Albumina wołowa jako składnik kompozytu elektrodowego bioczujnika elektrochemicznego do oznaczania peptydu C

licenciate
dc.abstract.enThe aim of the study was to find the appropriate concentration of bovine serum albumin (BSA) used to modify the surface of an electrochemical biosensor in C-peptide assays. The following BSA concentrations were tested: 0.25%, 0.5%, 1.0%, 2.0%. BSA blocks non-specific binding sites of antigen with antibody. In the conducted studies, a screen-printed electrode was used as an electrochemical biosensor. It consists of a working, auxiliary and reference electrode. Two techniques were used in the conducted studies: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Using cyclic voltammetry, voltammograms were recorded, and calibration dependencies were plotted on their basis. Sensitivity and coefficient of determination (linearity) for all tested BSA concentrations were read from the graphs. The EIS technique was used to determine the values of charge transfer resistance, differential capacitance of the electric double layer, and electrochemically active surface for the tested BSA concentrations. Using these two techniques and their development, it was shown that the most optimal BSA concentration in C-peptide assays is 0.5%.pl
dc.abstract.plCelem badanej pracy było znalezienie odpowiedniego stężenia surowiczej albuminy wołowej (BSA) wykorzystywanej do modyfikacji powierzchni bioczujnika elektrochemicznego w oznaczeniach peptydu C. Badano stężenia BSA: 0,25%, 0,5%, 1,0%, 2,0%. BSA blokuje niespecyficzne miejsca wiązania antygenu z przeciwciałem. W przeprowadzonych badaniach jako bioczujnika elektrochemicznego użyto elektrody sitodrukowanej. Składa się ona z elektrody pracującej, pomocniczej i odniesienia. W przeprowadzonych badaniach wykorzystano dwie techniki: woltamperometrię cykliczną (CV) i elektrochemiczną spektroskopię impedancyjną (EIS). Przy użyciu woltamperometrii cyklicznej zarejestrowano woltamperogramy, a na ich podstawie wykreślono zależności kalibracyjne. Z wykonanych wykresów odczytano czułość oraz współczynnik determinacji (liniowość) dla wszystkich badanych stężeń BSA. Za pomocą techniki EIS wyznaczono wartości rezystancji przeniesienia ładunku, pojemości różniczkowej podwójnej warstwy elektrycznej oraz powierzchni aktywnej elektrochemicznie dla badanych stężeń BSA. Przy użyciu tych dwóch technik i ich opracowaniu wykazano, że najbardziej optymalne stężenie BSA w oznaczeniach peptydu C jest równe 0,5%.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorKnihnicki, Paweł - 126218 pl
dc.contributor.authorStańczyk, Diana - USOS302876 pl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerWieczorek, Marcin - 160176 pl
dc.contributor.reviewerKnihnicki, Paweł - 126218 pl
dc.date.accessioned2024-07-04T22:58:53Z
dc.date.available2024-07-04T22:58:53Z
dc.date.submitted2024-07-03pl
dc.fieldofstudychemia medycznapl
dc.identifier.apddiploma-173113-302876pl
dc.identifier.urihttps://ruj.uj.edu.pl/handle/item/369501
dc.languagepolpl
dc.subject.enbovine serum albumin (BSA), C-peptide, electrochemical biosensor, screen-printed electrode (SPE), antibody, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS)pl
dc.subject.plsurowicza albumina wołowa (BSA), peptyd C, bioczujnik elektrochemiczny, elektroda sitodrukowana (SPE), przeciwciało, woltamperometria cykliczna (CV), elektrochemiczna spektroskopia impedancyjna (EIS)pl
dc.titleAlbumina wołowa jako składnik kompozytu elektrodowego bioczujnika elektrochemicznego do oznaczania peptydu Cpl
dc.title.alternativeBovine albumin as a component of the electrode composite for an electrochemical biosensor for C-peptide determinationpl
dc.typelicenciatepl
dspace.entity.typePublication
dc.abstract.enpl
The aim of the study was to find the appropriate concentration of bovine serum albumin (BSA) used to modify the surface of an electrochemical biosensor in C-peptide assays. The following BSA concentrations were tested: 0.25%, 0.5%, 1.0%, 2.0%. BSA blocks non-specific binding sites of antigen with antibody. In the conducted studies, a screen-printed electrode was used as an electrochemical biosensor. It consists of a working, auxiliary and reference electrode. Two techniques were used in the conducted studies: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Using cyclic voltammetry, voltammograms were recorded, and calibration dependencies were plotted on their basis. Sensitivity and coefficient of determination (linearity) for all tested BSA concentrations were read from the graphs. The EIS technique was used to determine the values of charge transfer resistance, differential capacitance of the electric double layer, and electrochemically active surface for the tested BSA concentrations. Using these two techniques and their development, it was shown that the most optimal BSA concentration in C-peptide assays is 0.5%.
dc.abstract.plpl
Celem badanej pracy było znalezienie odpowiedniego stężenia surowiczej albuminy wołowej (BSA) wykorzystywanej do modyfikacji powierzchni bioczujnika elektrochemicznego w oznaczeniach peptydu C. Badano stężenia BSA: 0,25%, 0,5%, 1,0%, 2,0%. BSA blokuje niespecyficzne miejsca wiązania antygenu z przeciwciałem. W przeprowadzonych badaniach jako bioczujnika elektrochemicznego użyto elektrody sitodrukowanej. Składa się ona z elektrody pracującej, pomocniczej i odniesienia. W przeprowadzonych badaniach wykorzystano dwie techniki: woltamperometrię cykliczną (CV) i elektrochemiczną spektroskopię impedancyjną (EIS). Przy użyciu woltamperometrii cyklicznej zarejestrowano woltamperogramy, a na ich podstawie wykreślono zależności kalibracyjne. Z wykonanych wykresów odczytano czułość oraz współczynnik determinacji (liniowość) dla wszystkich badanych stężeń BSA. Za pomocą techniki EIS wyznaczono wartości rezystancji przeniesienia ładunku, pojemości różniczkowej podwójnej warstwy elektrycznej oraz powierzchni aktywnej elektrochemicznie dla badanych stężeń BSA. Przy użyciu tych dwóch technik i ich opracowaniu wykazano, że najbardziej optymalne stężenie BSA w oznaczeniach peptydu C jest równe 0,5%.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Knihnicki, Paweł - 126218
dc.contributor.authorpl
Stańczyk, Diana - USOS302876
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Wieczorek, Marcin - 160176
dc.contributor.reviewerpl
Knihnicki, Paweł - 126218
dc.date.accessioned
2024-07-04T22:58:53Z
dc.date.available
2024-07-04T22:58:53Z
dc.date.submittedpl
2024-07-03
dc.fieldofstudypl
chemia medyczna
dc.identifier.apdpl
diploma-173113-302876
dc.identifier.uri
https://ruj.uj.edu.pl/handle/item/369501
dc.languagepl
pol
dc.subject.enpl
bovine serum albumin (BSA), C-peptide, electrochemical biosensor, screen-printed electrode (SPE), antibody, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS)
dc.subject.plpl
surowicza albumina wołowa (BSA), peptyd C, bioczujnik elektrochemiczny, elektroda sitodrukowana (SPE), przeciwciało, woltamperometria cykliczna (CV), elektrochemiczna spektroskopia impedancyjna (EIS)
dc.titlepl
Albumina wołowa jako składnik kompozytu elektrodowego bioczujnika elektrochemicznego do oznaczania peptydu C
dc.title.alternativepl
Bovine albumin as a component of the electrode composite for an electrochemical biosensor for C-peptide determination
dc.typepl
licenciate
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

No access