Zastosowanie techniki LA ICP/MS w pierwiastkowej analizie próbek stałych

master
dc.abstract.enThe LA-ICP-MS technique is one of the most modern and efficient methods for direct analysis of qualitative, quantitative and isotopic composition of solids. However, its many advantages, quantitative analysis is difficult due to the lack of commercially available calibration standards. This limits the applicability of this technique. The purpose of this study was to improve the precision and accuracy of the quantification of Zn and Mg in rat brain tissue by the LA-ICP-MS technique and to draw up the concentration maps of these elements in the hippocampus area in depression studies.This purpose was achieved by applying: a) lyophilized matrix-matched standards based on spiked sample material, b) helium as a carrier gas having a lower density than argon, c) standardization of Zn and Mg signals with respect signals of the naturally occurring elements in the sample, which were carbon, sulfur and phosphorus.Based on the obtained results, it was shown that a comparison of mean concentrations of Zn and Mg in the rat brain is not sufficient to reveal the differences between the control sample and a brain tissue sample isolated from the rat bred on a zinc deficient diet. The local differences between the samples are only visible on the concentration maps of Zn and Mg in the rat brain hippocampus, so the distribution analysis is of great importance here and confirms the great potential of the LA-ICP-MS technique.pl
dc.abstract.plTechnika LA-ICP-MS jest jedną z najbardziej nowoczesnych i wydajnych metod do bezpośredniego określania składu jakościowego, ilościowego i izotopowego w ciałach stałych. Jednakże, pomimo jej wielu zalet, analiza ilościowa jest utrudniona z powodu braku komercyjnie dostępnych wzorców kalibracyjnych, co ogranicza stosowalność tej techniki. Celem niniejszej pracy było poprawienie precyzji i dokładności oznaczania Zn i Mg w tkance mózgowej szczura techniką LA-ICP-MS oraz sporządzenie map stężeniowych tych pierwiastków w obszarze hipokampu w badaniach dotyczących depresji.Wyznaczony cel zrealizowano poprzez zastosowanie: a) zliofilizowanych wzorców, sporządzonych w oparciu o materiał mózgowy wzbogacony w anality, b) helu jako gazu nośnego, posiadającego niższą gęstość w stosunku do argonu oraz c) standaryzacji sygnałów Zn i Mg względem pierwiastków naturalnie występujących w próbce, którymi były węgiel, siarka i fosfor.Na podstawie uzyskanych wyników, wykazano, iż porównanie średnich stężeń Zn i Mg w mózgu szczura nie jest wystarczające do wychwycenia różnic między próbką kontrolną, a próbką mózgu wyizolowaną ze szczura utrzymywanego na diecie ubogiej w cynk. Różnice lokalne między próbkami widoczne są dopiero na stężeniowych mapach rozmieszczenia badanych pierwiastków w hipokampie mózgu szczura, dzięki czemu analiza rozmieszczenia zyskuje tutaj ogromne znaczenie i potwierdza duże możliwości techniki LA-ICP-MS.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorWalas, Stanisław - 132508 pl
dc.contributor.authorGarncarz, Kingapl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerWalas, Stanisław - 132508 pl
dc.contributor.reviewerTelk, Anna - 156141 pl
dc.date.accessioned2020-07-27T05:22:55Z
dc.date.available2020-07-27T05:22:55Z
dc.date.submitted2017-06-21pl
dc.fieldofstudychemiapl
dc.identifier.apddiploma-112923-215657pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/218443
dc.languagepolpl
dc.subject.enLA-ICP-MS, rat brain tissue, bioimaging, mass spectrometrypl
dc.subject.plLA-ICP-MS, tkanka mózgowa szczura, analiza rozmieszczenia pierwiastkowego, spektrometria maspl
dc.titleZastosowanie techniki LA ICP/MS w pierwiastkowej analizie próbek stałychpl
