Successful retrieval of a hydrophilic guidewire coating

2007
journal article
article
dc.abstract.enBackground: We present two cases of endovascular retrieval of a hydrophilic guidewire coating, which was stripped off against the needle during coronary angiography. Case report: The first coating was 43 centimeters long and it was located at the course of external iliac artery, common femoral artery and its bifurcation and along the deep femoral artery. In the second case, the foreign body was a couple of centimeters long and located in the proximal part of the deep femoral artery. The coating was captured and successfully retrieved in both cases using 0.009" intermingling guidewires, advanced from the contralateral side in so-called cross-over way. Conclusions: Percutaneous retrieval techniques of endovascular foreign bodies are very effective and safe. Physicians performing endovascular procedures should be familiar with these retrieval techniques.pl
dc.contributor.authorJuszkat, Robertpl
dc.contributor.authorŻabicki, Bartoszpl
dc.contributor.authorGrygier, Marekpl
dc.contributor.authorPawlak, Bogdanpl
dc.date.accession2019-06-26pl
dc.date.accessioned2019-06-26T16:56:22Z
dc.date.available2019-06-26T16:56:22Z
dc.date.issued2007pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 98pl
dc.description.number4pl
dc.description.physical95-98pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume72pl
dc.identifier.articleid510554pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/78085
dc.identifier.weblinkhttp://archiwum.inforadiologia.pl/download/index/idArt/510554pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.encomplicationpl
dc.subject.encoronary angiographypl
dc.subject.enpercutaneous retrievalpl
dc.subject.enhydrophilic guidewirepl
dc.subject.endetached coatingpl
dc.subtypeArticlepl
dc.titleSuccessful retrieval of a hydrophilic guidewire coatingpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: We present two cases of endovascular retrieval of a hydrophilic guidewire coating, which was stripped off against the needle during coronary angiography. Case report: The first coating was 43 centimeters long and it was located at the course of external iliac artery, common femoral artery and its bifurcation and along the deep femoral artery. In the second case, the foreign body was a couple of centimeters long and located in the proximal part of the deep femoral artery. The coating was captured and successfully retrieved in both cases using 0.009" intermingling guidewires, advanced from the contralateral side in so-called cross-over way. Conclusions: Percutaneous retrieval techniques of endovascular foreign bodies are very effective and safe. Physicians performing endovascular procedures should be familiar with these retrieval techniques.
dc.contributor.authorpl
Juszkat, Robert
dc.contributor.authorpl
Żabicki, Bartosz
dc.contributor.authorpl
Grygier, Marek
dc.contributor.authorpl
Pawlak, Bogdan
dc.date.accessionpl
2019-06-26
dc.date.accessioned
2019-06-26T16:56:22Z
dc.date.available
2019-06-26T16:56:22Z
dc.date.issuedpl
2007
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 98
dc.description.numberpl
4
dc.description.physicalpl
95-98
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
72
dc.identifier.articleidpl
510554
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/78085
dc.identifier.weblinkpl
http://archiwum.inforadiologia.pl/download/index/idArt/510554
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
complication
dc.subject.enpl
coronary angiography
dc.subject.enpl
percutaneous retrieval
dc.subject.enpl
hydrophilic guidewire
dc.subject.enpl
detached coating
dc.subtypepl
Article
dc.titlepl
Successful retrieval of a hydrophilic guidewire coating
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
1
Views per month
Views per city
Helsinki
1
Downloads
juszkat_zabicki_grygier_pawlak_successful_retrieval_of_a_hydrophilic_guidewire_coating_2007.pdf
5
juszkat_zabicki_grygier_pawlak_successful_retrieval_of_a_hydrophilic_guidewire_coating_2007.odt
2