e544pl
dc.description.physicale539-e544pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume87pl
dc.identifier.doi10.5114/pjr.2022.119939pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/310271
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enexophthalmospl
dc.subject.enproptosispl
dc.subject.enHertel exophthalmometrypl
dc.subject.enGraves' orbitopathypl
dc.subject.enthyroid-associated orbitopathypl
dc.subject.enMRIpl
dc.subtypeArticlepl
dc.titleValidation of exophthalmos magnetic resonance imaging measurements in patients with Graves’ orbitopathy, compared to ophthalmometry resultspl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T20:59:40Z
dc.abstract.enpl
Purpose: Although assessment of the orbital structures using magnetic resonance imaging (MRI) is well described in the literature, there is no consensus as to which measurement method is the most useful in exophthalmos assessment. The aim of the study was to correlate 2 MRI methods of exophthalmos measurement with exophthalmometry results and to determine a proper technique of exophthalmos measurement. Material and methods: Fifty-four patients (108 orbits) with exophthalmos in the course of Graves’ orbitopathy were enrolled in the study. Two measurements on axial T2W orbital MRI images were performed by 2 independent radiologists: the distance from the interzygomatic line to the anterior surface of the globe (AD) and the distance from the interzygomatic line to the posterior sclera (PD). Within 4 weeks, an exophthalmometry was performed by an ophthalmologist using a Hertel exophthalmometer. The inter-observer variation was assessed using the Pearson correlation coefficient. Values were presented as mean and standard deviation, and the differences in values were explored with Student’s t-test. Results: The mean AD measured on MRI by the first observer was 20.6 ± 3 mm, and 20.6 ± 2.9 mm by the second observer. PD values were 2.9 ± 2.8 mm and 3.4 ± 2.8 mm, respectively. The mean exophthalmometry result was 21 ± 3.3 mm. The correlation was very high between observers for AD measurements (r = 0.98, p = 0.01) and high for PD measurements (r = 0.95, p = 0.01). AD measurements on MRI and exophthalmometry results were strongly correlated (r = 0.9, p = 0.01). Conclusions: The AD measurement has better reproducibility and is directly correlated with Hertel exophthalmometry. This method could be sufficient in routine practice.
dc.contributor.authorpl
Wnuk, Emilia
dc.contributor.authorpl
Maj, Edyta
dc.contributor.authorpl
Jabłońska-Pawlak, Anna
dc.contributor.authorpl
Jeczeń, Maria
dc.contributor.authorpl
Rowińska-Berman, Katarzyna
dc.contributor.authorpl
Rowiński, Olgierd
dc.date.accessioned
2023-04-12T12:18:10Z
dc.date.available
2023-04-12T12:18:10Z
dc.date.issuedpl
2022
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e543-e544
dc.description.physicalpl
e539-e544
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
87
dc.identifier.doipl
10.5114/pjr.2022.119939
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/310271
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
exophthalmos
dc.subject.enpl
proptosis
dc.subject.enpl
Hertel exophthalmometry
dc.subject.enpl
Graves' orbitopathy
dc.subject.enpl
thyroid-associated orbitopathy
dc.subject.enpl
MRI
dc.subtypepl
Article
dc.titlepl
Validation of exophthalmos magnetic resonance imaging measurements in patients with Graves’ orbitopathy, compared to ophthalmometry results
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
2
Views per month
Views per city
San Jose
1
Sopot
1
Downloads
wnuk_et-al_validation_of_exophthalmos_magnetic_resonance_imaging_measurements_2022.pdf
138