Dental and skeletal changes after intra-oral molar distalization using a "Distal Driver" appliance : a pilot study

2016
journal article
article
cris.lastimport.wos2024-04-09T20:48:39Z
dc.abstract.enIntroduction. Loss of space in the maxillary arch is a frequent consequence of early loss of deciduous molars indicating distalisation of the mesialised molar tooth. A number of methods using either extra-oral appliances or intra oral appliances of various types have been suggested. While extra-oral appliances exert a high but intermittent force many of the intraoral ones deliver a modest, though constant, force and demands no patient cooperation. Aim of study. To investigate the effect of an intra-oral fixed appliance (Distal Driver) based on a NiTi spring incorporating also a standardised anchorage unit on the position of the maxillary first molar as well as on the facial skeleton and the dentition in general. Material and methods. The experimental group comprised 6 child patients exhibiting a distal molar relationship (Unilateral or Bilateral) of at least ½ premolar unit. The mesialised molars were distalised by means of a “Distal Driver” exerting a force of 150 gm for a period of 3-4 weeks. Anchorage was created by a fixed modified palatal bar cemented on the premolars supporting an acrylic palatal button ad modum Nance. The clinical situation was recorded before and after molar distalisation by means of study casts, cephalograms, panoramic radiographs as well as intra-oral photographs. The distalisation of the molars as well as the effect on anchorage teeth was quantitated on digital models derived from the plaster casts. Evaluation of the observed distal and vertical changes in molar position was performed on the lateral cephalogram. Results. Cast analysis showed a clear distalising effect on the maxillary first molars ranging from 1.25 mm to 6.18 mm as well as mesial movement of the premolar anchorage teeth from 0.46 mm to 5.55mm. The cephalometric analysis revealed a first molar distalisation of 0.9 mm to 5.6 mm though again with a mesial movement of the first premolar varying from 0.5 mm to 3.7 mm. A clear distal tipping of the first and second molars simultaneously with a mesial tipping of the first premolars was also recorded. Conclusion. The Distal Driver constitutes an efficient method of maxillary molar distalisation though is often accompanied by a distal rotation of these teeth and a mesial tipping of the anchorage premolars. Careful monitoring of anchorage loss is necessary if good results are to be achieved.pl
dc.abstract.plWstęp. Niedobór miejsca w górnym łuku zębowym będący często konsekwencją przedwczesnej utraty zębów trzonowych mlecznych, wskazuje na konieczność dystalizacji przemieszczonych mezjalnie stałych pierwszych zębów trzonowych. Dostępnych jest wiele metod uwzględniających użycie aparatów zewnątrzustnch bądź różnego typu aparatów wewnątrzustnych. Podczas gdy aparaty zewnątrzustne dostarczają znacznej, lecz przerywanej siły, aparaty wewnątrzustne działają wywołując średnie poziomy sił nawet przy braku współpracy ze strony pacjenta. Cel badania. Celem badania była ocena efektywności wewnątrzustnego stałego aparatu (Distal Driver) opartego na otwartej sprężynce NiTi oraz standardowej jednostce kotwiącej w dystalizacji pierwszych zębów trzonowych szczęki oraz jego wpływu na struktury szkieletowe i zębowe. Materiał i metoda. Grupa badawcza składała się z 6 pacjentów w wieku dziecięcym demonstrujących dystalną relację zębów trzonowych (jednostronnie lub obustronnie) w zakresie przynajmniej ½ jednostki. Mezjalnie