Metoda odzysku i możliwości jej wykorzystania w analizie próbek środowiskowych.

master
dc.abstract.enThe recovery method is used for rating of accuracy. In literature (e.g. IUPAC technical reports) recovery (RV) is correlated only with preparation samples for measurement. In fact, RV depends on occurrence of interference effects. In this thesis it has been demonstrated that not only effects occurring during preparation sample for measurement affect recovery, but also interference effects. Impact of incorporation recovery into analytical result on accuracy has also been explored. At first, mathematic model permitting quantifies impact of preparation and interference effect on recovery has been compiled. Subsequently model and real research on effects which may occur during analytical procedure has been done in order to verify correctness of received theoretical argument.Flow injection system for estimating of recovery has also been constructed.pl
dc.abstract.otherMetoda odzysku jest stosowana do oceny dokładności wyników analitycznych. W literaturze (np. w dokumentach technicznych IUPAC) stopień odzysku analitu (RV) jest korelowany jedynie z etapem przygotowania próbki do pomiaru. W rzeczywistości, wartość RV zależy także od występowania efektów interferencyjnych. W niniejszej pracy wykazano, że nie tylko efekty występujące podczas przygotowania próbki do pomiaru, ale także efekty interferencyjne mają wpływ na wartość stopnia odzysku analitu. Zbadano także wpływ uwzględnienia wartości RV na dokładność wyników analitycznych. Początkowo opracowano model matematyczny, umożliwiający określenie wpływu efektów mogących wystąpić w toku procedury analitycznej na wartość stopnia odzysku analitu. Następnie przeprowadzono badania modelowych i rzeczywistych efektów, mogących wystąpić w toku procedury analitycznej w celu weryfikacji poprawności przyjętego rozumowania teoretycznego. Skonstruowano także układ wstrzykowo-przepływowy umożliwiający wyznaczenie stopnia odzysku analitu.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorWieczorek, Marcin - 160176 pl
dc.contributor.authorJanicki, Piotrpl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerKościelniak, Paweł - 129217 pl
dc.contributor.reviewerWieczorek, Marcin - 160176 pl
dc.date.accessioned2020-07-14T18:20:54Z
dc.date.available2020-07-14T18:20:54Z
dc.date.submitted2011-06-17pl
dc.fieldofstudychemiapl
dc.identifier.apddiploma-54922-61941pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/169867
dc.subject.enchemical analysis, recovery method, recovery, accuracypl
dc.subject.otheranaliza chemiczna, metoda odzysku, odzysk, dokładnośćpl
dc.titleMetoda odzysku i możliwości jej wykorzystania w analizie próbek środowiskowych.pl
dc.title.alternativeThe recovery method and its usefulness in analysis of environmental samples.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The recovery method is used for rating of accuracy. In literature (e.g. IUPAC technical reports) recovery (RV) is correlated only with preparation samples for measurement. In fact, RV depends on occurrence of interference effects. In this thesis it has been demonstrated that not only effects occurring during preparation sample for measurement affect recovery, but also interference effects. Impact of incorporation recovery into analytical result on accuracy has also been explored. At first, mathematic model permitting quantifies impact of preparation and interference effect on recovery has been compiled. Subsequently model and real research on effects which may occur during analytical procedure has been done in order to verify correctness of received theoretical argument.Flow injection system for estimating of recovery has also been constructed.
dc.abstract.otherpl
Metoda odzysku jest stosowana do oceny dokładności wyników analitycznych. W literaturze (np. w dokumentach technicznych IUPAC) stopień odzysku analitu (RV) jest korelowany jedynie z etapem przygotowania próbki do pomiaru. W rzeczywistości, wartość RV zależy także od występowania efektów interferencyjnych. W niniejszej pracy wykazano, że nie tylko efekty występujące podczas przygotowania próbki do pomiaru, ale także efekty interferencyjne mają wpływ na wartość stopnia odzysku analitu. Zbadano także wpływ uwzględnienia wartości RV na dokładność wyników analitycznych. Początkowo opracowano model matematyczny, umożliwiający określenie wpływu efektów mogących wystąpić w toku procedury analitycznej na wartość stopnia odzysku analitu. Następnie przeprowadzono badania modelowych i rzeczywistych efektów, mogących wystąpić w toku procedury analitycznej w celu weryfikacji poprawności przyjętego rozumowania teoretycznego. Skonstruowano także układ wstrzykowo-przepływowy umożliwiający wyznaczenie stopnia odzysku analitu.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Wieczorek, Marcin - 160176
dc.contributor.authorpl
Janicki, Piotr
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Kościelniak, Paweł - 129217
dc.contributor.reviewerpl
Wieczorek, Marcin - 160176
dc.date.accessioned
2020-07-14T18:20:54Z
dc.date.available
2020-07-14T18:20:54Z
dc.date.submittedpl
2011-06-17
dc.fieldofstudypl
chemia
dc.identifier.apdpl
diploma-54922-61941
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/169867
dc.subject.enpl
chemical analysis, recovery method, recovery, accuracy
dc.subject.otherpl
analiza chemiczna, metoda odzysku, odzysk, dokładność
dc.titlepl
Metoda odzysku i możliwości jej wykorzystania w analizie próbek środowiskowych.
dc.title.alternativepl
The recovery method and its usefulness in analysis of environmental samples.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
57
Views per month
Views per city
Warsaw
12
Krakow
9
Wroclaw
8
Dublin
2
Gdynia
2
Gliwice
2
Myślenice
2
Szczecin
2
Ashburn
1
Budapest
1

No access

No Thumbnail Available