Optymalizacja parametrów akwizycji oraz rekonstrukcji opracowanego fantomu do testowania dopasowania cięć tomograficznych uzyskanych technikami SPECT i CT

master
dc.abstract.enQuality control tests are designed to verify and determine the correctness of the medical equipment being tested. They are legally regulated in the Journal of Laws of the Republic of Poland of 5 May 2017. Pos. 884 being the Notice of Minister of Health of 3 April 2017 on the announcement of the uniform text of the Regulation of the Minister of Health on the conditions of safe use of ionizing radiation for all types of medical exposure.Due to the lack of guidelines for the selection of acquisition and reconstruction parameters for quality assurance tests, the problem of obtaining the highest quality images at the shortest time of acquisition is encountered. Therefore, the purpose of this paper was to determine the optimal configuration of phantom acquisition and reconstruction parameters for the phantom obtained for SPECT / CT hybrid devices as a final criterion to minimize the time needed to perform such a test.For this purpose, a series of measurements was performed for the CT scan fitting of the SPECT and CT techniques using a phantom designed to change one of the acquisition or reconstruction parameters into three groups. The study was conducted on the Mediso AnyScan SC hybrid tomography located in the Nuclear Medicine Laboratory of the Oncology Center of the Institute Maria Skłodowska-Curie Branch in Cracow. All tests were performed using Jaszczak Deluxe Phantom cylinder. The images received were quantitatively analyzed taking into account variables such as projection number, single projection acquisition time, and reconstruction subsets, as a prerequisite for maintaining high image quality relative to the reference image, and reducing the time needed to complete the projection. A set of acquisition parameters for Mediso AnyScan SC hybrid tomography has been demonstrated.pl
dc.abstract.plTesty kontroli jakości mają za zadanie sprawdzenie i określenie poprawności działania badanej aparatury medycznej, są one uregulowane prawnie w Dzienniku Ustaw Rzeczypospolitej Polskiej z dnia 5 maja 2017 r. Poz. 884 będącej Obwieszczeniem Ministra Zdrowia z dnia 3 kwietnia 2017 r. w sprawie ogłoszenia jednolitego tekstu rozporządzenia Ministra Zdrowia w sprawie warunków bezpiecznego stosowania promieniowania jonizującego dla wszystkich rodzajów ekspozycji medycznej. Ze względu na brak wytycznych dotyczących doboru parametrów akwizycji i rekonstrukcji dla testów kontroli jakości napotykany jest problem związany z uzyskiwaniem obrazów o jak najwyższej jakości przy skróceniu czasu ich uzyskiwania. W związku z tym celem niniejszej pracy było określenie optymalnej konfiguracji parametrów akwizycji oraz rekonstrukcji dla fantomu przeznaczonego do testów dopasowania cięć tomograficznych uzyskanych dla urządzeń hybrydowych SPECT/CT, biorąc jako ostateczne kryterium minimalizację czasu potrzebnego na przeprowadzenie takiego testu.W tym celu, dla testu dopasowania cięć tomograficznych uzyskiwanymi technikami SPECT i CT z użyciem zaprojektowanego fantomu przeprowadzono serię pomiarów zmieniając jeden z parametrów akwizycji lub rekonstrukcji tworząc trzy grupy. Badania przeprowadzano na tomografie hybrydowym Mediso AnyScan SC znajdującym się w Pracowni Medycyny Nuklearnej Centrum Onkologii Instytutu im. Marii Skłodowskiej-Curie Oddział w Krakowie. Wszystkie testy wykonano z wykorzystaniem cylindra fantomu Jaszczaka Deluxe firmy Mediso. Otrzymane obrazy poddano analizie ilościowej uwzględniając zmienne dotyczące: liczby projekcji, czasu akwizycji pojedynczej projekcji czy liczby podzbiorów w rekonstrukcji, biorąc jako warunek utrzymanie wysokiej jakości obrazu względem obrazu referencyjnego oraz skrócenie czasu potrzebnego na jego wykonanie. Wykazano zestaw parametrów akwizycji dla tomografu hybrydowego Mediso AnyScan SC.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanejpl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorStanek, Jan - 100112 pl
dc.contributor.advisorWaligórski, Michałpl
dc.contributor.authorJabłońska, Patrycjapl
dc.contributor.departmentbycodeUJK/WFAISpl
dc.contributor.reviewerStanek, Jan - 100112 pl
dc.contributor.reviewerWaligórski, Michałpl
dc.contributor.reviewerStępień, Ewa - 161583 pl
dc.date.accessioned2020-07-27T11:38:21Z
dc.date.available2020-07-27T11:38:21Z
dc.date.submitted2017-10-04pl
dc.fieldofstudyfizyka medycznapl
dc.identifier.apddiploma-119104-167742pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/224118
dc.languagepolpl
dc.source.integratorfalse
dc.subject.enSPECT, CT, quality control, Jaszczak phantom, nuclear medicinepl
dc.subject.plSPECT, CT, testy kontroli jakości, fantom Jaszczaka, medycyna nuklearnapl
dc.titleOptymalizacja parametrów akwizycji oraz rekonstrukcji opracowanego fantomu do testowania dopasowania cięć tomograficznych uzyskanych technikami SPECT i CTpl
dc.title.alternativeOptimization of acquisition and reconstruction parameters of developed phantom for the test of matching between SPECT and CT.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
