Simple view
Full metadata view
Authors
Statistics
The utility of ADC parameters in the diagnosis of clinically significant prostate cancer by 3.0-Tesla diffusion-weighted magnetic resonance imaging
prostate cancer
Gleason score
diffusion-weighted imaging
multiparametric prostate MR
apparent diffusion coefficient
Bibliogr. s. e267-e268
Purpose: This study has focused on investigating the relationship between the exponential apparent diffusion coefficient (exp-ADC), selective apparent diffusion coefficient (sel-ADC) values, the ADC ratio (ADCr), and prostate cancer aggressiveness with transrectal ultrasound-guided prostate biopsy in patients with prostate cancer. Material and methods: All patients underwent a multiparametric magnetic resonance imaging (mpMRI) including tri-planar T2-weighted (T2W), dynamic contrast-enhanced (DCE), diffusion-weighted sequences using a 3.0-Tesla MR scanner (Skyra, Siemens Medical Systems, Germany) with a dedicated 18-channel body coil and a spine coil underneath the pelvis, with the patient in the supine position. Exp-ADC, sel-ADC, and ADCr of defined lesions were evaluated using region-of-interest-based measurements. Exp-ADC, sel-ADC, and ADCr were correlated with the Gleason score obtained through transrectal ultrasound-guided biopsy. Results: Patients were divided into 2 groups. Group I is Gleason score ≥ 3 + 4, group II is Gleason score = 6. Sel-ADC and exp-ADC were statistically significant between 2 groups (0.014 and 0.012, respectively). However, the ADCr difference between nonclinical significant prostate cancer from clinically significant prostate cancer was not significant (p = 0.09). Conclusions: This study is the first to evaluate exp-ADC and sel-ADC values of prostate carcinoma with ADCr. One limitation of this study might be the limited number of patients. Exp-ADC and sel-ADC values in prostate MRI imaging improved the specificity, accuracy, and area under the curve (AUC) for detecting clinically relevant prostate carcinoma. Adding exp-ADC and sel-ADC values to ADCr can be used to increase the diagnostic accuracy of DWI.
dc.abstract.en | Purpose: This study has focused on investigating the relationship between the exponential apparent diffusion coefficient (exp-ADC), selective apparent diffusion coefficient (sel-ADC) values, the ADC ratio (ADCr), and prostate cancer aggressiveness with transrectal ultrasound-guided prostate biopsy in patients with prostate cancer. Material and methods: All patients underwent a multiparametric magnetic resonance imaging (mpMRI) including tri-planar T2-weighted (T2W), dynamic contrast-enhanced (DCE), diffusion-weighted sequences using a 3.0-Tesla MR scanner (Skyra, Siemens Medical Systems, Germany) with a dedicated 18-channel body coil and a spine coil underneath the pelvis, with the patient in the supine position. Exp-ADC, sel-ADC, and ADCr of defined lesions were evaluated using region-of-interest-based measurements. Exp-ADC, sel-ADC, and ADCr were correlated with the Gleason score obtained through transrectal ultrasound-guided biopsy. Results: Patients were divided into 2 groups. Group I is Gleason score ≥ 3 + 4, group II is Gleason score = 6. Sel-ADC and exp-ADC were statistically significant between 2 groups (0.014 and 0.012, respectively). However, the ADCr difference between nonclinical significant prostate cancer from clinically significant prostate cancer was not significant (p = 0.09). Conclusions: This study is the first to evaluate exp-ADC and sel-ADC values of prostate carcinoma with ADCr. One limitation of this study might be the limited number of patients. Exp-ADC and sel-ADC values in prostate MRI imaging improved the specificity, accuracy, and area under the curve (AUC) for detecting clinically relevant prostate carcinoma. Adding exp-ADC and sel-ADC values to ADCr can be used to increase the diagnostic accuracy of DWI. | pl |
dc.contributor.author | Altan Kus, Aylin | pl |
dc.date.accessioned | 2021-05-31T14:14:04Z | |
dc.date.available | 2021-05-31T14:14:04Z | |
dc.date.issued | 2021 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. e267-e268 | pl |
dc.description.physical | e262-e268 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 86 | pl |
dc.identifier.doi | 10.5114/pjr.2021.106071 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/271986 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | prostate cancer | pl |
dc.subject.en | Gleason score | pl |
dc.subject.en | diffusion-weighted imaging | pl |
dc.subject.en | multiparametric prostate MR | pl |
dc.subject.en | apparent diffusion coefficient | pl |
dc.subtype | Article | pl |
dc.title | The utility of ADC parameters in the diagnosis of clinically significant prostate cancer by 3.0-Tesla diffusion-weighted magnetic resonance imaging | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |