Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes

2019
journal article
article
7
cris.lastimport.wos2024-04-10T01:37:21Z
dc.abstract.enPurpose: We aimed to determine the contribution of the apparent diffusion coefficient (ADC) value in the detection of axillary lymph node metastasis. Material and methods: Breast magnetic resonance of 58 patients, performed in the radiology clinic of our hospital between 2015 and 2017 were examined retrospectively, and 43 lymph nodes in 43 patients were included in the study. They were evaluated morphologically on T1W and T2W sequences, and the lymph nodes showing rounded shape, focal or diffuse cortical thickness of more than 3 mm, and partial or total effacement of fatty hilum were included in the study. Subsequently, their ADC values were measured. Results: There were 43 lymph nodes, 20 of which were malignant and 23 of which were benign. While the mean ADC value of malignant axillary lymph nodes was 0.749 10-3 mm2/s (0.48-1.342), it was 0.982 10-3 mm2/s (0.552-1.986) for benign lymph nodes. When the ADC cut-off value was taken as ≤ 0.753 × 10-3 mm2/s, its discrimination power between benign and malignant axillary lymph nodes was as follows: sensitivity - 60%; specificity - 91.3%; accuracy - 76.7%; positive predictive value - 85.7%; and negative predictive value - 72.4%. Conclusions: There was no significant difference between mean ADC value of 12 lymphadenopathies (LAP) associated with inflammatory breast diseases (granulomatous mastitis and acute suppurative mastitis) and mean ADC value of metastatic lymph nodes. However, the ADC value of lymph nodes showing thickened cortex due to systemic inflammatory diseases was over 1, and there was a statistically significant difference when compared with metastatic lymph nodes.pl
dc.contributor.authorYılmaz, Ebrupl
dc.contributor.authorErok, Berrinpl
dc.contributor.authorAtca, Ali Önderpl
dc.date.accessioned2020-01-21T10:50:27Z
dc.date.available2020-01-21T10:50:27Z
dc.date.issued2019pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e597pl
dc.description.physicale592-e597pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume84pl
dc.identifier.doi10.5114/pjr.2019.92315pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/146906
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enaxillary LAPpl
dc.subject.enbreast cancerpl
dc.subject.endiffusion-weighted imaging (DWI)pl
dc.subject.enapparent diffusion coefficient (ADC)pl
dc.subtypeArticlepl
dc.titleMeasurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodespl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T01:37:21Z
dc.abstract.enpl
Purpose: We aimed to determine the contribution of the apparent diffusion coefficient (ADC) value in the detection of axillary lymph node metastasis. Material and methods: Breast magnetic resonance of 58 patients, performed in the radiology clinic of our hospital between 2015 and 2017 were examined retrospectively, and 43 lymph nodes in 43 patients were included in the study. They were evaluated morphologically on T1W and T2W sequences, and the lymph nodes showing rounded shape, focal or diffuse cortical thickness of more than 3 mm, and partial or total effacement of fatty hilum were included in the study. Subsequently, their ADC values were measured. Results: There were 43 lymph nodes, 20 of which were malignant and 23 of which were benign. While the mean ADC value of malignant axillary lymph nodes was 0.749 10-3 mm2/s (0.48-1.342), it was 0.982 10-3 mm2/s (0.552-1.986) for benign lymph nodes. When the ADC cut-off value was taken as ≤ 0.753 × 10-3 mm2/s, its discrimination power between benign and malignant axillary lymph nodes was as follows: sensitivity - 60%; specificity - 91.3%; accuracy - 76.7%; positive predictive value - 85.7%; and negative predictive value - 72.4%. Conclusions: There was no significant difference between mean ADC value of 12 lymphadenopathies (LAP) associated with inflammatory breast diseases (granulomatous mastitis and acute suppurative mastitis) and mean ADC value of metastatic lymph nodes. However, the ADC value of lymph nodes showing thickened cortex due to systemic inflammatory diseases was over 1, and there was a statistically significant difference when compared with metastatic lymph nodes.
dc.contributor.authorpl
Yılmaz, Ebru
dc.contributor.authorpl
Erok, Berrin
dc.contributor.authorpl
Atca, Ali Önder
dc.date.accessioned
2020-01-21T10:50:27Z
dc.date.available
2020-01-21T10:50:27Z
dc.date.issuedpl
2019
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e597
dc.description.physicalpl
e592-e597
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
84
dc.identifier.doipl
10.5114/pjr.2019.92315
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/146906
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
axillary LAP
dc.subject.enpl
breast cancer
dc.subject.enpl
diffusion-weighted imaging (DWI)
dc.subject.enpl
apparent diffusion coefficient (ADC)
dc.subtypepl
Article
dc.titlepl
Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
20
Views per month
Views per city
Hong Kong
6
Ashburn
3
Dublin
3
Wroclaw
2
Boardman
1
Des Moines
1
Downloads
yilmaz_erok_atca_measurement_of_apparent_diffusion_coefficient_2019.pdf
16
yilmaz_erok_atca_measurement_of_apparent_diffusion_coefficient_2019.odt
10