Opracowanie i walidacja metody oznaczania wybranych leków stosowanych w leczeniu nadciśnienia tętniczego z zastosowaniem techniki LC/MS/MS

master
dc.abstract.enThe aim of this study was to develop and validate simultaneous quantitative and qualitative determination of fifteen drugs in human plasama used to treat hypertension (amiodarone, bisoprolol, digoxin, eplerenone, furosemide, ivabradine, carvedilol, lisinopril, metoprolol, nebivolol, perindopril, ramipril, spironolactone, torasemide, zofenopril). At the beginning plasma samples were precipitated or extracted. Afterwards analysis was performed using high performance liquid chromatography with tandem mass spectroscopy combined with electrospray ionization (LC-ESI/MS/MS). The developed method corresponds to the validation criteria of bioanalytical methods made by FDA and EMA. Performed method was characterized by high sensitivity, enabling the determination of selected drugs in human plasma. The precision of the method for the tested compounds was lower than 15 % and the accuracy was within 85-115 %. For all drugs the linearity in wide range of concentration was obtained and the coefficient of correlation was higher than 0.99. The developed method was used to determine the concentration of drugs tested in the context of therapeutic drug monitoring. In a plasma collected from six patients diagnosed with resistant hypertension were identified and determined concentration of the three drugs such as amiodarone, furosemide and ramipril.pl
dc.abstract.plCelem pracy było opracowanie i walidacja metody jednoczesnego oznaczania wybranych leków stosowanych w leczeniu nadciśnienia tętniczego (amiodaron, bisoprolol, digoksyna, eplerenon, furosemid, iwabradyna, karwedilol, lisinopril, metoprolol, nebiwolol, perindopril, ramipril, spironolakton, torasemid, zofenopril) w osoczu ludzkim. Oznaczenia prowadzono z zastosowaniem wysokosprawnej chromatografii cieczowej sprzężonej z tandemową spektrometrią mas z jonizacją typu elektrorozpylania (LC-ESI/MS/MS) po uprzednim przygotowaniu próbek osocza przez strącenie lub ekstrakcję. Opracowana metoda spełnia kryteria walidacji opracowane przez FDA i EMA dla metod bioanalitycznych. Opracowana metoda cechowała się wysoką czułością, umożliwiając oznaczenia wybranych leków w osoczu ludzkim. Precyzja metody dla badanych związków była niższa od 15%, a dokładność mieściła się w granicach 85 115%. Dla badanych leków uzyskano liniowość w szerokim zakresie stężeń, a współczynnik korelacji był wyższy od 0.99.Opracowaną metodę zastosowano do oznaczenia stężenia badanych leków w ramach terapii pod kontrolą stężenia leku we krwi. W osoczu pobranym od sześciu chorych, u których zdiagnozowano oporne nadciśnienie tętnicze zidentyfikowano oraz oznaczono stężenie trzech leków, takich jak amiodaron, furosemid i ramipril.pl
dc.affiliationWydział Farmaceutycznypl
dc.areaobszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznejpl
dc.contributor.advisorWalczak, Mariapl
dc.contributor.authorCiupka, Magdalenapl
dc.contributor.departmentbycodeUJK/WFOAM2pl
dc.contributor.reviewerBystrowska, Beata - 128945 pl
dc.contributor.reviewerWalczak, Mariapl
dc.date.accessioned2020-07-27T01:52:28Z
dc.date.available2020-07-27T01:52:28Z
dc.date.submitted2016-09-12pl
dc.fieldofstudyfarmacjapl
dc.identifier.apddiploma-109194-149200pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/215270
dc.languagepolpl
dc.subject.enhypertension, validation, LC/MS/MS, therapeutic drug monitoringpl
dc.subject.plnadciśnienie tętnicze, walidacja, LC/MS/MS, terapia monitorowana stężeniem leku we krwipl
dc.titleOpracowanie i walidacja metody oznaczania wybranych leków stosowanych w leczeniu nadciśnienia tętniczego z zastosowaniem techniki LC/MS/MSpl
