Badania nad nowymi matrycami bioczujników opartymi na żelu tytanowym modyfikowanym nanostrukturami węglowymi

master
dc.abstract.enThe aim of this study was to examine biosensor matrices based on titania gel modified with carbon nanomaterials: multi-walled carbon nanotubes (MWCNTs) and mesoporous carbon CMK-3. Matrix composites were additionally enriched by PDDA (poly (diallyldimethylammonium)), gold nanoparticles (AuNPs), Nafion® and glutaraldehyde (GA). Tyrosinase was used as model active biological component. Cyclic voltammetry measurements were carried out in a catechol solution (o-hydroxybenzene) in the concentration range of 8.00 to 80.00 µmol•dm-3. Sensitivity of each biosensor composite and corresponding value of Michaelis-Menten constants, an indicator of biological affinity of biosensor to substrate, were estimated. The morphology of matrix nanocomposites was characterized by SEM images. For more detailed experiments biosensor with Tyr/TiO2/CMK-3/Nafion/PDDA (1.0 µl/electrode) matrix composite was selected, as it exhibited good mechanical strength, the highest sensitivity toward catechol and relatively low Michalelis-Menten constant. Analytical characteristics of proposed biosensor were evaluated with respect to sensitivity at low concentrations (1.35 µA•mol-1•dm3), linear range (5.06 - 23.46 µmol•dm-3), detection limit (0.42 µmol•dm-3), limit of quantification (1.26 µmol•dm-3), repeatability (RSD = 4.2%) and reproducibility (RSD = 3.4%).pl
dc.abstract.plCelem niniejszej pracy było zbadanie matryc biosensorów opartych na żelu ditlenku tytanu modyfikowanym nanostrukturalnymi materiałami węglowymi jakimi są wielościenne nanorurki węglowe (MWCNTs) oraz węgiel mezoporowaty CMK-3. Dodatkowymi składnikami matryc były również polikationit PDDA (chlorek poli(diallilodimetyloamoniowy)), nanocząstki złota, Nafion® oraz aldehyd glutarowy. Sprawdzono możliwość wykorzystania modyfikowanych zoli w konstrukcji bioczujników stosując tyrozynazę jako enzym modelowy. Wykonując pomiary woltamperometrii cyklicznej w roztworze pirokatechiny (o-hydroksybenzenu), w zakresie stężeń od 8,00 do 80,00 µmol•dm-3 oszacowano czułość każdego kompozytu, oraz wyznaczono wartości stałych Michaelisa-Menten, które są odzwierciedleniem powinowactwa unieruchomionego enzymu do analitu. Nanostrukturę zaproponowanych matryc badano wykorzystując skaningową mikroskopię elektronową (SEM). Na podstawie uzyskanych wyników dla badanych bioczujników wybrano ten, zawierający Tyr/TiO2/CMK-3/Nafion/PDDA(1,0 µl/elektr.), charakteryzujący się najlepszymi parametrami, takimi jak najwyższa wartość czułości, stosunkowo niska wartość stałej Michalelisa-Menten oraz wytrzymałość mechaniczna. Ostatnim etapem badań była charakterystyka analityczna wybranego bioczujnika, obejmująca wyznaczenie czułości w niskim zakresie stężeń (1,35 µA•µmol-1•dm3), zakresu liniowego (5,06 – 23,46 µmol•dm-3), granicy wykrywalności (0,42 µmol•dm-3), granicy oznaczalności (1,26 mol•dm-3), powtarzalności (RSD = 4,2%) oraz odtwarzalności (RSD = 3,4%).pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorKochana, Jolanta - 128954 pl
dc.contributor.authorStarzec, Karolinapl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerKochana, Jolanta - 128954 pl
dc.contributor.reviewerKozak, Joanna - 129327 pl
dc.date.accessioned2020-07-25T00:16:36Z
dc.date.available2020-07-25T00:16:36Z
dc.date.submitted2014-06-24pl
dc.fieldofstudychemiapl
dc.identifier.apddiploma-86559-166380pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/195208
dc.languagepolpl
dc.subject.enbiosensors, tyrosinase, titania gelpl
dc.subject.plbioczujniki, tyrozynaza, zol tytanowypl
dc.titleBadania nad nowymi matrycami bioczujników opartymi na żelu tytanowym modyfikowanym nanostrukturami węglowymipl
