Influence of pH measurement inaccuracy on the values of acidity constant determined on the basis of electrophoretic and thermophoretic data
acid-base equilibrium
acid dissociation constant
capillary electrophoresis
pH measurement
microscale thermophoresis
thermodynamics
Data from pH measurements and all calculations of asses the influence of incorrect pH measurement on the pKa values obtained by capillary electrophoresis (CE) and microscale thermophoresis (MST). It includes models and thermodynamic analysis.
The accuracy of the acid dissociation constant (pKa) determined by experimental techniques depends on the potential errors in the pH measurement. This dependence is obvious, but, according to common practice, this effect is either ignored or treated in a greatly simplified manner when discussing the credibility of obtained pKa values. This paper investigates the influence of incorrect pH measurement on the pKa values obtained by capillary electrophoresis (CE) and microscale thermophoresis (MST). A simple self-control procedure has been proposed to control and reliably predict the corresponding total uncertainty of the acidity constant. The significance of the pH measurement error was also investigated in relation to the thermodynamic analysis, which requires determining the thermal dependency of pKa values. The obtained results clearly indicate that the investigated effect should not be ignored, and the actual accuracy of methods using electrophoretic separation may be worse than commonly assumed. It also points at the need to develop alternative methods that do not require measuring pH, such as a known internal standard-based approach. Besides pH-related effects, other sources of inaccuracy of pKa constant should also be considered.
cris.lastimport.wos | 2024-04-09T23:50:53Z | |
dc.abstract.en | The accuracy of the acid dissociation constant (pKa) determined by experimental techniques depends on the potential errors in the pH measurement. This dependence is obvious, but, according to common practice, this effect is either ignored or treated in a greatly simplified manner when discussing the credibility of obtained pKa values. This paper investigates the influence of incorrect pH measurement on the pKa values obtained by capillary electrophoresis (CE) and microscale thermophoresis (MST). A simple self-control procedure has been proposed to control and reliably predict the corresponding total uncertainty of the acidity constant. The significance of the pH measurement error was also investigated in relation to the thermodynamic analysis, which requires determining the thermal dependency of pKa values. The obtained results clearly indicate that the investigated effect should not be ignored, and the actual accuracy of methods using electrophoretic separation may be worse than commonly assumed. It also points at the need to develop alternative methods that do not require measuring pH, such as a known internal standard-based approach. Besides pH-related effects, other sources of inaccuracy of pKa constant should also be considered. | pl |
dc.affiliation | Wydział Chemii : Zakład Chemii Analitycznej | pl |
dc.affiliation | Szkoła Doktorska Nauk Ścisłych i Przyrodniczych | pl |
dc.contributor.author | Nowak, Paweł - 149463 | pl |
dc.contributor.author | Biel, Iwona - 361094 | pl |
dc.contributor.author | Kózka, Gabriela | pl |
dc.contributor.author | Klag, Maria | pl |
dc.contributor.author | Woźniakiewicz, Michał - 142043 | pl |
dc.contributor.institution | Zakład Chemii Analitycznej, Wydział Chemii, Uniwersytet Jagielloński | pl |
dc.coverage.temporal | 2021-11-02 – 2022-06-02 | pl |
dc.date.accessioned | 2022-06-03T07:09:45Z | |
dc.date.available | 2022-06-03T07:09:45Z | |
dc.date.issued | 2022 | pl |
dc.description.additional | Data from pH measurements and all calculations of asses the influence of incorrect pH measurement on the pKa values obtained by capillary electrophoresis (CE) and microscale thermophoresis (MST). It includes models and thermodynamic analysis. | pl |
dc.description.grantnumber | 2019/35/B/ST4/01022 | pl |
dc.description.granttitle | Kompleksowa ocena analitycznego potencjału elektroforezy kapilarnej sprzężonej z mikroskalową termoforezą (CE-MST) | pl |
dc.description.sponsorship | Narodowe Centrum Nauki | pl |
dc.description.version | 1 | pl |
dc.identifier.doi | 10.26106/cc71-jj37 | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/292612 | |
dc.language | eng | pl |
dc.pbn.affiliation | Dziedzina nauk ścisłych i przyrodniczych : nauki chemiczne | pl |
dc.pubinfo | Kraków : Repozytorium Uniwersytetu Jagiellońskiego | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/legalcode.pl | * |
dc.subject.en | acid-base equilibrium | pl |
dc.subject.en | acid dissociation constant | pl |
dc.subject.en | capillary electrophoresis | pl |
dc.subject.en | pH measurement | pl |
dc.subject.en | microscale thermophoresis | pl |
dc.subject.en | thermodynamics | pl |
dc.subtype | Collection | pl |
dc.title | Influence of pH measurement inaccuracy on the values of acidity constant determined on the basis of electrophoretic and thermophoretic data | pl |
dc.type | ResearchData | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.