Studies of changes of signals shapes in plastic scintillator strips

master
dc.abstract.enThe main aim of this master thesis was to study properties of signals in plasticscintillator detectors with different shapes. The scintillators with the lengthof 500 mm and cross sections of square (14 mm side), hexagonal (9 mm side),triangular (17 mm side) and circular (16 mm and 10mm dia.) were studied.A series of measurements were done with 68 Ge radioactive source placed in leadcollimator. 500 mm long scintillator connected to two photomultipliers by opticalgel and reference detector were used to make an experimental setup.Measurements were performed at 5 positions across each strip. It was observedthat the rise time increases and the fall time decreases with the distance betweenthe irradiation place and photomultiplier.pl
dc.abstract.plGłównym celem pracy magisterskiej były studia własności sygnałóww plastikowych detektorach scyntylacyjnych o różnych kształtach. Przetestowanezostały scyntylatory o długości 500 mm i przekrojach: kwadratowym (14 mm bok),sześciokątnym (9 mm bok), trójkątnym (17 mm bok) i okrągłym (16 mm i 10 mmśrednicy). Wykonano szereg pomiarów przy użyciu radioaktywnego źródła 68 Geumieszczonego w ołowianym kolimatorze. Układ pomiarowy składał się z 500 mmpaska połączonego z dwoma fotopowielaczami przy użyciu żelu optycznego orazdetektora referencyjnego. Pomiary zostały wykonane dla 5 pozycji wzdłuż każdegoz pasków. Zaobserwowano, że czas narastania rośnie, natomiast czas opadaniamaleje, wraz z odległością pomiędzy miejscem naświetlania a fotopowielaczem.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanejpl
dc.contributor.advisorMoskal, Paweł - 100401 pl
dc.contributor.authorPawlik-Niedźwiecka, Monikapl
dc.contributor.departmentbycodeUJK/WFAISpl
dc.contributor.reviewerMoskal, Paweł - 100401 pl
dc.contributor.reviewerSmyrski, Jerzy - 100030 pl
dc.date.accessioned2020-07-25T05:58:41Z
dc.date.available2020-07-25T05:58:41Z
dc.date.submitted2014-11-14pl
dc.fieldofstudyfizyka jądrowapl
dc.identifier.apddiploma-92302-133128pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/200452
dc.languageengpl
dc.subject.enPET tomography, scintillators, signal shapes, J-PET.pl
dc.subject.plTomografia PET, scyntylatory, kształty sygnałów, J-PET.pl
dc.titleStudies of changes of signals shapes in plastic scintillator stripspl
dc.title.alternativeBadanie kształtu impulsów świetlnych w paskowych scyntylatorach polimerowych.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The main aim of this master thesis was to study properties of signals in plasticscintillator detectors with different shapes. The scintillators with the lengthof 500 mm and cross sections of square (14 mm side), hexagonal (9 mm side),triangular (17 mm side) and circular (16 mm and 10mm dia.) were studied.A series of measurements were done with 68 Ge radioactive source placed in leadcollimator. 500 mm long scintillator connected to two photomultipliers by opticalgel and reference detector were used to make an experimental setup.Measurements were performed at 5 positions across each strip. It was observedthat the rise time increases and the fall time decreases with the distance betweenthe irradiation place and photomultiplier.
dc.abstract.plpl
Głównym celem pracy magisterskiej były studia własności sygnałóww plastikowych detektorach scyntylacyjnych o różnych kształtach. Przetestowanezostały scyntylatory o długości 500 mm i przekrojach: kwadratowym (14 mm bok),sześciokątnym (9 mm bok), trójkątnym (17 mm bok) i okrągłym (16 mm i 10 mmśrednicy). Wykonano szereg pomiarów przy użyciu radioaktywnego źródła 68 Geumieszczonego w ołowianym kolimatorze. Układ pomiarowy składał się z 500 mmpaska połączonego z dwoma fotopowielaczami przy użyciu żelu optycznego orazdetektora referencyjnego. Pomiary zostały wykonane dla 5 pozycji wzdłuż każdegoz pasków. Zaobserwowano, że czas narastania rośnie, natomiast czas opadaniamaleje, wraz z odległością pomiędzy miejscem naświetlania a fotopowielaczem.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej
dc.contributor.advisorpl
Moskal, Paweł - 100401
dc.contributor.authorpl
Pawlik-Niedźwiecka, Monika
dc.contributor.departmentbycodepl
UJK/WFAIS
dc.contributor.reviewerpl
Moskal, Paweł - 100401
dc.contributor.reviewerpl
Smyrski, Jerzy - 100030
dc.date.accessioned
2020-07-25T05:58:41Z
dc.date.available
2020-07-25T05:58:41Z
dc.date.submittedpl
2014-11-14
dc.fieldofstudypl
fizyka jądrowa
dc.identifier.apdpl
diploma-92302-133128
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/200452
dc.languagepl
eng
dc.subject.enpl
PET tomography, scintillators, signal shapes, J-PET.
dc.subject.plpl
Tomografia PET, scyntylatory, kształty sygnałów, J-PET.
dc.titlepl
Studies of changes of signals shapes in plastic scintillator strips
dc.title.alternativepl
Badanie kształtu impulsów świetlnych w paskowych scyntylatorach polimerowych.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
10
Views per month
Views per city
Des Moines
2
Krakow
2
Wroclaw
2
Dublin
1
Tarnów
1

No access

No Thumbnail Available