Elastography: a surrogate marker of renal allograft fibrosis : quantification by shear-wave technique

2021
journal article
article
11
dc.abstract.enPurpose: Renal fibrosis is the most common cause of allograft failure in kidney transplantations. Evaluation of renal abnormalities has progressed considerably over the past years. Currently, the diagnosis of intrarenal fibrosis and quantification of its development with non-invasive assessment tools is possible. This may help in early detection of renal allograft dysfunction. This study sought to assess the efficacy of 2D real-time shear-wave elastography (SWE) in the quantitative measurement of renal allograft dysfunction. Methods: A total of 172 patients were included in our study. SWE was performed in all these patients just before renal allograft biopsy. The cortical elasticity was assessed and described in terms of Young's modulus (kPa). Banff histopathological grading obtained from transplant kidney tissue biopsy was taken as the reference standard. The potential correlation between SWE scores and Banff classification was performed. Results: There was a significant correlation between the Banff grade and mean SWE score, with a correlation coefficient of 0.665 (p < 0.001). The individual correlation coefficients of interstitial fibrosis and tubular atrophy with mean SWE score stood at 0.667 and 0.649 respectively (p < 0.001). The correlation of resistive indices was insignificant when compared to mean polar SWE score in respective poles and the Banff grading of fibrosis. Conclusions: Renal stiffness quantified by 2D SWE showed significant correlation with histopathological renal fibrosis. Thus, the study suggests that shear-wave elastography could be used as a surrogate marker for early detection of renal fibrosis.pl
dc.contributor.authorChhajer, Gulabpl
dc.contributor.authorKasi Arunachalam, Venkateshpl
dc.contributor.authorRamasamy, Rajkumarpl
dc.contributor.authorMehta, Pankajpl
dc.contributor.authorCherian, Mathewpl
dc.date.accessioned2021-03-29T13:01:08Z
dc.date.available2021-03-29T13:01:08Z
dc.date.issued2021pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e156pl
dc.description.physicale151-e156pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume86pl
dc.identifier.doi10.5114/pjr.2021.104582pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/268241
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enelastographypl
dc.subject.enSWEpl
dc.subject.enrenal transplantpl
dc.subject.entransplant fibrosispl
dc.subject.enrenal fibrosispl
dc.subtypeArticlepl
dc.titleElastography: a surrogate marker of renal allograft fibrosis : quantification by shear-wave techniquepl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Purpose: Renal fibrosis is the most common cause of allograft failure in kidney transplantations. Evaluation of renal abnormalities has progressed considerably over the past years. Currently, the diagnosis of intrarenal fibrosis and quantification of its development with non-invasive assessment tools is possible. This may help in early detection of renal allograft dysfunction. This study sought to assess the efficacy of 2D real-time shear-wave elastography (SWE) in the quantitative measurement of renal allograft dysfunction. Methods: A total of 172 patients were included in our study. SWE was performed in all these patients just before renal allograft biopsy. The cortical elasticity was assessed and described in terms of Young's modulus (kPa). Banff histopathological grading obtained from transplant kidney tissue biopsy was taken as the reference standard. The potential correlation between SWE scores and Banff classification was performed. Results: There was a significant correlation between the Banff grade and mean SWE score, with a correlation coefficient of 0.665 (p < 0.001). The individual correlation coefficients of interstitial fibrosis and tubular atrophy with mean SWE score stood at 0.667 and 0.649 respectively (p < 0.001). The correlation of resistive indices was insignificant when compared to mean polar SWE score in respective poles and the Banff grading of fibrosis. Conclusions: Renal stiffness quantified by 2D SWE showed significant correlation with histopathological renal fibrosis. Thus, the study suggests that shear-wave elastography could be used as a surrogate marker for early detection of renal fibrosis.
dc.contributor.authorpl
Chhajer, Gulab
dc.contributor.authorpl
Kasi Arunachalam, Venkatesh
dc.contributor.authorpl
Ramasamy, Rajkumar
dc.contributor.authorpl
Mehta, Pankaj
dc.contributor.authorpl
Cherian, Mathew
dc.date.accessioned
2021-03-29T13:01:08Z
dc.date.available
2021-03-29T13:01:08Z
dc.date.issuedpl
2021
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e156
dc.description.physicalpl
e151-e156
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
86
dc.identifier.doipl
10.5114/pjr.2021.104582
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/268241
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
elastography
dc.subject.enpl
SWE
dc.subject.enpl
renal transplant
dc.subject.enpl
transplant fibrosis
dc.subject.enpl
renal fibrosis
dc.subtypepl
Article
dc.titlepl
Elastography: a surrogate marker of renal allograft fibrosis : quantification by shear-wave technique
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
20
Views per month
Views per city
Ashburn
4
Dublin
4
Wroclaw
2
Brussels
1
Sofia
1
Downloads
chhajer_kasi-arunachalam_ramasamy_mehta_cherian_elastography_a_surrogate_marker_2021.pdf
9