Simple view
Full metadata view
Authors
Statistics
Validation of exophthalmos magnetic resonance imaging measurements in patients with Graves’ orbitopathy, compared to ophthalmometry results
exophthalmos
proptosis
Hertel exophthalmometry
Graves' orbitopathy
thyroid-associated orbitopathy
MRI
Bibliogr. s. e543-e544
Purpose: Although assessment of the orbital structures using magnetic resonance imaging (MRI) is well described in the literature, there is no consensus as to which measurement method is the most useful in exophthalmos assessment. The aim of the study was to correlate 2 MRI methods of exophthalmos measurement with exophthalmometry results and to determine a proper technique of exophthalmos measurement. Material and methods: Fifty-four patients (108 orbits) with exophthalmos in the course of Graves’ orbitopathy were enrolled in the study. Two measurements on axial T2W orbital MRI images were performed by 2 independent radiologists: the distance from the interzygomatic line to the anterior surface of the globe (AD) and the distance from the interzygomatic line to the posterior sclera (PD). Within 4 weeks, an exophthalmometry was performed by an ophthalmologist using a Hertel exophthalmometer. The inter-observer variation was assessed using the Pearson correlation coefficient. Values were presented as mean and standard deviation, and the differences in values were explored with Student’s t-test. Results: The mean AD measured on MRI by the first observer was 20.6 ± 3 mm, and 20.6 ± 2.9 mm by the second observer. PD values were 2.9 ± 2.8 mm and 3.4 ± 2.8 mm, respectively. The mean exophthalmometry result was 21 ± 3.3 mm. The correlation was very high between observers for AD measurements (r = 0.98, p = 0.01) and high for PD measurements (r = 0.95, p = 0.01). AD measurements on MRI and exophthalmometry results were strongly correlated (r = 0.9, p = 0.01). Conclusions: The AD measurement has better reproducibility and is directly correlated with Hertel exophthalmometry. This method could be sufficient in routine practice.
| cris.lastimport.wos | 2024-04-09T20:59:40Z | |
| dc.abstract.en | Purpose: Although assessment of the orbital structures using magnetic resonance imaging (MRI) is well described in the literature, there is no consensus as to which measurement method is the most useful in exophthalmos assessment. The aim of the study was to correlate 2 MRI methods of exophthalmos measurement with exophthalmometry results and to determine a proper technique of exophthalmos measurement. Material and methods: Fifty-four patients (108 orbits) with exophthalmos in the course of Graves’ orbitopathy were enrolled in the study. Two measurements on axial T2W orbital MRI images were performed by 2 independent radiologists: the distance from the interzygomatic line to the anterior surface of the globe (AD) and the distance from the interzygomatic line to the posterior sclera (PD). Within 4 weeks, an exophthalmometry was performed by an ophthalmologist using a Hertel exophthalmometer. The inter-observer variation was assessed using the Pearson correlation coefficient. Values were presented as mean and standard deviation, and the differences in values were explored with Student’s t-test. Results: The mean AD measured on MRI by the first observer was 20.6 ± 3 mm, and 20.6 ± 2.9 mm by the second observer. PD values were 2.9 ± 2.8 mm and 3.4 ± 2.8 mm, respectively. The mean exophthalmometry result was 21 ± 3.3 mm. The correlation was very high between observers for AD measurements (r = 0.98, p = 0.01) and high for PD measurements (r = 0.95, p = 0.01). AD measurements on MRI and exophthalmometry results were strongly correlated (r = 0.9, p = 0.01). Conclusions: The AD measurement has better reproducibility and is directly correlated with Hertel exophthalmometry. This method could be sufficient in routine practice. | pl |
| dc.contributor.author | Wnuk, Emilia | pl |
| dc.contributor.author | Maj, Edyta | pl |
| dc.contributor.author | Jabłońska-Pawlak, Anna | pl |
| dc.contributor.author | Jeczeń, Maria | pl |
| dc.contributor.author | Rowińska-Berman, Katarzyna | pl |
| dc.contributor.author | Rowiński, Olgierd | pl |
| dc.date.accessioned | 2023-04-12T12:18:10Z | |
| dc.date.available | 2023-04-12T12:18:10Z | |
| dc.date.issued | 2022 | pl |
| dc.date.openaccess | 0 | |
| dc.description.accesstime | w momencie opublikowania | |
| dc.description.additional | Bibliogr. s. e543-e544 | pl |
| dc.description.physical | e539-e544 | pl |
| dc.description.version | ostateczna wersja wydawcy | |
| dc.description.volume | 87 | pl |
| dc.identifier.doi | 10.5114/pjr.2022.119939 | pl |
| dc.identifier.eissn | 1899-0967 | pl |
| dc.identifier.issn | 1733-134X | pl |
| dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/310271 | |
| dc.language | eng | pl |
| dc.language.container | eng | pl |
| dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
| dc.rights.licence | CC-BY-NC-ND | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
| dc.share.type | otwarte czasopismo | |
| dc.subject.en | exophthalmos | pl |
| dc.subject.en | proptosis | pl |
| dc.subject.en | Hertel exophthalmometry | pl |
| dc.subject.en | Graves' orbitopathy | pl |
| dc.subject.en | thyroid-associated orbitopathy | pl |
| dc.subject.en | MRI | pl |
| dc.subtype | Article | pl |
| dc.title | Validation of exophthalmos magnetic resonance imaging measurements in patients with Graves’ orbitopathy, compared to ophthalmometry results | pl |
| dc.title.journal | Polish Journal of Radiology | pl |
| dc.type | JournalArticle | pl |
| dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
2
Views per month
Views per city
Downloads
Open Access