Simple view
Full metadata view
Authors
Statistics
Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) of the major salivary glands : an assessment of the optimal number and combination of b-values
salivary glands
magnetic resonance imaging
diffusion
perfusion
quantitative evaluation
Bibliogr. s. e255-e256
Purpose: To examine the optimal number and combination of b-values in intravoxel incoherent motion (IVIM) diffusionweighted imaging (DWI) of the major salivary glands. Material and methods: IVIM-DWI was performed on 10 healthy volunteers using 13 b-values (low b-values: 0-100 s/mm2; high b-values: 200-1000 s/mm2). The IVIM parameters and apparent diffusion coefficient of the bilateral major salivary glands were calculated using 13 b-values and were considered the standard values. We sequentially reduced the number of b-values to 10, 8, 6, and 5. The parameters in each combination were calculated. The standard values were compared with the parameters from each reduced b-value in IVIM-DWI. The Wilcoxon signed-rank test was used to determine whether there were any differences between the parameters in each combination. Bonferroni correction was conducted for multiple comparisons. Results: There were no significant differences between the standard values and parameters from the 2 combinations of 6 b-values. However, significant differences were observed between the standard values and parameters from some combinations of only 2 low or only 2 high b-values. Conclusions: IVIM-DWI of the major salivary glands could be performed using a minimum of 6 b-values. However, they should contain 3 low and 3 high b-values.
dc.abstract.en | Purpose: To examine the optimal number and combination of b-values in intravoxel incoherent motion (IVIM) diffusionweighted imaging (DWI) of the major salivary glands. Material and methods: IVIM-DWI was performed on 10 healthy volunteers using 13 b-values (low b-values: 0-100 s/mm2; high b-values: 200-1000 s/mm2). The IVIM parameters and apparent diffusion coefficient of the bilateral major salivary glands were calculated using 13 b-values and were considered the standard values. We sequentially reduced the number of b-values to 10, 8, 6, and 5. The parameters in each combination were calculated. The standard values were compared with the parameters from each reduced b-value in IVIM-DWI. The Wilcoxon signed-rank test was used to determine whether there were any differences between the parameters in each combination. Bonferroni correction was conducted for multiple comparisons. Results: There were no significant differences between the standard values and parameters from the 2 combinations of 6 b-values. However, significant differences were observed between the standard values and parameters from some combinations of only 2 low or only 2 high b-values. Conclusions: IVIM-DWI of the major salivary glands could be performed using a minimum of 6 b-values. However, they should contain 3 low and 3 high b-values. | pl |
dc.contributor.author | Kimura, Mitsuhiro | pl |
dc.contributor.author | Yabuuchi, Hidetake | pl |
dc.contributor.author | Narita, Hiroshi | pl |
dc.contributor.author | Hisada, Kiyoshi | pl |
dc.contributor.author | Sakai, Noriyuki | pl |
dc.contributor.author | Nagatomo, Kazuya | pl |
dc.contributor.author | Mikayama, Ryoji | pl |
dc.contributor.author | Masaki, Masafumi | pl |
dc.contributor.author | Kimura, Hiroshi | pl |
dc.date.accessioned | 2022-05-23T08:22:03Z | |
dc.date.available | 2022-05-23T08:22:03Z | |
dc.date.issued | 2022 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. e255-e256 | pl |
dc.description.physical | e246-e256 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 87 | pl |
dc.identifier.doi | 10.5114/pjr.2022.116167 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/292184 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | salivary glands | pl |
dc.subject.en | magnetic resonance imaging | pl |
dc.subject.en | diffusion | pl |
dc.subject.en | perfusion | pl |
dc.subject.en | quantitative evaluation | pl |
dc.subtype | Article | pl |
dc.title | Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) of the major salivary glands : an assessment of the optimal number and combination of b-values | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
17
Views per month
Views per city
Downloads
Open Access