przemieszczone zęby trzonowe zdystalizowano aparatem „Distal Driver” wywierając siłę 150g przez okres 3-4 tygodni. Zakotwienie uzyskano stosując przerzut podniebienny cementowany do pierwszych zębów przedtrzonowych oraz wzmocniony guziczkiem podniebiennym na wzór aparatu Nance. Przed leczeniem oraz po zakończeniu dystalizacji wykonano dokumentację w postaci modeli, zdjęć cefalometrycznych, zdjęć pantomograficznych oraz zdjęć fotograficznych wewnątrzustnych. Dystalizacja pierwszych zębów trzonowych oraz zmiany w położeniu zębów jednostki kotwiącej zostały ocenione na modelach cyfrowych otrzymanych na podstawie skanu modeli gipsowych. Pomiaru dystalizacji oraz zmian w pionowym położeniu zębów trzonowych dokonano na zdjęciach cefalometrycznych. Wyniki. Analiza modeli wykazała dystalizację pierwszych zębów trzonowych szczęki w zakresie od 1,25 mm do 6,18 mm oraz mezjalizację zębów przedtrzonowych włączonych do jednostki kotwiącej wielkości od 0,46 mm do 5,55mm. Zgodnie z analizą cefalometryczną uzyskano od 0,9mm do 5,6mm dystalizacji pierwszych zębów trzonowych kosztem od 0.5mm do 3.7mm mezjalizacji zębów przedtrzonowych. Odnotowano także dystalne nachylenie pierwszych i drugich zębów trzonowych z jednoczesnym mezjalnym nachyleniem pierwszych zębów przedtrzonowych. Wnioski. Aparat “Distal Driver” stanowi efektywną metodę dystalizacji pierwszych zębów trzonowych szczęki, jednak jego działaniu często towarzyszą efekty uboczne w postaci dystorotacji tych zębów oraz mezjalnego nachylenia zębów przedtrzonowych jednostki kotwiącej. W celu uzyskania pożądanych rezultatów wskazana jest uważna kontrola utraty zakotwienia.pl
dc.affiliationWydział Lekarski : Instytut Stomatologiipl
dc.cm.date2020-01-07
dc.cm.id80452
dc.contributor.authorUrbaniak-Malinowska, Gabrielapl
dc.contributor.authorGibas-Stanek, Marta - 357858 pl
dc.contributor.authorWilliams, Stephen - 213994 pl
dc.contributor.authorStós, Wojciech - 133518 pl
dc.contributor.authorLoster, Bartłomiej - 130712 pl
dc.date.accession2020-09-22pl
dc.date.accessioned2020-01-17T09:14:14Z
dc.date.available2020-01-17T09:14:14Z
dc.date.issued2016pl
dc.date.openaccess0
dc.description.accesstimepo opublikowaniu
dc.description.additionalTekst równolegle w j. pol i j .ang. Bibliogr. s. 710-711pl
dc.description.number6pl
dc.description.physical695-711pl
dc.description.points12pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume69pl
dc.identifier.doi10.5604/00114553.1230590pl
dc.identifier.eissn2299-551Xpl
dc.identifier.issn0011-4553pl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/139607
dc.identifier.weblinkhttps://www.termedia.pl/Dental-and-skeletal-changes-after-intra-oral-molar-ndistalization-using-a-Distal-Driver-appliance-na-pilot-study,137,34839,1,1.htmlpl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-SA
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enmolar distalizationpl
dc.subject.enClass II malocclusionpl
dc.subject.enintraoral distalizing appliancepl
dc.subject.pldystalizacja trzonowcówpl
dc.subject.plwada klasy drugiejpl
dc.subject.plwewnątrzustny aparat do dystalizacjipl
dc.subtypeArticlepl
dc.titleDental and skeletal changes after intra-oral molar distalization using a "Distal Driver" appliance : a pilot studypl
dc.title.alternativeZmiany zębowe i szkieletowe po zastosowaniu wewnątrzustnego aparatu do dystalizacji Distal Driver : badanie pilotażowepl
dc.title.journalJournal of Stomatologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T20:48:39Z
dc.abstract.enpl
