Diffusion-weighted magnetic resonance imaging at 1.5 T for peripheral zone prostate cancer : the influence of the b-value combination on the diagnostic performance of apparent diffusion coefficient

2022
journal article
article
3
cris.lastimport.wos2024-04-10T02:38:40Z
dc.abstract.enPurpose: Diffusion-weighted imaging as a noninvasive functional modality plays a valuable role in the evaluation of prostate cancer. However, there is still no agreement on the number and range of b-values to be used. Therefore, the purpose of this study is to investigate the influence of b-value choice on the diagnostic performance of apparent diffusion coefficient (ADC) values for prostate cancer detection. Material and methods: Fifty-nine consecutive patients with abnormal digital rectal examination findings and raised serum prostate-specific antigen were chosen for magnetic resonance imaging of the prostate before systematic 12-core transrectal ultrasound-guided prostate biopsies. ADC values for each ROI were calculated from different b-value combinations (0-1600 s/mm2) by a monoexponential model. Mann-Whitney and the paired-sample t-test were used to compare the mean ADC values for malignant lesions and noncancerous tissues. ROC curve analysis was used to evaluate the diagnostic performance of ADC values in distinguishing prostate cancer from normal-tissue ROIs. Results: The differences between mean ADC values of malignant lesions and contralateral healthy tissues were significant for all the pairs of b-value combinations. The pair of b-values 50 and 1200 provided the highest AUC (0.94), with a sensitivity of 90.2%, a specificity of 92.6%, and an accuracy of 91.2% at an ADC cut-off of 1.23 × 10-3 mm2/s. Conclusions: Our study showed that using a 1.5-Tesla MRI scanner the diagnostic performance of ADC values estimated from the b-value pair 50 and 1200 s/mm2 was highest. However, some other b-value pairs provided statically comparable diagnostic performance.pl
dc.contributor.authorRezaeian, Abbaspl
dc.contributor.authorOstovari, Mohsenpl
dc.contributor.authorHoseini-Ghahfarokhi, Mojtabapl
dc.contributor.authorKhanbabaei, Hashempl
dc.date.accessioned2022-05-23T08:15:16Z
dc.date.available2022-05-23T08:15:16Z
dc.date.issued2022pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e219pl
dc.description.physicale215-e219pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume87pl
dc.identifier.doi10.5114/pjr.2022.115715pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/292182
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enprostate cancerpl
dc.subject.enADCpl
dc.subject.endetectionpl
dc.subject.enb-valuepl
dc.subject.endiffusion weightedpl
dc.subtypeArticlepl
dc.titleDiffusion-weighted magnetic resonance imaging at 1.5 T for peripheral zone prostate cancer : the influence of the b-value combination on the diagnostic performance of apparent diffusion coefficientpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T02:38:40Z
dc.abstract.enpl
Purpose: Diffusion-weighted imaging as a noninvasive functional modality plays a valuable role in the evaluation of prostate cancer. However, there is still no agreement on the number and range of b-values to be used. Therefore, the purpose of this study is to investigate the influence of b-value choice on the diagnostic performance of apparent diffusion coefficient (ADC) values for prostate cancer detection. Material and methods: Fifty-nine consecutive patients with abnormal digital rectal examination findings and raised serum prostate-specific antigen were chosen for magnetic resonance imaging of the prostate before systematic 12-core transrectal ultrasound-guided prostate biopsies. ADC values for each ROI were calculated from different b-value combinations (0-1600 s/mm2) by a monoexponential model. Mann-Whitney and the paired-sample t-test were used to compare the mean ADC values for malignant lesions and noncancerous tissues. ROC curve analysis was used to evaluate the diagnostic performance of ADC values in distinguishing prostate cancer from normal-tissue ROIs. Results: The differences between mean ADC values of malignant lesions and contralateral healthy tissues were significant for all the pairs of b-value combinations. The pair of b-values 50 and 1200 provided the highest AUC (0.94), with a sensitivity of 90.2%, a specificity of 92.6%, and an accuracy of 91.2% at an ADC cut-off of 1.23 × 10-3 mm2/s. Conclusions: Our study showed that using a 1.5-Tesla MRI scanner the diagnostic performance of ADC values estimated from the b-value pair 50 and 1200 s/mm2 was highest. However, some other b-value pairs provided statically comparable diagnostic performance.
dc.contributor.authorpl
Rezaeian, Abbas
dc.contributor.authorpl
Ostovari, Mohsen
dc.contributor.authorpl
Hoseini-Ghahfarokhi, Mojtaba
dc.contributor.authorpl
Khanbabaei, Hashem
dc.date.accessioned
2022-05-23T08:15:16Z
dc.date.available
2022-05-23T08:15:16Z
dc.date.issuedpl
2022
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e219
dc.description.physicalpl
e215-e219
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
87
dc.identifier.doipl
10.5114/pjr.2022.115715
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/292182
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
prostate cancer
dc.subject.enpl
ADC
dc.subject.enpl
detection
dc.subject.enpl
b-value
dc.subject.enpl
diffusion weighted
dc.subtypepl
Article
dc.titlepl
Diffusion-weighted magnetic resonance imaging at 1.5 T for peripheral zone prostate cancer : the influence of the b-value combination on the diagnostic performance of apparent diffusion coefficient
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
19
Views per month
Views per city
Ashburn
4
Dublin
3
Wroclaw
2
Krakow
1
Lappeenranta
1
San Jose
1
Szczecin
1
Downloads
rezaeian_ostovari_hoseini-ghahfarokhi_khanbabaei_diffusion-weighted_magnetic_resonance_imaging_2022.pdf
10
rezaeian_ostovari_hoseini-ghahfarokhi_khanbabaei_diffusion-weighted_magnetic_resonance_imaging_2022.odt
6