Analysis of fungal air pollution using different samplers

2011
journal article
article
dc.abstract.enThe aim of this study was the analysis of fungal air pollution in different rooms using different the air samplers. Air for mycological studies was collected from various hospital rooms. To monitor fungal air pollution were used samplers: SAS SUPER 100 (pbi-international), MAS 100 (Merck) and AIR IDEAL (BioMerieux). We found differences in CFU/L values in depending on hospital room and the air sampler type. The CFU/L values of air samples taken by the AIR IDEAL ranged from 350 to 850 and (724.2 ± 159.9), and the CFU/L values of air samples taken by the sampler SAS SUPER 100 ranged from 160 to 800 (455.3 ± 250.73). The CFU/L values of air samples taken by the MAS 100 sampler varied from 50 to 1340 (302.5±56.6) From the air samples of both samplers was incubated 6 genera/species of fungi. Candia albicans fungi species and genus Penicillium species were most frequently isolated from SAS Super 100 sampler, and Penicillium species from the AIR IDEAL sampler. From the air samples of MAS 100 was isolated 11 types/species of fungi and in air samples of SAS Super 100 was isolated 7 types/species. Significant differences of CFU/L values in the tested rooms were found in depending on the used sampler. Mycological analysis of the obtained cultures from air samples suggests that there is not same isolation of fungi using the different samplers.pl
dc.affiliationWydział Nauk o Zdrowiu : Instytut Pielęgniarstwa i Położnictwapl
dc.contributor.authorŁukaszuk, C.pl
dc.contributor.authorKrajewska-Kułak, E.pl
dc.contributor.authorGniadek, Agnieszka - 129519 pl
dc.contributor.authorChadzopulu, A.pl
dc.contributor.authorTheodosopoulou, E.pl
dc.contributor.authorBousmoukilia, S.pl
dc.contributor.authorTerovitou, Ch.pl
dc.contributor.authorAmanatidou, A.pl
dc.contributor.authorDanilidis, D.pl
dc.contributor.authorAdraniotis, J.pl
dc.date.accession2020-05-26pl
dc.date.accessioned2020-05-26T08:17:13Z
dc.date.available2020-05-26T08:17:13Z
dc.date.issued2011pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 40-42pl
dc.description.number1pl
dc.description.physical34-42pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume1pl
dc.identifier.eissn2083-6260pl
dc.identifier.issn2083-1617pl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/156570
dc.identifier.weblinkhttps://www.umb.edu.pl/photo/pliki/progress-file/phs/phs_2011_1/34-42_lukaszuk.pdfpl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-SA
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enfungipl
dc.subject.enairpl
dc.subject.enAIR IDEALpl
dc.subject.enSAS SUPER 100pl
dc.subtypeArticlepl
dc.titleAnalysis of fungal air pollution using different samplerspl
dc.title.journalProgress in Health Sciencespl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
The aim of this study was the analysis of fungal air pollution in different rooms using different the air samplers. Air for mycological studies was collected from various hospital rooms. To monitor fungal air pollution were used samplers: SAS SUPER 100 (pbi-international), MAS 100 (Merck) and AIR IDEAL (BioMerieux). We found differences in CFU/L values in depending on hospital room and the air sampler type. The CFU/L values of air samples taken by the AIR IDEAL ranged from 350 to 850 and (724.2 ± 159.9), and the CFU/L values of air samples taken by the sampler SAS SUPER 100 ranged from 160 to 800 (455.3 ± 250.73). The CFU/L values of air samples taken by the MAS 100 sampler varied from 50 to 1340 (302.5±56.6) From the air samples of both samplers was incubated 6 genera/species of fungi. Candia albicans fungi species and genus Penicillium species were most frequently isolated from SAS Super 100 sampler, and Penicillium species from the AIR IDEAL sampler. From the air samples of MAS 100 was isolated 11 types/species of fungi and in air samples of SAS Super 100 was isolated 7 types/species. Significant differences of CFU/L values in the tested rooms were found in depending on the used sampler. Mycological analysis of the obtained cultures from air samples suggests that there is not same isolation of fungi using the different samplers.
dc.affiliationpl
Wydział Nauk o Zdrowiu : Instytut Pielęgniarstwa i Położnictwa
dc.contributor.authorpl
Łukaszuk, C.
dc.contributor.authorpl
Krajewska-Kułak, E.
dc.contributor.authorpl
Gniadek, Agnieszka - 129519
dc.contributor.authorpl
Chadzopulu, A.
dc.contributor.authorpl
Theodosopoulou, E.
dc.contributor.authorpl
Bousmoukilia, S.
dc.contributor.authorpl
Terovitou, Ch.
dc.contributor.authorpl
Amanatidou, A.
dc.contributor.authorpl
Danilidis, D.
dc.contributor.authorpl
Adraniotis, J.
dc.date.accessionpl
2020-05-26
dc.date.accessioned
2020-05-26T08:17:13Z
dc.date.available
2020-05-26T08:17:13Z
dc.date.issuedpl
2011
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 40-42
dc.description.numberpl
1
dc.description.physicalpl
34-42
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
1
dc.identifier.eissnpl
2083-6260
dc.identifier.issnpl
2083-1617
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/156570
dc.identifier.weblinkpl
https://www.umb.edu.pl/photo/pliki/progress-file/phs/phs_2011_1/34-42_lukaszuk.pdf
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-SA
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
fungi
dc.subject.enpl
air
dc.subject.enpl
AIR IDEAL
dc.subject.enpl
SAS SUPER 100
dc.subtypepl
Article
dc.titlepl
Analysis of fungal air pollution using different samplers
dc.title.journalpl
Progress in Health Sciences
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
28
Views per month
Views per city
Kozlu
3
Chandler
2
Wroclaw
2
Zonguldak
2
Bandar Seri Begawan
1
Coventry
1
Cuautitlán Izcalli
1
Dublin
1
Guangzhou
1
Helsinki
1
Downloads
gniadek_et-al_analysis_of_fungal_air_pollution_2011.pdf
63
gniadek_et-al_analysis_of_fungal_air_pollution_2011.odt
19