Introduction. Loss of space in the maxillary arch is a frequent consequence of early loss of deciduous molars indicating distalisation of the mesialised molar tooth. A number of methods using either extra-oral appliances or intra oral appliances of various types have been suggested. While extra-oral appliances exert a high but intermittent force many of the intraoral ones deliver a modest, though constant, force and demands no patient cooperation. Aim of study. To investigate the effect of an intra-oral fixed appliance (Distal Driver) based on a NiTi spring incorporating also a standardised anchorage unit on the position of the maxillary first molar as well as on the facial skeleton and the dentition in general. Material and methods. The experimental group comprised 6 child patients exhibiting a distal molar relationship (Unilateral or Bilateral) of at least ½ premolar unit. The mesialised molars were distalised by means of a “Distal Driver” exerting a force of 150 gm for a period of 3-4 weeks. Anchorage was created by a fixed modified palatal bar cemented on the premolars supporting an acrylic palatal button ad modum Nance. The clinical situation was recorded before and after molar distalisation by means of study casts, cephalograms, panoramic radiographs as well as intra-oral photographs. The distalisation of the molars as well as the effect on anchorage teeth was quantitated on digital models derived from the plaster casts. Evaluation of the observed distal and vertical changes in molar position was performed on the lateral cephalogram. Results. Cast analysis showed a clear distalising effect on the maxillary first molars ranging from 1.25 mm to 6.18 mm as well as mesial movement of the premolar anchorage teeth from 0.46 mm to 5.55mm. The cephalometric analysis revealed a first molar distalisation of 0.9 mm to 5.6 mm though again with a mesial movement of the first premolar varying from 0.5 mm to 3.7 mm. A clear distal tipping of the first and second molars simultaneously with a mesial tipping of the first premolars was also recorded. Conclusion. The Distal Driver constitutes an efficient method of maxillary molar distalisation though is often accompanied by a distal rotation of these teeth and a mesial tipping of the anchorage premolars. Careful monitoring of anchorage loss is necessary if good results are to be achieved.
dc.abstract.plpl
Wstęp. Niedobór miejsca w górnym łuku zębowym będący często konsekwencją przedwczesnej utraty zębów trzonowych mlecznych, wskazuje na konieczność dystalizacji przemieszczonych mezjalnie stałych pierwszych zębów trzonowych. Dostępnych jest wiele metod uwzględniających użycie aparatów zewnątrzustnch bądź różnego typu aparatów wewnątrzustnych. Podczas gdy aparaty zewnątrzustne dostarczają znacznej, lecz przerywanej siły, aparaty wewnątrzustne działają wywołując średnie poziomy sił nawet przy braku współpracy ze strony pacjenta. Cel badania. Celem badania była ocena efektywności wewnątrzustnego stałego aparatu (Distal Driver) opartego na otwartej sprężynce NiTi oraz standardowej jednostce kotwiącej w dystalizacji pierwszych zębów trzonowych szczęki oraz jego wpływu na struktury szkieletowe i zębowe. Materiał i metoda. Grupa badawcza składała się z 6 pacjentów w wieku dziecięcym demonstrujących dystalną relację zębów trzonowych (jednostronnie lub obustronnie) w zakresie przynajmniej ½ jednostki. Mezjalnie przemieszczone zęby trzonowe zdystalizowano aparatem „Distal Driver” wywierając siłę 150g przez okres 3-4 tygodni. Zakotwienie uzyskano stosując przerzut podniebienny cementowany do pierwszych zębów przedtrzonowych oraz wzmocniony guziczkiem podniebiennym na wzór aparatu Nance. Przed