Opracowanie warunków pomiarowych do oznaczania wanadu w materiale biologicznym

licenciate
dc.abstract.enJoints are exposed to various types of injuries, diseases or age-related impairment of functionality. In this case, there is a need for an artificial joint or other type of implant which will improve the quality of patient’s life. They are typically made of various kinds of metallic alloys. An implant interacts with the body tissue, which causes the corrosion of an implant and transition of metal ions into the body. Thus there is a need of controlling the concentration of these metals in the organism. The aim of the study was to develop a method for determination of vanadium in tissues at low concentration levels. Analyses were made by a Graphite Furnace Atomic Absorption Spectrometry (GFAAS). In order to develop a method, the pork samples were tested, to which a known amount of vanadium was added. Pyrolysis temperature, atomization temperature, and the concentration of palladium modifier were optimized. Next the method was validated and the basic analytical parameters (the linear range of the calibration curve, sensitivity, the limits of detection and quantification, recovery and precision) were evaluated. Finally, the method was tested on samples from patients who were prepared for implantation.pl
dc.abstract.plStawy są narażone na różnego rodzaju urazy, choroby czy też ograniczenie funkcjonalności z wiekiem. W takim przypadku zachodzi konieczność zastosowania sztucznego stawu lub innego rodzaju implantu poprawiającego jakość życia pacjenta. Najczęściej wykonane one są z różnego rodzaju stopów metali. Taki wszczep w organizmie ulega oddziaływaniu z tkankami organizmu, co powoduje jego korozję i przechodzenie jonów metali. Zatem istnieje konieczność kontrolowania stężenia tych metali w organizmie. Celem badań było opracowanie metody oznaczenia wanadu w tkankach na niskich poziomach stężeń. W pierwszej kolejności zoptymalizowano warunki pomiarowe a następnie dokonano walidacji metody. Oznaczenia wykonywano za pomocą metody GFAAS. W celu opracowania metody przebadano próbki mięsa wieprzowego, do którego dodano pewną ilość wanadu. Zoptymalizowano temperaturę pyrolizy, temperaturę atomizacji, stężenie modyfikatora palladowego, wyznaczono zakres liniowy krzywej kalibracyjnej oraz czułość metody, granicę wykrywalności i oznaczalności, odzysk i precyzję. Następnie metodę sprawdzono na próbkach pobranych od pacjentów, którzy byli przygotowywani do wszczepienia implantu.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorHerman, Małgorzata - 128310 pl
dc.contributor.authorRóżycki, Filippl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerHerman, Małgorzata - 128310 pl
dc.contributor.reviewerPiekoszewski, Wojciech - 160149 pl
dc.date.accessioned2020-07-24T22:48:31Z
dc.date.available2020-07-24T22:48:31Z
dc.date.submitted2014-09-19pl
dc.fieldofstudychemiapl
dc.identifier.apddiploma-84982-144084pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/193829
dc.languagepolpl
dc.subject.enImplant; Vanadium, The modifier, GF –AAS; Validation of methodpl
dc.subject.plImplant; Wanad; Modyfikator; GF-AAS; Walidacja metodypl
dc.titleOpracowanie warunków pomiarowych do oznaczania wanadu w materiale biologicznympl
dc.title.alternativeDevelopment of measuring conditions for the determination of vanadium in biological materialpl
dc.typelicenciatepl
dspace.entity.typePublication
dc.abstract.enpl
Joints are exposed to various types of injuries, diseases or age-related impairment of functionality. In this case, there is a need for an artificial joint or other type of implant which will improve the quality of patient’s life. They are typically made of various kinds of metallic alloys. An implant interacts with the body tissue, which causes the corrosion of an implant and transition of metal ions into the body. Thus there is a need of controlling the concentration of these metals in the organism. The aim of the study was to develop a method for determination of vanadium in tissues at low concentration levels. Analyses were made by a Graphite Furnace Atomic Absorption Spectrometry (GFAAS). In order to develop a method, the pork samples were tested, to which a known amount of vanadium was added. Pyrolysis temperature, atomization temperature, and the concentration of palladium modifier were optimized. Next the method was validated and the basic analytical parameters (the linear range of the calibration curve, sensitivity, the limits of detection and quantification, recovery and precision) were evaluated. Finally, the method was tested on samples from patients who were prepared for implantation.
dc.abstract.plpl
Stawy są narażone na różnego rodzaju urazy, choroby czy też ograniczenie funkcjonalności z wiekiem. W takim przypadku zachodzi konieczność zastosowania sztucznego stawu lub innego rodzaju implantu poprawiającego jakość życia pacjenta. Najczęściej wykonane one są z różnego rodzaju stopów metali. Taki wszczep w organizmie ulega oddziaływaniu z tkankami organizmu, co powoduje jego korozję i przechodzenie jonów metali. Zatem istnieje konieczność kontrolowania stężenia tych metali w organizmie. Celem badań było opracowanie metody oznaczenia wanadu w tkankach na niskich poziomach stężeń. W pierwszej kolejności zoptymalizowano warunki pomiarowe a następnie dokonano walidacji metody. Oznaczenia wykonywano za pomocą metody GFAAS. W celu opracowania metody przebadano próbki mięsa wieprzowego, do którego dodano pewną ilość wanadu. Zoptymalizowano temperaturę pyrolizy, temperaturę atomizacji, stężenie modyfikatora palladowego, wyznaczono zakres liniowy krzywej kalibracyjnej oraz czułość metody, granicę wykrywalności i oznaczalności, odzysk i precyzję. Następnie metodę sprawdzono na próbkach pobranych od pacjentów, którzy byli przygotowywani do wszczepienia implantu.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Herman, Małgorzata - 128310
dc.contributor.authorpl
Różycki, Filip
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Herman, Małgorzata - 128310
dc.contributor.reviewerpl
Piekoszewski, Wojciech - 160149
dc.date.accessioned
2020-07-24T22:48:31Z
dc.date.available
2020-07-24T22:48:31Z
dc.date.submittedpl
2014-09-19
dc.fieldofstudypl
chemia
dc.identifier.apdpl
diploma-84982-144084
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/193829
dc.languagepl
pol
dc.subject.enpl
Implant; Vanadium, The modifier, GF –AAS; Validation of method
dc.subject.plpl
Implant; Wanad; Modyfikator; GF-AAS; Walidacja metody
dc.titlepl
Opracowanie warunków pomiarowych do oznaczania wanadu w materiale biologicznym
dc.title.alternativepl
Development of measuring conditions for the determination of vanadium in biological material
dc.typepl
licenciate
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
8
Views per month
Views per city
Dublin
3
Wroclaw
2
Poznan
1
Szczecin
1

No access

No Thumbnail Available