Elektrochemiczne oznaczenie metali ciężkich z wykorzystaniem detektora bezpośredniego wstrzyku

master
dc.abstract.enIn this work, a system for voltammetric determination of cadmium and lead ions using a Direct Injection Detector (DID) was developed as well a new analytical procedure. Measuring system was a combination of the electrochemical technique - Differential Pulse Anodic Stripping Voltammetry (DPASV) and the flow system. In the beginning of the optimization process, the most favorable values of electrochemical parameters were checked. In further stages of this work, the experimental parameters related to the flow system were optimized, as well the electrodes conditioning process performed in stationary way and in the flow system. The study showed that the interference effect of copper ions was the biggest, especially during the recording of the analytical signal for cadmium ions. The optimized analytical method was linear in the range of: 20 - 2000 nmol/L. The sensitivity of determination of cadmium and lead ions was achieved at the level of 111.24 µA·L/µmol and 29.57 µA·L/µmol, respectively. The optimization allowed to achieve low values of limits of detection and limits of quantification of the analyzed ions equal 43.0 and 143.4 nmol/L for cadmium ions and 9.75 and 32.5 nmol/L for lead ions, respectively. The optimized analytical procedure was also tested on natural samples such as tap water and white wine. Due to the interference effect of the components of tap water and wine, the correct concentrations of the analyzed ions were not obtained.pl
dc.abstract.plW niniejszej pracy opracowano układ przeznaczony do woltamperometrycznego oznaczania jonów kadmu i ołowiu wykorzystujący detektor bezpośredniego wstrzyku, jak również opracowano oraz zoptymalizowano nową procedurę analityczną. Układ badawczy był połączeniem techniki elektrochemicznej - anodowej impulsowej różnicowej woltamperometrii inwersyjnej (DPASV) i układu przepływowego. W początkowych etapach optymalizacyjnych ustalono najbardziej korzystne wartości parametrów elektrochemicznych, wynikających bezpośrednio ze stosowanej techniki woltamperometrycznej. W dalszych etapach pracy zoptymalizowano warunki prowadzenia procesu związane z układem przepływowym oraz stacjonarnym i wykonywanym w układzie przepływowym procesie kondycjonowania elektrody. W ramach prowadzonych badaniach, przeprowadzano również doświadczenia wykazujące wpływ potencjalnych interferentów na jednoczesne oznaczanie jonów kadmu i ołowiu. W pracy wykazano, iż interferencyjny wpływ jonów miedzi był największy, zwłaszcza podczas rejestracji sygnału analitycznego dla jonów kadmu. Zoptymalizowana metoda analityczna charakteryzowała się liniowością w zakresie: 20 - 2000 nmol/L, czułością dla kadmu i ołowiu wynoszącą odpowiednio 29,57 i 111,24 μA·L/μmol. Zastosowanie zoptymalizowanej procedury analitycznej pozwoliło również osiągnąć niskie granice wykrywalności i oznaczalności rzędu 43,02 i 143,39 nmol/L odpowiednio dla jonów kadmu oraz 9,75 i 32,5 nmol/L dla jonów ołowiu. Zoptymalizowaną procedurę analityczną wypróbowano, także podczas analizy próbek naturalnych, którymi były woda wodociągowa oraz wino białe. Z uwagi na interferencyjny wpływ składników wody wodociągowej i wina nie uzyskano prawidłowych stężeń analizowanych jonów.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorKnihnicki, Pawełpl
dc.contributor.authorKusior, Bartłomiejpl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerKnihnicki, Pawełpl
dc.contributor.reviewerKochana, Jolanta - 128954 pl
dc.date.accessioned2021-06-23T21:33:04Z
dc.date.available2021-06-23T21:33:04Z
dc.date.submitted2021-06-23pl
dc.fieldofstudychemiapl
dc.identifier.apddiploma-146399-279388pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/274714
dc.languagepolpl
dc.subject.encadmium, lead, direct injection detector, flow system, halloysitepl
dc.subject.plkadm, ołów, detektor bezpośredniego wstrzyku, układ przepływowy, haloizytpl
dc.titleElektrochemiczne oznaczenie metali ciężkich z wykorzystaniem detektora bezpośredniego wstrzykupl
dc.title.alternativeElectrochemical determination of heavy metals using a Direct Injection Detectorpl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