leczeniem oraz po zakończeniu dystalizacji wykonano dokumentację w postaci modeli, zdjęć cefalometrycznych, zdjęć pantomograficznych oraz zdjęć fotograficznych wewnątrzustnych. Dystalizacja pierwszych zębów trzonowych oraz zmiany w położeniu zębów jednostki kotwiącej zostały ocenione na modelach cyfrowych otrzymanych na podstawie skanu modeli gipsowych. Pomiaru dystalizacji oraz zmian w pionowym położeniu zębów trzonowych dokonano na zdjęciach cefalometrycznych. Wyniki. Analiza modeli wykazała dystalizację pierwszych zębów trzonowych szczęki w zakresie od 1,25 mm do 6,18 mm oraz mezjalizację zębów przedtrzonowych włączonych do jednostki kotwiącej wielkości od 0,46 mm do 5,55mm. Zgodnie z analizą cefalometryczną uzyskano od 0,9mm do 5,6mm dystalizacji pierwszych zębów trzonowych kosztem od 0.5mm do 3.7mm mezjalizacji zębów przedtrzonowych. Odnotowano także dystalne nachylenie pierwszych i drugich zębów trzonowych z jednoczesnym mezjalnym nachyleniem pierwszych zębów przedtrzonowych. Wnioski. Aparat “Distal Driver” stanowi efektywną metodę dystalizacji pierwszych zębów trzonowych szczęki, jednak jego działaniu często towarzyszą efekty uboczne w postaci dystorotacji tych zębów oraz mezjalnego nachylenia zębów przedtrzonowych jednostki kotwiącej. W celu uzyskania pożądanych rezultatów wskazana jest uważna kontrola utraty zakotwienia.
dc.affiliationpl
Wydział Lekarski : Instytut Stomatologii
dc.cm.date
2020-01-07
dc.cm.id
80452
dc.contributor.authorpl
Urbaniak-Malinowska, Gabriela
dc.contributor.authorpl
Gibas-Stanek, Marta - 357858
dc.contributor.authorpl
Williams, Stephen - 213994
dc.contributor.authorpl
Stós, Wojciech - 133518
dc.contributor.authorpl
Loster, Bartłomiej - 130712
dc.date.accessionpl
2020-09-22
dc.date.accessioned
2020-01-17T09:14:14Z
dc.date.available
2020-01-17T09:14:14Z
dc.date.issuedpl
2016
dc.date.openaccess
0
dc.description.accesstime
po opublikowaniu
dc.description.additionalpl
Tekst równolegle w j. pol i j .ang. Bibliogr. s. 710-711
dc.description.numberpl
6
dc.description.physicalpl
695-711
dc.description.pointspl
12
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
69
dc.identifier.doipl
10.5604/00114553.1230590
dc.identifier.eissnpl
2299-551X
dc.identifier.issnpl
0011-4553
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/139607
dc.identifier.weblinkpl
https://www.termedia.pl/Dental-and-skeletal-changes-after-intra-oral-molar-ndistalization-using-a-Distal-Driver-appliance-na-pilot-study,137,34839,1,1.html
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-SA
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
molar distalization
dc.subject.enpl
Class II malocclusion
dc.subject.enpl
intraoral distalizing appliance
dc.subject.plpl
dystalizacja trzonowców
dc.subject.plpl
wada klasy drugiej
dc.subject.plpl
wewnątrzustny aparat do dystalizacji
dc.subtypepl
Article
dc.titlepl
Dental and skeletal changes after intra-oral molar distalization using a "Distal Driver" appliance : a pilot study
dc.title.alternativepl
Zmiany zębowe i szkieletowe po zastosowaniu wewnątrzustnego aparatu do dystalizacji Distal Driver : badanie pilotażowe
dc.title.journalpl
Journal of Stomatology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
20
Views per month
Views per city
Ashburn
3
Des Moines
2
Dublin
2
Wroclaw
2
Boardman
1
Lappeenranta
1
Neunkirchen
1
Nowe Miasto Lubawskie
1
Ostróda
1
Zembrzyce
1
Downloads
urbaniak-malinowska_et-al_dental_and_skeletal_changes_after_intra-oral_molar_distalization_using_2016.pdf
22
urbaniak-malinowska_et-al_dental_and_skeletal_changes_after_intra-oral_molar_distalization_using_2016.txt
2