Whole-body diffusion-weighted imaging with background body signal suppression in the detection of osseous and extra-osseous metastases

2019
journal article
article
12
dc.abstract.enPurpose: To assess the reproducibility of detection of osseous and extra-osseous metastases in cancer patients using whole-body diffusion-weighted imaging with background body signal suppression (WB-DWIBS). Material and methods: A prospective study was conducted on 39 consecutive patients (21 females, 18 males; mean age 48 years) with metastases, who underwent WB-DWIBS on a 1.5-T MR scanner. Image analysis was performed independently by two blinded observers. Inter-observer agreement was assessed for the detection of osseous (spinal, appendicular) and extra-osseous (hepatic, pulmonary, nodal, and peritoneal) metastases. Results: The overall inter-observer agreement of WB-DWIBS in the detection of osseous and extra-osseous metastases was excellent (k = 0.887, agreement = 94.44%, p = 0.001). There was excellent inter-observer agreement of both observers for the detection of osseous spinal (k = 0.846, agreement = 92.3%), osseous appendicular (k = 0.898, agreement = 94.8 %), hepatic (k = 0.847, agreement = 92.3%), pulmonary (k = 0.938, agreement = 97.4%), nodal metastases (k = 0.856, agreement = 94.9%), and peritoneal metastasis (k = 0.772, agreement = 94.9%). Conclusion: We concluded that WB-DWIBS is reproducible for detection of osseous and extra-osseous metastases in cancer patients.pl
dc.contributor.authorAbdel Razek, Ahmedpl
dc.contributor.authorTawfik, Ahmedpl
dc.contributor.authorAbdel Rahman, Mariampl
dc.contributor.authorTeima, Salehpl
dc.date.accessioned2020-01-08T18:29:13Z
dc.date.available2020-01-08T18:29:13Z
dc.date.issued2019pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e457-e458pl
dc.description.physicale453-e458pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume84pl
dc.identifier.doi10.5114/pjr.2019.90057pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/130197
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enmetastasespl
dc.subject.enwhole-bodypl
dc.subject.enDWIBSpl
dc.subject.endiagnosispl
dc.subject.enstagingpl
dc.subtypeArticlepl
dc.titleWhole-body diffusion-weighted imaging with background body signal suppression in the detection of osseous and extra-osseous metastasespl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Purpose: To assess the reproducibility of detection of osseous and extra-osseous metastases in cancer patients using whole-body diffusion-weighted imaging with background body signal suppression (WB-DWIBS). Material and methods: A prospective study was conducted on 39 consecutive patients (21 females, 18 males; mean age 48 years) with metastases, who underwent WB-DWIBS on a 1.5-T MR scanner. Image analysis was performed independently by two blinded observers. Inter-observer agreement was assessed for the detection of osseous (spinal, appendicular) and extra-osseous (hepatic, pulmonary, nodal, and peritoneal) metastases. Results: The overall inter-observer agreement of WB-DWIBS in the detection of osseous and extra-osseous metastases was excellent (k = 0.887, agreement = 94.44%, p = 0.001). There was excellent inter-observer agreement of both observers for the detection of osseous spinal (k = 0.846, agreement = 92.3%), osseous appendicular (k = 0.898, agreement = 94.8 %), hepatic (k = 0.847, agreement = 92.3%), pulmonary (k = 0.938, agreement = 97.4%), nodal metastases (k = 0.856, agreement = 94.9%), and peritoneal metastasis (k = 0.772, agreement = 94.9%). Conclusion: We concluded that WB-DWIBS is reproducible for detection of osseous and extra-osseous metastases in cancer patients.
dc.contributor.authorpl
Abdel Razek, Ahmed
dc.contributor.authorpl
Tawfik, Ahmed
dc.contributor.authorpl
Abdel Rahman, Mariam
dc.contributor.authorpl
Teima, Saleh
dc.date.accessioned
2020-01-08T18:29:13Z
dc.date.available
2020-01-08T18:29:13Z
dc.date.issuedpl
2019
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e457-e458
dc.description.physicalpl
e453-e458
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
84
dc.identifier.doipl
10.5114/pjr.2019.90057
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/130197
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
metastases
dc.subject.enpl
whole-body
dc.subject.enpl
DWIBS
dc.subject.enpl
diagnosis
dc.subject.enpl
staging
dc.subtypepl
Article
dc.titlepl
Whole-body diffusion-weighted imaging with background body signal suppression in the detection of osseous and extra-osseous metastases
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
29
Views per month
Views per city
Hong Kong
7
Des Moines
5
Dublin
4
Ashburn
2
Wroclaw
2
Downloads
abdel-razek_tawfik_abdel-rahman_teima_whole-body_diffusion-weighted_imaging_2019.odt
15
abdel-razek_tawfik_abdel-rahman_teima_whole-body_diffusion-weighted_imaging_2019.pdf
10