In this work, a system for voltammetric determination of cadmium and lead ions using a Direct Injection Detector (DID) was developed as well a new analytical procedure. Measuring system was a combination of the electrochemical technique - Differential Pulse Anodic Stripping Voltammetry (DPASV) and the flow system. In the beginning of the optimization process, the most favorable values of electrochemical parameters were checked. In further stages of this work, the experimental parameters related to the flow system were optimized, as well the electrodes conditioning process performed in stationary way and in the flow system. The study showed that the interference effect of copper ions was the biggest, especially during the recording of the analytical signal for cadmium ions. The optimized analytical method was linear in the range of: 20 - 2000 nmol/L. The sensitivity of determination of cadmium and lead ions was achieved at the level of 111.24 µA·L/µmol and 29.57 µA·L/µmol, respectively. The optimization allowed to achieve low values of limits of detection and limits of quantification of the analyzed ions equal 43.0 and 143.4 nmol/L for cadmium ions and 9.75 and 32.5 nmol/L for lead ions, respectively. The optimized analytical procedure was also tested on natural samples such as tap water and white wine. Due to the interference effect of the components of tap water and wine, the correct concentrations of the analyzed ions were not obtained.
dc.abstract.plpl
W niniejszej pracy opracowano układ przeznaczony do woltamperometrycznego oznaczania jonów kadmu i ołowiu wykorzystujący detektor bezpośredniego wstrzyku, jak również opracowano oraz zoptymalizowano nową procedurę analityczną. Układ badawczy był połączeniem techniki elektrochemicznej - anodowej impulsowej różnicowej woltamperometrii inwersyjnej (DPASV) i układu przepływowego. W początkowych etapach optymalizacyjnych ustalono najbardziej korzystne wartości parametrów elektrochemicznych, wynikających bezpośrednio ze stosowanej techniki woltamperometrycznej. W dalszych etapach pracy zoptymalizowano warunki prowadzenia procesu związane z układem przepływowym oraz stacjonarnym i wykonywanym w układzie przepływowym procesie kondycjonowania elektrody. W ramach prowadzonych badaniach, przeprowadzano również doświadczenia wykazujące wpływ potencjalnych interferentów na jednoczesne oznaczanie jonów kadmu i ołowiu. W pracy wykazano, iż interferencyjny wpływ jonów miedzi był największy, zwłaszcza podczas rejestracji sygnału analitycznego dla jonów kadmu. Zoptymalizowana metoda analityczna charakteryzowała się liniowością w zakresie: 20 - 2000 nmol/L, czułością dla kadmu i ołowiu wynoszącą odpowiednio 29,57 i 111,24 μA·L/μmol. Zastosowanie zoptymalizowanej procedury analitycznej pozwoliło również osiągnąć niskie granice wykrywalności i oznaczalności rzędu 43,02 i 143,39 nmol/L odpowiednio dla jonów kadmu oraz 9,75 i 32,5 nmol/L dla jonów ołowiu. Zoptymalizowaną procedurę analityczną wypróbowano, także podczas analizy próbek naturalnych, którymi były woda wodociągowa oraz wino białe. Z uwagi na interferencyjny wpływ składników wody wodociągowej i wina nie uzyskano prawidłowych stężeń analizowanych jonów.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Knihnicki, Paweł
dc.contributor.authorpl
Kusior, Bartłomiej
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Knihnicki, Paweł
dc.contributor.reviewerpl
Kochana, Jolanta - 128954
dc.date.accessioned
2021-06-23T21:33:04Z
dc.date.available
2021-06-23T21:33:04Z
dc.date.submittedpl
2021-06-23
dc.fieldofstudypl
chemia
dc.identifier.apdpl
diploma-146399-279388
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/274714
dc.languagepl
pol
dc.subject.enpl
cadmium, lead, direct injection detector, flow system, halloysite
dc.subject.plpl
kadm, ołów, detektor bezpośredniego wstrzyku, układ przepływowy, haloizyt
dc.titlepl
Elektrochemiczne oznaczenie metali ciężkich z wykorzystaniem detektora bezpośredniego wstrzyku
dc.title.alternativepl
Electrochemical determination of heavy metals using a Direct Injection Detector
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
29
Views per month
Views per city
Krakow
8
Warsaw
6
Wroclaw
3
Dąbrowa Tarnowska
2
Gdansk
2
Niepolomice
2
Bydgoszcz
1
Dublin
1
Shanghai
1
Zabrze
1

No access

No Thumbnail Available