Percutaneous removal of endocardial implantable cardioverter-defibrillator lead displaced to the right pulmonary artery

2010
journal article
article
dc.abstract.enWe describe a case of percutaneous removal of endocardial implantable cardioverter-defibrillator lead displaced to the right pulmonary artery. The procedure was performed from two accesses; from the lower one (femoral) and then, due to technical problems, from the upper one (subclavian). In the last stage the flattened Dotter’s basket was introduced to the heart inside the Byrd dilator and then fastened to the described lead as the external ‘splint’. This solution is an alternative to the recommended use of the internal metal leader with anchoring function in case of significant malformation of the internal lumen of the lead. The procedure we describe is an example of the sort of individual, original solution indispensable for the efficient and safe removal of untypically displaced leads.pl
dc.affiliationWydział Lekarski : Instytut Kardiologiipl
dc.contributor.authorMałecka, Barbara - 130836 pl
dc.contributor.authorKutarski, Andrzejpl
dc.contributor.authorZąbek, Andrzejpl
dc.contributor.authorMaziarz, Andrzejpl
dc.contributor.authorPytkowski, Mariuszpl
dc.date.accession2020-12-16pl
dc.date.accessioned2020-12-16T11:31:35Z
dc.date.available2020-12-16T11:31:35Z
dc.date.issued2010pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 298pl
dc.description.number3pl
dc.description.physical293-298pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume17pl
dc.identifier.eissn1898-018Xpl
dc.identifier.issn1897-5593pl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/259014
dc.identifier.weblinkhttps://journals.viamedica.pl/cardiology_journal/article/view/21382pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enpermanent stimulationpl
dc.subject.enlead displacementpl
dc.subject.enlead removalpl
dc.subtypeArticlepl
dc.titlePercutaneous removal of endocardial implantable cardioverter-defibrillator lead displaced to the right pulmonary arterypl
dc.title.journalCardiology Journalpl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
We describe a case of percutaneous removal of endocardial implantable cardioverter-defibrillator lead displaced to the right pulmonary artery. The procedure was performed from two accesses; from the lower one (femoral) and then, due to technical problems, from the upper one (subclavian). In the last stage the flattened Dotter’s basket was introduced to the heart inside the Byrd dilator and then fastened to the described lead as the external ‘splint’. This solution is an alternative to the recommended use of the internal metal leader with anchoring function in case of significant malformation of the internal lumen of the lead. The procedure we describe is an example of the sort of individual, original solution indispensable for the efficient and safe removal of untypically displaced leads.
dc.affiliationpl
Wydział Lekarski : Instytut Kardiologii
dc.contributor.authorpl
Małecka, Barbara - 130836
dc.contributor.authorpl
Kutarski, Andrzej
dc.contributor.authorpl
Ząbek, Andrzej
dc.contributor.authorpl
Maziarz, Andrzej
dc.contributor.authorpl
Pytkowski, Mariusz
dc.date.accessionpl
2020-12-16
dc.date.accessioned
2020-12-16T11:31:35Z
dc.date.available
2020-12-16T11:31:35Z
dc.date.issuedpl
2010
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 298
dc.description.numberpl
3
dc.description.physicalpl
293-298
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
17
dc.identifier.eissnpl
1898-018X
dc.identifier.issnpl
1897-5593
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/259014
dc.identifier.weblinkpl
https://journals.viamedica.pl/cardiology_journal/article/view/21382
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
permanent stimulation
dc.subject.enpl
lead displacement
dc.subject.enpl
lead removal
dc.subtypepl
Article
dc.titlepl
Percutaneous removal of endocardial implantable cardioverter-defibrillator lead displaced to the right pulmonary artery
dc.title.journalpl
Cardiology Journal
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.