Quality control tests are designed to verify and determine the correctness of the medical equipment being tested. They are legally regulated in the Journal of Laws of the Republic of Poland of 5 May 2017. Pos. 884 being the Notice of Minister of Health of 3 April 2017 on the announcement of the uniform text of the Regulation of the Minister of Health on the conditions of safe use of ionizing radiation for all types of medical exposure.Due to the lack of guidelines for the selection of acquisition and reconstruction parameters for quality assurance tests, the problem of obtaining the highest quality images at the shortest time of acquisition is encountered. Therefore, the purpose of this paper was to determine the optimal configuration of phantom acquisition and reconstruction parameters for the phantom obtained for SPECT / CT hybrid devices as a final criterion to minimize the time needed to perform such a test.For this purpose, a series of measurements was performed for the CT scan fitting of the SPECT and CT techniques using a phantom designed to change one of the acquisition or reconstruction parameters into three groups. The study was conducted on the Mediso AnyScan SC hybrid tomography located in the Nuclear Medicine Laboratory of the Oncology Center of the Institute Maria Skłodowska-Curie Branch in Cracow. All tests were performed using Jaszczak Deluxe Phantom cylinder. The images received were quantitatively analyzed taking into account variables such as projection number, single projection acquisition time, and reconstruction subsets, as a prerequisite for maintaining high image quality relative to the reference image, and reducing the time needed to complete the projection. A set of acquisition parameters for Mediso AnyScan SC hybrid tomography has been demonstrated.
dc.abstract.plpl
Testy kontroli jakości mają za zadanie sprawdzenie i określenie poprawności działania badanej aparatury medycznej, są one uregulowane prawnie w Dzienniku Ustaw Rzeczypospolitej Polskiej z dnia 5 maja 2017 r. Poz. 884 będącej Obwieszczeniem Ministra Zdrowia z dnia 3 kwietnia 2017 r. w sprawie ogłoszenia jednolitego tekstu rozporządzenia Ministra Zdrowia w sprawie warunków bezpiecznego stosowania promieniowania jonizującego dla wszystkich rodzajów ekspozycji medycznej. Ze względu na brak wytycznych dotyczących doboru parametrów akwizycji i rekonstrukcji dla testów kontroli jakości napotykany jest problem związany z uzyskiwaniem obrazów o jak najwyższej jakości przy skróceniu czasu ich uzyskiwania. W związku z tym celem niniejszej pracy było określenie optymalnej konfiguracji parametrów akwizycji oraz rekonstrukcji dla fantomu przeznaczonego do testów dopasowania cięć tomograficznych uzyskanych dla urządzeń hybrydowych SPECT/CT, biorąc jako ostateczne kryterium minimalizację czasu potrzebnego na przeprowadzenie takiego testu.W tym celu, dla testu dopasowania cięć tomograficznych uzyskiwanymi technikami SPECT i CT z użyciem zaprojektowanego fantomu przeprowadzono serię pomiarów zmieniając jeden z parametrów akwizycji lub rekonstrukcji tworząc trzy grupy. Badania przeprowadzano na tomografie hybrydowym Mediso AnyScan SC znajdującym się w Pracowni Medycyny Nuklearnej Centrum Onkologii Instytutu im. Marii Skłodowskiej-Curie Oddział w Krakowie. Wszystkie testy wykonano z wykorzystaniem cylindra fantomu Jaszczaka Deluxe firmy Mediso. Otrzymane obrazy poddano analizie ilościowej uwzględniając zmienne dotyczące: liczby projekcji, czasu akwizycji pojedynczej projekcji czy liczby podzbiorów w rekonstrukcji, biorąc jako warunek utrzymanie wysokiej jakości obrazu względem obrazu referencyjnego oraz skrócenie czasu potrzebnego na jego wykonanie. Wykazano zestaw parametrów akwizycji dla tomografu hybrydowego Mediso AnyScan SC.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Stanek, Jan - 100112
dc.contributor.advisorpl
Waligórski, Michał
dc.contributor.authorpl
Jabłońska, Patrycja
dc.contributor.departmentbycodepl
UJK/WFAIS
dc.contributor.reviewerpl
Stanek, Jan - 100112
dc.contributor.reviewerpl
Waligórski, Michał
dc.contributor.reviewerpl
Stępień, Ewa - 161583
dc.date.accessioned
2020-07-27T11:38:21Z
dc.date.available
2020-07-27T11:38:21Z
dc.date.submittedpl
2017-10-04
dc.fieldofstudypl
fizyka medyczna
dc.identifier.apdpl
diploma-119104-167742
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/224118
dc.languagepl
pol
dc.source.integrator
false
dc.subject.enpl
SPECT, CT, quality control, Jaszczak phantom, nuclear medicine
dc.subject.plpl
SPECT, CT, testy kontroli jakości, fantom Jaszczaka, medycyna nuklearna
dc.titlepl
Optymalizacja parametrów akwizycji oraz rekonstrukcji opracowanego fantomu do testowania dopasowania cięć tomograficznych uzyskanych technikami SPECT i CT
dc.title.alternativepl
Optimization of acquisition and reconstruction parameters of developed phantom for the test of matching between SPECT and CT.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
24
Views per month
Views per city
Krakow
3
Warsaw
3
Chorowice
2
Dublin
2
Szczecin
2
Wroclaw
2
Gdansk
1
Piekary Śląskie
1
Riga
1
Tarnów
1

No access

No Thumbnail Available