Volumetric measurements of target lesions : does it improve inter-reader variability for oncological response assessment according to RECIST 1.1 guidelines compared to standard unidimensional measurements?

2021
journal article
article
6
cris.lastimport.wos2024-04-10T00:16:48Z
dc.abstract.enPurpose: Target lesion selection is known to be a major factor for inter-reader discordance in RECIST 1.1. The purpose of this study was to assess whether volumetric measurements of target lesions result in different response categorization, as opposed to standard unidimensional measurements, and to evaluate the impact on inter-reader agreement for response categorization when different readers select different sets of target lesions. Material and methods: Fifty patients with measurable disease from solid tumours, in which 3 readers had blindly and independently selected different sets of target lesions and subsequently reached clinically significant discordant response categorizations (progressive disease [PD] vs. non-progressive disease [non-PD]) based on RECIST 1.1 analyses were included in this study. Additional volumetric measurements of all target lesions were performed by the same readers in a second read. Intra-reader agreement between standard unidimensional measurements (uRECIST) and volumetric measurements (vRECIST) was assessed using Cohen's k statistics. Fleiss k statistics was used to analyse the inter-reader agreement for uRECIST and vRECIST results. Results: The 3 readers assigned the same response classifications based on uRECIST and vRECIST in 33/50 (66%), 42/50 patients (84%), and 44/50 patients (88%), respectively. Inter-reader agreement improved from 0% when using uRECIST to 36% when using vRECIST. Conclusions: Volumetric measurement of target lesions may improve inter-reader variability for response assessment as opposed to standard unidimensional measurements. However, in about two-thirds of patients, readers disagreed regardless of the measurement method, indicating that a limited set of target lesions may not be sufficiently representative of the whole-body tumour burden.pl
dc.contributor.authorZimmermann, Markuspl
dc.contributor.authorKuhl, Christianepl
dc.contributor.authorEngelke, Hannapl
dc.contributor.authorBettermann, Gerhardpl
dc.contributor.authorKeil, Sebastianpl
dc.date.accessioned2022-03-11T06:47:29Z
dc.date.available2022-03-11T06:47:29Z
dc.date.issued2021pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e600pl
dc.description.physicale594-e600pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume86pl
dc.identifier.doi10.5114/pjr.2021.111048pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/288962
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enRECIST 1.1pl
dc.subject.eninter-reader variabilitypl
dc.subject.entarget lesionpl
dc.subject.envolumetric measurementpl
dc.subtypeArticlepl
dc.titleVolumetric measurements of target lesions : does it improve inter-reader variability for oncological response assessment according to RECIST 1.1 guidelines compared to standard unidimensional measurements?pl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T00:16:48Z
dc.abstract.enpl
Purpose: Target lesion selection is known to be a major factor for inter-reader discordance in RECIST 1.1. The purpose of this study was to assess whether volumetric measurements of target lesions result in different response categorization, as opposed to standard unidimensional measurements, and to evaluate the impact on inter-reader agreement for response categorization when different readers select different sets of target lesions. Material and methods: Fifty patients with measurable disease from solid tumours, in which 3 readers had blindly and independently selected different sets of target lesions and subsequently reached clinically significant discordant response categorizations (progressive disease [PD] vs. non-progressive disease [non-PD]) based on RECIST 1.1 analyses were included in this study. Additional volumetric measurements of all target lesions were performed by the same readers in a second read. Intra-reader agreement between standard unidimensional measurements (uRECIST) and volumetric measurements (vRECIST) was assessed using Cohen's k statistics. Fleiss k statistics was used to analyse the inter-reader agreement for uRECIST and vRECIST results. Results: The 3 readers assigned the same response classifications based on uRECIST and vRECIST in 33/50 (66%), 42/50 patients (84%), and 44/50 patients (88%), respectively. Inter-reader agreement improved from 0% when using uRECIST to 36% when using vRECIST. Conclusions: Volumetric measurement of target lesions may improve inter-reader variability for response assessment as opposed to standard unidimensional measurements. However, in about two-thirds of patients, readers disagreed regardless of the measurement method, indicating that a limited set of target lesions may not be sufficiently representative of the whole-body tumour burden.
dc.contributor.authorpl
Zimmermann, Markus
dc.contributor.authorpl
Kuhl, Christiane
dc.contributor.authorpl
Engelke, Hanna
dc.contributor.authorpl
Bettermann, Gerhard
dc.contributor.authorpl
Keil, Sebastian
dc.date.accessioned
2022-03-11T06:47:29Z
dc.date.available
2022-03-11T06:47:29Z
dc.date.issuedpl
2021
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e600
dc.description.physicalpl
e594-e600
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
86
dc.identifier.doipl
10.5114/pjr.2021.111048
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/288962
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
RECIST 1.1
dc.subject.enpl
inter-reader variability
dc.subject.enpl
target lesion
dc.subject.enpl
volumetric measurement
dc.subtypepl
Article
dc.titlepl
Volumetric measurements of target lesions : does it improve inter-reader variability for oncological response assessment according to RECIST 1.1 guidelines compared to standard unidimensional measurements?
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
15
Views per month
Views per city
Dublin
3
Ashburn
2
Poznan
2
Wroclaw
2
Bayreuth
1
Brussels
1
Krakow
1
Downloads
zimmermann_kuhl_engelke_bettermann_keil_volumetric_measurements_of_target_lesions_2021.pdf
15
zimmermann_kuhl_engelke_bettermann_keil_volumetric_measurements_of_target_lesions_2021.odt
4