Zastosowanie metod pogłębionego utleniania modelowych zanieczyszczeń organicznych w ściekach.

master
dc.abstract.enThe effectiveness of the advanced oxidation processes using Fenton's system was studied in the removal of phenolic pollutants from water.Phenols present a threat to the environment. They are also dangerous to human and animal health. One of methods of removal of phenols from water and wastewater is oxidation by Fenton's reagent - H2O2/Fe2+. For the catalytic tests, acid–treated vermiculite and vermiculite-based catalysts modified with iron were synthesized. Then a series of tests was conducted to compare the catalytic activity of the obtained catalysts. The next stage of research was to determine the conditions under which the process was carried out on its effectiveness. It was shown that acid catalysts are much less active in the oxidation of phenol than catalysts doped with iron.Based on the experimental results it was found that increasing the efficiency of the process can be achieved by factors such as increased iron content in the catalyst, increasing the temperature and lowering pH. Increasing the iron content increases the amount of unwanted intermediates. Change in products distribution was also observed in reactions conducted in the presence of light and without irradiation. The highest efficiency was observed for the experiments in which the oxidant was introduced gradually, in small portions.pl
dc.abstract.plZbadano skuteczność metody pogłębionego utleniania za pomocą układu Fentona w oczyszczaniu wody z zanieczyszczeń fenolowych. Fenole obecne w wodach stanowią zagrożenie dla środowiska naturalnego oraz dla zdrowia ludzi i zwierząt. Jedną z metod usuwania fenolu z wód i ścieków jest utlenianie mieszaniną Fentona - H2O2/Fe2+. Do przeprowadzenia testów katalitycznych zsyntetyzowano katalizatory wermikulitowe traktowane kwasami oraz modyfikowane żelazem. Następnie przeprowadzono serię testów katalitycznych w celu porównania aktywności otrzymanych katalizatorów. Kolejnym etapem badań było określenie wpływu warunków, w jakich prowadzono proces na jego efektywność.Na podstawie przeprowadzonych badań stwierdzono, że wzrost efektywności procesu powodują takie czynniki, jak: wzrost zawartości żelaza w katalizatorze, zwiększenie temperatury oraz obniżenie pH. Wzrastająca zawartość żelaza zwiększa ilość niepożądanych produktów przejściowych. Zmianę dystrybucji produktów zaobserwowano także w reakcjach prowadzonych w obecności światła i bez naświetlania. Największą efektywność procesu zaobserwowano dla testów, w których utleniacz był wprowadzany stopniowo, w małych porcjachpl
dc.affiliationWydział Chemiipl
dc.contributor.advisorWęgrzyn, Agnieszka - 132595 pl
dc.contributor.authorZych, Agatapl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerMakowski, Wacław - 100616 pl
dc.contributor.reviewerWęgrzyn, Agnieszka - 132595 pl
dc.date.accessioned2020-07-23T23:18:07Z
dc.date.available2020-07-23T23:18:07Z
dc.date.submitted2012-06-15pl
dc.fieldofstudychemia środowiskapl
dc.identifier.apddiploma-65026-80591pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/178552
dc.languagepolpl
dc.subject.enAOPs, Fenton’s reagent, phenols, vermiculitepl
dc.subject.plAOP, odczynnik Fentona, fenole, wermikulitpl
dc.titleZastosowanie metod pogłębionego utleniania modelowych zanieczyszczeń organicznych w ściekach.pl
dc.title.alternativeApplication of Advanced Oxidation Methods of Model Organic Pollutants in Wastewater.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The effectiveness of the advanced oxidation processes using Fenton's system was studied in the removal of phenolic pollutants from water.Phenols present a threat to the environment. They are also dangerous to human and animal health. One of methods of removal of phenols from water and wastewater is oxidation by Fenton's reagent - H2O2/Fe2+. For the catalytic tests, acid–treated vermiculite and vermiculite-based catalysts modified with iron were synthesized. Then a series of tests was conducted to compare the catalytic activity of the obtained catalysts. The next stage of research was to determine the conditions under which the process was carried out on its effectiveness. It was shown that acid catalysts are much less active in the oxidation of phenol than catalysts doped with iron.Based on the experimental results it was found that increasing the efficiency of the process can be achieved by factors such as increased iron content in the catalyst, increasing the temperature and lowering pH. Increasing the iron content increases the amount of unwanted intermediates. Change in products distribution was also observed in reactions conducted in the presence of light and without irradiation. The highest efficiency was observed for the experiments in which the oxidant was introduced gradually, in small portions.
dc.abstract.plpl
Zbadano skuteczność metody pogłębionego utleniania za pomocą układu Fentona w oczyszczaniu wody z zanieczyszczeń fenolowych. Fenole obecne w wodach stanowią zagrożenie dla środowiska naturalnego oraz dla zdrowia ludzi i zwierząt. Jedną z metod usuwania fenolu z wód i ścieków jest utlenianie mieszaniną Fentona - H2O2/Fe2+. Do przeprowadzenia testów katalitycznych zsyntetyzowano katalizatory wermikulitowe traktowane kwasami oraz modyfikowane żelazem. Następnie przeprowadzono serię testów katalitycznych w celu porównania aktywności otrzymanych katalizatorów. Kolejnym etapem badań było określenie wpływu warunków, w jakich prowadzono proces na jego efektywność.Na podstawie przeprowadzonych badań stwierdzono, że wzrost efektywności procesu powodują takie czynniki, jak: wzrost zawartości żelaza w katalizatorze, zwiększenie temperatury oraz obniżenie pH. Wzrastająca zawartość żelaza zwiększa ilość niepożądanych produktów przejściowych. Zmianę dystrybucji produktów zaobserwowano także w reakcjach prowadzonych w obecności światła i bez naświetlania. Największą efektywność procesu zaobserwowano dla testów, w których utleniacz był wprowadzany stopniowo, w małych porcjach
dc.affiliationpl
Wydział Chemii
dc.contributor.advisorpl
Węgrzyn, Agnieszka - 132595
dc.contributor.authorpl
Zych, Agata
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Makowski, Wacław - 100616
dc.contributor.reviewerpl
Węgrzyn, Agnieszka - 132595
dc.date.accessioned
2020-07-23T23:18:07Z
dc.date.available
2020-07-23T23:18:07Z
dc.date.submittedpl
2012-06-15
dc.fieldofstudypl
chemia środowiska
dc.identifier.apdpl
diploma-65026-80591
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/178552
dc.languagepl
pol
dc.subject.enpl
AOPs, Fenton’s reagent, phenols, vermiculite
dc.subject.plpl
AOP, odczynnik Fentona, fenole, wermikulit
dc.titlepl
Zastosowanie metod pogłębionego utleniania modelowych zanieczyszczeń organicznych w ściekach.
dc.title.alternativepl
Application of Advanced Oxidation Methods of Model Organic Pollutants in Wastewater.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
10
Views per month
Views per city
Wroclaw
4
Auckland
1
Dublin
1
Gdansk
1
Szczecin
1
Warsaw
1

No access

No Thumbnail Available