Perianal fistula imaging : a comparison between two-channel superficial Flex coil and eight-channel body coil

2019
journal article
article
1
cris.lastimport.wos2024-04-09T19:47:35Z
dc.abstract.enPurpose: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained with a phased-array body coil in PFI. Material and methods: Thirty-one fistulas of 29 patients were prospectively evaluated with magnetic resonance imaging. A phased-array body coil was used in all patients as in routine practice, and sequences with Flex-M coil were also obtained. Afterwards, images were evaluated by two experienced radiologists who were blinded to the patients, coil and also to each other. The site of internal and external openings, and presence or absence of abscess and secondary tracts were recorded. Results: The conspicuity of images was better with the Flex-M coil. Both radiologists saw more internal openings with the Flex-M coil. Cohen's κ value was 0.100 (p = 0.201) for Reader 1 and 0.110 (p = 0.361) for Reader 2 between these two coils. Additionally, numerically more internal/external openings and secondary tracts were seen by both readers. Interobserver variability was not statistically significant, and Cohen's κ values signifyied good concordance between readers. Conclusions: In our study we showed that multichannel superficial phased-array coils improved imaging quality in PFI. We think that Flex-M coil can easily be used in routine clinical practice to gather better images of perianal fistulas.pl
dc.contributor.authorAkyel, Nazlı Gülsümpl
dc.contributor.authorAkın, Kayıhanpl
dc.contributor.authorKösehan, Dilekpl
dc.contributor.authorKöktener, Aslıpl
dc.date.accessioned2020-01-08T17:57:35Z
dc.date.available2020-01-08T17:57:35Z
dc.date.issued2019pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e434-e435pl
dc.description.physicale430-e435pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume84pl
dc.identifier.doi10.5114/pjr.2019.89906pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/130194
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enmagnetic resonance imagingpl
dc.subject.encoilpl
dc.subject.enperianal fistulaepl
dc.subtypeArticlepl
dc.titlePerianal fistula imaging : a comparison between two-channel superficial Flex coil and eight-channel body coilpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T19:47:35Z
dc.abstract.enpl
Purpose: Perianal fistula is an important health problem with devastating morbidity. For diagnosis and prevention of recurrence, perianal fistula imaging (PFI) is crucial. The aim of this study was to investigate if a Flex-M superficial coil images would provide more information than images obtained with a phased-array body coil in PFI. Material and methods: Thirty-one fistulas of 29 patients were prospectively evaluated with magnetic resonance imaging. A phased-array body coil was used in all patients as in routine practice, and sequences with Flex-M coil were also obtained. Afterwards, images were evaluated by two experienced radiologists who were blinded to the patients, coil and also to each other. The site of internal and external openings, and presence or absence of abscess and secondary tracts were recorded. Results: The conspicuity of images was better with the Flex-M coil. Both radiologists saw more internal openings with the Flex-M coil. Cohen's κ value was 0.100 (p = 0.201) for Reader 1 and 0.110 (p = 0.361) for Reader 2 between these two coils. Additionally, numerically more internal/external openings and secondary tracts were seen by both readers. Interobserver variability was not statistically significant, and Cohen's κ values signifyied good concordance between readers. Conclusions: In our study we showed that multichannel superficial phased-array coils improved imaging quality in PFI. We think that Flex-M coil can easily be used in routine clinical practice to gather better images of perianal fistulas.
dc.contributor.authorpl
Akyel, Nazlı Gülsüm
dc.contributor.authorpl
Akın, Kayıhan
dc.contributor.authorpl
Kösehan, Dilek
dc.contributor.authorpl
Köktener, Aslı
dc.date.accessioned
2020-01-08T17:57:35Z
dc.date.available
2020-01-08T17:57:35Z
dc.date.issuedpl
2019
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. e434-e435
dc.description.physicalpl
e430-e435
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
84
dc.identifier.doipl
10.5114/pjr.2019.89906
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/130194
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
magnetic resonance imaging
dc.subject.enpl
coil
dc.subject.enpl
perianal fistulae
dc.subtypepl
Article
dc.titlepl
Perianal fistula imaging : a comparison between two-channel superficial Flex coil and eight-channel body coil
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
28
Views per month
Views per city
Hong Kong
6
Des Moines
5
Ashburn
4
Dublin
4
Wroclaw
2
Lublin
1
Downloads
akyel_akin_kosehan_koktener_perianal_fistula_imaging_a_comparison_2019.odt
125
akyel_akin_kosehan_koktener_perianal_fistula_imaging_a_comparison_2019.pdf
7