Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) of the major salivary glands : an assessment of the optimal number and combination of b-values

2022
journal article
article
1
dc.abstract.enPurpose: To examine the optimal number and combination of b-values in intravoxel incoherent motion (IVIM) diffusionweighted imaging (DWI) of the major salivary glands. Material and methods: IVIM-DWI was performed on 10 healthy volunteers using 13 b-values (low b-values: 0-100 s/mm2; high b-values: 200-1000 s/mm2). The IVIM parameters and apparent diffusion coefficient of the bilateral major salivary glands were calculated using 13 b-values and were considered the standard values. We sequentially reduced the number of b-values to 10, 8, 6, and 5. The parameters in each combination were calculated. The standard values were compared with the parameters from each reduced b-value in IVIM-DWI. The Wilcoxon signed-rank test was used to determine whether there were any differences between the parameters in each combination. Bonferroni correction was conducted for multiple comparisons. Results: There were no significant differences between the standard values and parameters from the 2 combinations of 6 b-values. However, significant differences were observed between the standard values and parameters from some combinations of only 2 low or only 2 high b-values. Conclusions: IVIM-DWI of the major salivary glands could be performed using a minimum of 6 b-values. However, they should contain 3 low and 3 high b-values.pl
dc.contributor.authorKimura, Mitsuhiropl
dc.contributor.authorYabuuchi, Hidetakepl
dc.contributor.authorNarita, Hiroshipl
dc.contributor.authorHisada, Kiyoshipl
dc.contributor.authorSakai, Noriyukipl
dc.contributor.authorNagatomo, Kazuyapl
dc.contributor.authorMikayama, Ryojipl
dc.contributor.authorMasaki, Masafumipl
dc.contributor.authorKimura, Hiroshipl
dc.date.accessioned2022-05-23T08:22:03Z
dc.date.available2022-05-23T08:22:03Z
dc.date.issued2022pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e255-e256pl
dc.description.physicale246-e256pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume87pl
dc.identifier.doi10.5114/pjr.2022.116167pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/292184
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.ensalivary glandspl
dc.subject.enmagnetic resonance imagingpl
dc.subject.endiffusionpl
dc.subject.enperfusionpl
dc.subject.enquantitative evaluationpl
dc.subtypeArticlepl
dc.titleIntravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) of the major salivary glands : an assessment of the optimal number and combination of b-valuespl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Purpose: To examine the optimal number and combination of b-values in intravoxel incoherent motion (IVIM) diffusionweighted imaging (DWI) of the major salivary glands. Material and methods: IVIM-DWI was performed on 10 healthy volunteers using 13 b-values (low b-values: 0-100 s/mm2; high b-values: 200-1000 s/mm2). The IVIM parameters and apparent diffusion coefficient of the bilateral major salivary glands were calculated using 13 b-values and were considered the standard values. We sequentially reduced the number of b-values to 10, 8, 6, and 5. The parameters in each combination were calculated. The standard values were compared with the parameters from each reduced b-value in IVIM-DWI. The Wilcoxon signed-rank test was used to determine whether there were any differences between the parameters in each combination. Bonferroni correction was conducted for multiple comparisons. Results: There were no significant differences between the standard values and parameters from the 2 combinations of 6 b-values. However, significant differences were observed between the standard values and parameters from some combinations of only 2 low or only 2 high b-values. Conclusions: IVIM-DWI of the major salivary glands could be performed using a minimum of 6 b-values. However, they should contain 3 low and 3 high b-values.
dc.contributor.authorpl
Kimura, Mitsuhiro
dc.contributor.authorpl
Yabuuchi, Hidetake
dc.contributor.authorpl
Narita, Hiroshi
dc.contributor.authorpl
Hisada, Kiyoshi
dc.contributor.authorpl
Sakai, Noriyuki
dc.contributor.authorpl
Nagatomo, Kazuya
dc.contributor.authorpl
Mikayama, Ryoji
dc.contributor.authorpl
Masaki, Masafumi
dc.contributor.authorpl
Kimura, Hiroshi
dc.date.accessioned
2022-05-23T08:22:03Z
dc.date.available
2022-05-23T08:22:03Z
dc.date.issuedpl
2022
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e255-e256
dc.description.physicalpl
e246-e256
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
87
dc.identifier.doipl
10.5114/pjr.2022.116167
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/292184
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
salivary glands
dc.subject.enpl
magnetic resonance imaging
dc.subject.enpl
diffusion
dc.subject.enpl
perfusion
dc.subject.enpl
quantitative evaluation
dc.subtypepl
Article
dc.titlepl
Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) of the major salivary glands : an assessment of the optimal number and combination of b-values
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
17
Views per month
Views per city
Ashburn
3
Dublin
3
New York
2
Wroclaw
2
Krakow
1
San Jose
1
Downloads
kimura_yabuuchi_narita_kurihara_hisada_sakai_nagatomo_mikayama_masaki_kimura_intravoxel_incoherent_motion_diffusion-weighted_imaging_2022.odt
18
kimura_yabuuchi_narita_kurihara_hisada_sakai_nagatomo_mikayama_masaki_kimura_intravoxel_incoherent_motion_diffusion-weighted_imaging_2022.pdf
13