dc.title.alternativeDevelopment and validation of method for determination of selected drugs used to treat arterial hypertension using LC/MS/MS.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The aim of this study was to develop and validate simultaneous quantitative and qualitative determination of fifteen drugs in human plasama used to treat hypertension (amiodarone, bisoprolol, digoxin, eplerenone, furosemide, ivabradine, carvedilol, lisinopril, metoprolol, nebivolol, perindopril, ramipril, spironolactone, torasemide, zofenopril). At the beginning plasma samples were precipitated or extracted. Afterwards analysis was performed using high performance liquid chromatography with tandem mass spectroscopy combined with electrospray ionization (LC-ESI/MS/MS). The developed method corresponds to the validation criteria of bioanalytical methods made by FDA and EMA. Performed method was characterized by high sensitivity, enabling the determination of selected drugs in human plasma. The precision of the method for the tested compounds was lower than 15 % and the accuracy was within 85-115 %. For all drugs the linearity in wide range of concentration was obtained and the coefficient of correlation was higher than 0.99. The developed method was used to determine the concentration of drugs tested in the context of therapeutic drug monitoring. In a plasma collected from six patients diagnosed with resistant hypertension were identified and determined concentration of the three drugs such as amiodarone, furosemide and ramipril.
dc.abstract.plpl
Celem pracy było opracowanie i walidacja metody jednoczesnego oznaczania wybranych leków stosowanych w leczeniu nadciśnienia tętniczego (amiodaron, bisoprolol, digoksyna, eplerenon, furosemid, iwabradyna, karwedilol, lisinopril, metoprolol, nebiwolol, perindopril, ramipril, spironolakton, torasemid, zofenopril) w osoczu ludzkim. Oznaczenia prowadzono z zastosowaniem wysokosprawnej chromatografii cieczowej sprzężonej z tandemową spektrometrią mas z jonizacją typu elektrorozpylania (LC-ESI/MS/MS) po uprzednim przygotowaniu próbek osocza przez strącenie lub ekstrakcję. Opracowana metoda spełnia kryteria walidacji opracowane przez FDA i EMA dla metod bioanalitycznych. Opracowana metoda cechowała się wysoką czułością, umożliwiając oznaczenia wybranych leków w osoczu ludzkim. Precyzja metody dla badanych związków była niższa od 15%, a dokładność mieściła się w granicach 85 115%. Dla badanych leków uzyskano liniowość w szerokim zakresie stężeń, a współczynnik korelacji był wyższy od 0.99.Opracowaną metodę zastosowano do oznaczenia stężenia badanych leków w ramach terapii pod kontrolą stężenia leku we krwi. W osoczu pobranym od sześciu chorych, u których zdiagnozowano oporne nadciśnienie tętnicze zidentyfikowano oraz oznaczono stężenie trzech leków, takich jak amiodaron, furosemid i ramipril.
dc.affiliationpl
Wydział Farmaceutyczny
dc.areapl
obszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznej
dc.contributor.advisorpl
Walczak, Maria
dc.contributor.authorpl
Ciupka, Magdalena
dc.contributor.departmentbycodepl
UJK/WFOAM2
dc.contributor.reviewerpl
Bystrowska, Beata - 128945
dc.contributor.reviewerpl
Walczak, Maria
dc.date.accessioned
2020-07-27T01:52:28Z
dc.date.available
2020-07-27T01:52:28Z
dc.date.submittedpl
2016-09-12
dc.fieldofstudypl
farmacja
dc.identifier.apdpl
diploma-109194-149200
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/215270
dc.languagepl
pol
dc.subject.enpl
hypertension, validation, LC/MS/MS, therapeutic drug monitoring
dc.subject.plpl
nadciśnienie tętnicze, walidacja, LC/MS/MS, terapia monitorowana stężeniem leku we krwi
dc.titlepl
Opracowanie i walidacja metody oznaczania wybranych leków stosowanych w leczeniu nadciśnienia tętniczego z zastosowaniem techniki LC/MS/MS
dc.title.alternativepl
Development and validation of method for determination of selected drugs used to treat arterial hypertension using LC/MS/MS.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
30
Views per month
Views per city
Nowy Wisnicz
5
Warsaw
5
Dublin
3
Wroclaw
3
Lodz
2
Tarnobrzeg
2
Brno
1
Bydgoszcz
1
Krakow
1
Otwock
1

No access

No Thumbnail Available