Zastosowanie metod katalitycznych do usuwania zanieczyszczeń organicznych ze ścieków koksowniczych.

master
dc.abstract.enRemoval of organic pollutants from coke plants effluents was studied. Coking is a process, in which is formed high volume industrial wastewater. It contains volatile phenols, tar, oils, polycyclic aromatic hydrocarbons, pyridine, cyanides and nitriles. The most toxic compounds are phenols. In order to remove them three different catalysts, copper or iron doped were used: hydrotalcite, ion exchanged resin and bentonite. Following methods were used for samples characterization: X ray diffraction, AAS and UV-Vis spectrophotometry. A series of catalytic tests in the presence of hydrogen peroxide using a solution of phenol, catechin, benzoquinone or a sample of the wastewater from the biological treatment plant (Arcelor Mittal Poland S.A.) were performed. Several parametrs were determined: pH, permanganate index, COD (Cr). Identification of organic compounds and cyanides present in effluent, reaction mixture and samples of distillates, was done, mainly by means of GC and spectrophotometry. Analyzing of catalytic tests results, it was found that for resins a high consumption of hydrogen peroxide takes place, and nearly complete in case of application of hydrotalcite. It was also found to that concentration of phenol was reduced during reaction. During the test decrease in values of COD (Cr) and permanganate index was observed in reaction mixture comparing to reference sample.pl
dc.abstract.plZbadano usuwanie zanieczyszczeń organicznych ze ścieków koksowniczych. Koksowanie jest procesem, w którym powstaje duża ilość ścieków przemysłowych. Zawierają one fenole lotne, smoły, oleje, wielopierścieniowe węglowodory aromatyczne, pirydynę, cyjanki i nitryle. Najbardziej toksyczne są fenole. W celu usunięcia ich trzy różne katalizatory, dotowane miedzią lub żelazem, zostały wykorzystane: hydrotalkit, żywica jonowymienna i bentonit. Do charakterystyki próbek wykorzystywano następujące metody: dyfrakcję promieni rentgenowskich, ASA i spektrofotometrię UV-Vis.Przeprowadzono serię testów katalitycznych w obecności nadtlenku wodoru, stosując roztwory fenolu, pirokatechiny, benzochinonu lub próbki ścieków z oczyszczalni biologicznej (Arcelor Mittal Polska SA). Oznaczano następujące parametry: pH, indeks nadmanganianowy, ChZT (Cr). Identyfikacja związków organicznych i cyjanków, obecnych w ściekach, mieszaninie reakcyjnej i próbkach destylatów została wykonana głównie za pomocą chromatografii gazowej i spektrometrii.Analizując wyniki badań, zaobserwowano wysoką konwersję nadtlenku wodoru na żywicach, i prawie całkowitą w przypadku stosowania hydrotalkitu. Stwierdzono również, że stężenia fenolu znacznie zmniejszają się w trakcie reakcji. Podczas testu zaobserwowano spadek wartości ChZT (Cr) i indeksu nadmanganianowego dla mieszaniny reakcyjnej w porównaniu do próbki odniesienia.pl
dc.affiliationWydział Chemiipl
dc.contributor.advisorWęgrzyn, Agnieszka - 132595 pl
dc.contributor.authorZybura, Paulapl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerWęgrzyn, Agnieszka - 132595 pl
dc.contributor.reviewerChmielarz, Lucjan - 127527 pl
dc.date.accessioned2020-07-15T18:16:21Z
dc.date.available2020-07-15T18:16:21Z
dc.date.submitted2011-07-15pl
dc.fieldofstudychemia środowiskapl
dc.identifier.apddiploma-59071-63424pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/172907
dc.languagepolpl
dc.subject.enHydrotalcite, ion exchanged resin, treatment, phenolpl
dc.subject.plHydrotalkit, żywica jonowymienna, oczyszczanie, fenolpl
dc.titleZastosowanie metod katalitycznych do usuwania zanieczyszczeń organicznych ze ścieków koksowniczych.pl
dc.title.alternativeThe application of catalytic methods for removing organic pollutants from coking waste water.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