dc.title.alternativeBiosensor matrices based on titania gel modified with carbon nanomaterialspl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The aim of this study was to examine biosensor matrices based on titania gel modified with carbon nanomaterials: multi-walled carbon nanotubes (MWCNTs) and mesoporous carbon CMK-3. Matrix composites were additionally enriched by PDDA (poly (diallyldimethylammonium)), gold nanoparticles (AuNPs), Nafion® and glutaraldehyde (GA). Tyrosinase was used as model active biological component. Cyclic voltammetry measurements were carried out in a catechol solution (o-hydroxybenzene) in the concentration range of 8.00 to 80.00 µmol•dm-3. Sensitivity of each biosensor composite and corresponding value of Michaelis-Menten constants, an indicator of biological affinity of biosensor to substrate, were estimated. The morphology of matrix nanocomposites was characterized by SEM images. For more detailed experiments biosensor with Tyr/TiO2/CMK-3/Nafion/PDDA (1.0 µl/electrode) matrix composite was selected, as it exhibited good mechanical strength, the highest sensitivity toward catechol and relatively low Michalelis-Menten constant. Analytical characteristics of proposed biosensor were evaluated with respect to sensitivity at low concentrations (1.35 µA•mol-1•dm3), linear range (5.06 - 23.46 µmol•dm-3), detection limit (0.42 µmol•dm-3), limit of quantification (1.26 µmol•dm-3), repeatability (RSD = 4.2%) and reproducibility (RSD = 3.4%).
dc.abstract.plpl
Celem niniejszej pracy było zbadanie matryc biosensorów opartych na żelu ditlenku tytanu modyfikowanym nanostrukturalnymi materiałami węglowymi jakimi są wielościenne nanorurki węglowe (MWCNTs) oraz węgiel mezoporowaty CMK-3. Dodatkowymi składnikami matryc były również polikationit PDDA (chlorek poli(diallilodimetyloamoniowy)), nanocząstki złota, Nafion® oraz aldehyd glutarowy. Sprawdzono możliwość wykorzystania modyfikowanych zoli w konstrukcji bioczujników stosując tyrozynazę jako enzym modelowy. Wykonując pomiary woltamperometrii cyklicznej w roztworze pirokatechiny (o-hydroksybenzenu), w zakresie stężeń od 8,00 do 80,00 µmol•dm-3 oszacowano czułość każdego kompozytu, oraz wyznaczono wartości stałych Michaelisa-Menten, które są odzwierciedleniem powinowactwa unieruchomionego enzymu do analitu. Nanostrukturę zaproponowanych matryc badano wykorzystując skaningową mikroskopię elektronową (SEM). Na podstawie uzyskanych wyników dla badanych bioczujników wybrano ten, zawierający Tyr/TiO2/CMK-3/Nafion/PDDA(1,0 µl/elektr.), charakteryzujący się najlepszymi parametrami, takimi jak najwyższa wartość czułości, stosunkowo niska wartość stałej Michalelisa-Menten oraz wytrzymałość mechaniczna. Ostatnim etapem badań była charakterystyka analityczna wybranego bioczujnika, obejmująca wyznaczenie czułości w niskim zakresie stężeń (1,35 µA•µmol-1•dm3), zakresu liniowego (5,06 – 23,46 µmol•dm-3), granicy wykrywalności (0,42 µmol•dm-3), granicy oznaczalności (1,26 mol•dm-3), powtarzalności (RSD = 4,2%) oraz odtwarzalności (RSD = 3,4%).
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Kochana, Jolanta - 128954
dc.contributor.authorpl
Starzec, Karolina
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Kochana, Jolanta - 128954
dc.contributor.reviewerpl
Kozak, Joanna - 129327
dc.date.accessioned
2020-07-25T00:16:36Z
dc.date.available
2020-07-25T00:16:36Z
dc.date.submittedpl
2014-06-24
dc.fieldofstudypl
chemia
dc.identifier.apdpl
diploma-86559-166380
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/195208
dc.languagepl
pol
dc.subject.enpl
biosensors, tyrosinase, titania gel
dc.subject.plpl
bioczujniki, tyrozynaza, zol tytanowy
dc.titlepl
Badania nad nowymi matrycami bioczujników opartymi na żelu tytanowym modyfikowanym nanostrukturami węglowymi
dc.title.alternativepl
Biosensor matrices based on titania gel modified with carbon nanomaterials
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
11
Views per month
Views per city
Siemianowice Śląskie
2
Warsaw
2
Wroclaw
2
Dublin
1
Gdansk
1
Krakow
1
Shanghai
1

No access

No Thumbnail Available