Simple view
Full metadata view
Authors
Statistics
Perianal fistula imaging : a comparison between two-channel superficial Flex coil and eight-channel body coil
magnetic resonance imaging
coil
perianal fistulae
Bibliogr. s. e434-e435
Purpose: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained with a phased-array body coil in PFI. Material and methods: Thirty-one fistulas of 29 patients were prospectively evaluated with magnetic resonance imaging. A phased-array body coil was used in all patients as in routine practice, and sequences with Flex-M coil were also obtained. Afterwards, images were evaluated by two experienced radiologists who were blinded to the patients, coil and also to each other. The site of internal and external openings, and presence or absence of abscess and secondary tracts were recorded. Results: The conspicuity of images was better with the Flex-M coil. Both radiologists saw more internal openings with the Flex-M coil. Cohen's κ value was 0.100 (p = 0.201) for Reader 1 and 0.110 (p = 0.361) for Reader 2 between these two coils. Additionally, numerically more internal/external openings and secondary tracts were seen by both readers. Interobserver variability was not statistically significant, and Cohen's κ values signifyied good concordance between readers. Conclusions: In our study we showed that multichannel superficial phased-array coils improved imaging quality in PFI. We think that Flex-M coil can easily be used in routine clinical practice to gather better images of perianal fistulas.
cris.lastimport.wos | 2024-04-09T19:47:35Z | |
dc.abstract.en | Purpose: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained with a phased-array body coil in PFI. Material and methods: Thirty-one fistulas of 29 patients were prospectively evaluated with magnetic resonance imaging. A phased-array body coil was used in all patients as in routine practice, and sequences with Flex-M coil were also obtained. Afterwards, images were evaluated by two experienced radiologists who were blinded to the patients, coil and also to each other. The site of internal and external openings, and presence or absence of abscess and secondary tracts were recorded. Results: The conspicuity of images was better with the Flex-M coil. Both radiologists saw more internal openings with the Flex-M coil. Cohen's κ value was 0.100 (p = 0.201) for Reader 1 and 0.110 (p = 0.361) for Reader 2 between these two coils. Additionally, numerically more internal/external openings and secondary tracts were seen by both readers. Interobserver variability was not statistically significant, and Cohen's κ values signifyied good concordance between readers. Conclusions: In our study we showed that multichannel superficial phased-array coils improved imaging quality in PFI. We think that Flex-M coil can easily be used in routine clinical practice to gather better images of perianal fistulas. | pl |
dc.contributor.author | Akyel, Nazlı Gülsüm | pl |
dc.contributor.author | Akın, Kayıhan | pl |
dc.contributor.author | Kösehan, Dilek | pl |
dc.contributor.author | Köktener, Aslı | pl |
dc.date.accessioned | 2020-01-08T17:57:35Z | |
dc.date.available | 2020-01-08T17:57:35Z | |
dc.date.issued | 2019 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. e434-e435 | pl |
dc.description.physical | e430-e435 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 84 | pl |
dc.identifier.doi | 10.5114/pjr.2019.89906 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.project | ROD UJ / OP | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/130194 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | magnetic resonance imaging | pl |
dc.subject.en | coil | pl |
dc.subject.en | perianal fistulae | pl |
dc.subtype | Article | pl |
dc.title | Perianal fistula imaging : a comparison between two-channel superficial Flex coil and eight-channel body coil | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
28
Views per month
Views per city
Downloads
Open Access