Removal of organic pollutants from coke plants effluents was studied. Coking is a process, in which is formed high volume industrial wastewater. It contains volatile phenols, tar, oils, polycyclic aromatic hydrocarbons, pyridine, cyanides and nitriles. The most toxic compounds are phenols. In order to remove them three different catalysts, copper or iron doped were used: hydrotalcite, ion exchanged resin and bentonite. Following methods were used for samples characterization: X ray diffraction, AAS and UV-Vis spectrophotometry. A series of catalytic tests in the presence of hydrogen peroxide using a solution of phenol, catechin, benzoquinone or a sample of the wastewater from the biological treatment plant (Arcelor Mittal Poland S.A.) were performed. Several parametrs were determined: pH, permanganate index, COD (Cr). Identification of organic compounds and cyanides present in effluent, reaction mixture and samples of distillates, was done, mainly by means of GC and spectrophotometry. Analyzing of catalytic tests results, it was found that for resins a high consumption of hydrogen peroxide takes place, and nearly complete in case of application of hydrotalcite. It was also found to that concentration of phenol was reduced during reaction. During the test decrease in values of COD (Cr) and permanganate index was observed in reaction mixture comparing to reference sample.
dc.abstract.plpl
Zbadano usuwanie zanieczyszczeń organicznych ze ścieków koksowniczych. Koksowanie jest procesem, w którym powstaje duża ilość ścieków przemysłowych. Zawierają one fenole lotne, smoły, oleje, wielopierścieniowe węglowodory aromatyczne, pirydynę, cyjanki i nitryle. Najbardziej toksyczne są fenole. W celu usunięcia ich trzy różne katalizatory, dotowane miedzią lub żelazem, zostały wykorzystane: hydrotalkit, żywica jonowymienna i bentonit. Do charakterystyki próbek wykorzystywano następujące metody: dyfrakcję promieni rentgenowskich, ASA i spektrofotometrię UV-Vis.Przeprowadzono serię testów katalitycznych w obecności nadtlenku wodoru, stosując roztwory fenolu, pirokatechiny, benzochinonu lub próbki ścieków z oczyszczalni biologicznej (Arcelor Mittal Polska SA). Oznaczano następujące parametry: pH, indeks nadmanganianowy, ChZT (Cr). Identyfikacja związków organicznych i cyjanków, obecnych w ściekach, mieszaninie reakcyjnej i próbkach destylatów została wykonana głównie za pomocą chromatografii gazowej i spektrometrii.Analizując wyniki badań, zaobserwowano wysoką konwersję nadtlenku wodoru na żywicach, i prawie całkowitą w przypadku stosowania hydrotalkitu. Stwierdzono również, że stężenia fenolu znacznie zmniejszają się w trakcie reakcji. Podczas testu zaobserwowano spadek wartości ChZT (Cr) i indeksu nadmanganianowego dla mieszaniny reakcyjnej w porównaniu do próbki odniesienia.
dc.affiliationpl
Wydział Chemii
dc.contributor.advisorpl
Węgrzyn, Agnieszka - 132595
dc.contributor.authorpl
Zybura, Paula
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Węgrzyn, Agnieszka - 132595
dc.contributor.reviewerpl
Chmielarz, Lucjan - 127527
dc.date.accessioned
2020-07-15T18:16:21Z
dc.date.available
2020-07-15T18:16:21Z
dc.date.submittedpl
2011-07-15
dc.fieldofstudypl
chemia środowiska
dc.identifier.apdpl
diploma-59071-63424
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/172907
dc.languagepl
pol
dc.subject.enpl
Hydrotalcite, ion exchanged resin, treatment, phenol
dc.subject.plpl
Hydrotalkit, żywica jonowymienna, oczyszczanie, fenol
dc.titlepl
Zastosowanie metod katalitycznych do usuwania zanieczyszczeń organicznych ze ścieków koksowniczych.
dc.title.alternativepl
The application of catalytic methods for removing organic pollutants from coking waste water.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
13
Views per month
Views per city
Krakow
5
Wroclaw
2
Debe Wielkie
1
Lębork
1
Tychy
1
Zielonki
1

No access

No Thumbnail Available