dc.title.alternativeApplication of LA ICP/MS in elemental analysis of solid samplespl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The LA-ICP-MS technique is one of the most modern and efficient methods for direct analysis of qualitative, quantitative and isotopic composition of solids. However, its many advantages, quantitative analysis is difficult due to the lack of commercially available calibration standards. This limits the applicability of this technique. The purpose of this study was to improve the precision and accuracy of the quantification of Zn and Mg in rat brain tissue by the LA-ICP-MS technique and to draw up the concentration maps of these elements in the hippocampus area in depression studies.This purpose was achieved by applying: a) lyophilized matrix-matched standards based on spiked sample material, b) helium as a carrier gas having a lower density than argon, c) standardization of Zn and Mg signals with respect signals of the naturally occurring elements in the sample, which were carbon, sulfur and phosphorus.Based on the obtained results, it was shown that a comparison of mean concentrations of Zn and Mg in the rat brain is not sufficient to reveal the differences between the control sample and a brain tissue sample isolated from the rat bred on a zinc deficient diet. The local differences between the samples are only visible on the concentration maps of Zn and Mg in the rat brain hippocampus, so the distribution analysis is of great importance here and confirms the great potential of the LA-ICP-MS technique.
dc.abstract.plpl
Technika LA-ICP-MS jest jedną z najbardziej nowoczesnych i wydajnych metod do bezpośredniego określania składu jakościowego, ilościowego i izotopowego w ciałach stałych. Jednakże, pomimo jej wielu zalet, analiza ilościowa jest utrudniona z powodu braku komercyjnie dostępnych wzorców kalibracyjnych, co ogranicza stosowalność tej techniki. Celem niniejszej pracy było poprawienie precyzji i dokładności oznaczania Zn i Mg w tkance mózgowej szczura techniką LA-ICP-MS oraz sporządzenie map stężeniowych tych pierwiastków w obszarze hipokampu w badaniach dotyczących depresji.Wyznaczony cel zrealizowano poprzez zastosowanie: a) zliofilizowanych wzorców, sporządzonych w oparciu o materiał mózgowy wzbogacony w anality, b) helu jako gazu nośnego, posiadającego niższą gęstość w stosunku do argonu oraz c) standaryzacji sygnałów Zn i Mg względem pierwiastków naturalnie występujących w próbce, którymi były węgiel, siarka i fosfor.Na podstawie uzyskanych wyników, wykazano, iż porównanie średnich stężeń Zn i Mg w mózgu szczura nie jest wystarczające do wychwycenia różnic między próbką kontrolną, a próbką mózgu wyizolowaną ze szczura utrzymywanego na diecie ubogiej w cynk. Różnice lokalne między próbkami widoczne są dopiero na stężeniowych mapach rozmieszczenia badanych pierwiastków w hipokampie mózgu szczura, dzięki czemu analiza rozmieszczenia zyskuje tutaj ogromne znaczenie i potwierdza duże możliwości techniki LA-ICP-MS.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Walas, Stanisław - 132508
dc.contributor.authorpl
Garncarz, Kinga
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Walas, Stanisław - 132508
dc.contributor.reviewerpl
Telk, Anna - 156141
dc.date.accessioned
2020-07-27T05:22:55Z
dc.date.available
2020-07-27T05:22:55Z
dc.date.submittedpl
2017-06-21
dc.fieldofstudypl
chemia
dc.identifier.apdpl
diploma-112923-215657
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/218443
dc.languagepl
pol
dc.subject.enpl
LA-ICP-MS, rat brain tissue, bioimaging, mass spectrometry
dc.subject.plpl
LA-ICP-MS, tkanka mózgowa szczura, analiza rozmieszczenia pierwiastkowego, spektrometria mas
dc.titlepl
Zastosowanie techniki LA ICP/MS w pierwiastkowej analizie próbek stałych
dc.title.alternativepl
Application of LA ICP/MS in elemental analysis of solid samples
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
42
Views per month
Views per city
Krakow
7
Warsaw
6
Dublin
2
Wroclaw
2
Bielsko-Biala
1
Gdansk
1
Grodzisk Mazowiecki
1
Jawiszowice
1
Jaworki
1
Katowice
1

No access

No Thumbnail Available