dc.abstract.enThe studies presented in this thesis were aimed at the investigation of wire-coated electrodes as possible detectors in liquid chromatography. Composite material built of conductive carbon and polyvinyl chloride (PVC) was applied as the sensoric material (composite electrode). In addition to the blank composite electrode, sensors with additional membranes built of PVC or gelatin A were also investigated. The tests were performed in dynamic conditions as the stream of analyte solution was injected directly on the electrode with the application of flow injection analysis. This method was applied to mimic the conditions typical for the chromatographic detector chamber. In the studies the pH for the working electrodes was optimized with the application of maleic acid as the analyte. To investigate the selectivity and sensitivity of the tested electrodes two additional analytes: malic and tartaric acids were also tested. It turned out that the blank composite electrode does not achieve the parameters required for the effective chromatographic detector. On the other hand, the performed experiments proved that the composite electrode with PVC membrane fulfills all the requirements and can be applied as a detector in liquid chromatography. Special attention was focused on the sensors with the gelatin A membrane. The results of the preliminary tests are promising. However, further studies regarding the analytical processes optimization and the further elaboration of the electrode construction are necessary.pl
dc.abstract.plCelem niniejszej pracy było przebadanie elektrod powlekanych (typu „coated wire”) pod kątem ich zastosowania jako potencjometrycznych detektorów w chromatografii cieczowej. Jako element sensoryczny zastosowano materiał kompozytowy wykonany z połączenia przewodzącego węgla i polichlorku winylu (PCV) (elektroda kompozytowa). Przebadano niepokrytą elektrodę kompozytową jak i dodatkowo modyfikowaną poprzez naniesienie membrany z PCV lub też membrany utworzonej z żelatyny typu A. Badania przeprowadzono w dynamicznych warunkach podając strumień analitu na testowane elektrody za pomocą wstrzykowej analizy przepływowej. Metodę tę zastosowano celowo, by symulować warunki panujące w komorze detektora chromatograficznego. W badaniach zoptymalizowano pH pracy elektrod stosując kwas maleinowy jako analiz testowy. W celu przeprowadzenia badań selektywności oraz czułości testowanych elektrod zastosowano dwa dodatkowe anality: kwas jabłkowy i kwas winowy. Okazało się, że elektroda kompozytowa bez dodatkowej membrany nie osiąga parametrów oczekiwanych dla detektora chromatograficznego. Natomiast przeprowadzone badania dowiodły, ze elektroda kompozytowa z membraną z PCV spełnia wymagania stawiane detektorom potencjometrycznym stosowanym w chromatografii. Wiele uwagi poświęcono sensorom z membraną wykonaną z żelatyny typu A. Wyniki wstępnych testów są obiecujące, jednakże konieczne jest przeprowadzenie dalszych badań dotyczących optymalizacji procesu analizy z wykorzystaniem tego typu sensora, jak również dopracowanie konstrukcji tej elektrody.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.areaobszar nauk przyrodniczychpl
dc.contributor.advisorBroniatowski, Marcin - 127429 pl
dc.contributor.authorMleczkowska, Agatapl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerSulka, Grzegorz - 132161 pl
dc.contributor.reviewerBroniatowski, Marcin - 127429 pl
dc.date.accessioned2020-07-24T13:01:50Z
dc.date.available2020-07-24T13:01:50Z
dc.date.submitted2012-10-18pl
dc.fieldofstudyochrona środowiskapl
dc.identifier.apddiploma-71630-86484pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/184696
dc.languageengpl
dc.subject.encoated wire electrode, Gel Apl
dc.subject.plElektroda powlekana, coated wire, Żel Apl
dc.titleTestowanie powłok typu żelowego w celu ich zastosowania w powlekanych czujnikach potencjometrycznych.pl
dc.titleTesting gelatin-type coating materials for use in coated wire potentiometric sensors.pl
dc.title.alternativeTestowanie powłok typu żelowego w celu ich zastosowania w powlekanych czujnikach potencjometrycznych.pl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The studies presented in this thesis were aimed at the investigation of wire-coated electrodes as possible detectors in liquid chromatography. Composite material built of conductive carbon and polyvinyl chloride (PVC) was applied as the sensoric material (composite electrode). In addition to the blank composite electrode, sensors with additional membranes built of PVC or gelatin A were also investigated. The tests were performed in dynamic conditions as the stream of analyte solution was injected directly on the electrode with the application of flow injection analysis. This method was applied to mimic the conditions typical for the chromatographic detector chamber. In the studies the pH for the working electrodes was optimized with the application of maleic acid as the analyte. To investigate the selectivity and sensitivity of the tested electrodes two additional analytes: malic and tartaric acids were also tested. It turned out that the blank composite electrode does not achieve the parameters required for the effective chromatographic detector. On the other hand, the performed experiments proved that the composite electrode with PVC membrane fulfills all the requirements and can be applied as a detector in liquid chromatography. Special attention was focused on the sensors with the gelatin A membrane. The results of the preliminary tests are promising. However, further studies regarding the analytical processes optimization and the further elaboration of the electrode construction are necessary.
dc.abstract.plpl
Celem niniejszej pracy było przebadanie elektrod powlekanych (typu „coated wire”) pod kątem ich zastosowania jako potencjometrycznych detektorów w chromatografii cieczowej. Jako element sensoryczny zastosowano materiał kompozytowy wykonany z połączenia przewodzącego węgla i polichlorku winylu (PCV) (elektroda kompozytowa). Przebadano niepokrytą elektrodę kompozytową jak i dodatkowo modyfikowaną poprzez naniesienie membrany z PCV lub też membrany utworzonej z żelatyny typu A. Badania przeprowadzono w dynamicznych warunkach podając strumień analitu na testowane elektrody za pomocą wstrzykowej analizy przepływowej. Metodę tę zastosowano celowo, by symulować warunki panujące w komorze detektora chromatograficznego. W badaniach zoptymalizowano pH pracy elektrod stosując kwas maleinowy jako analiz testowy. W celu przeprowadzenia badań selektywności oraz czułości testowanych elektrod zastosowano dwa dodatkowe anality: kwas jabłkowy i kwas winowy. Okazało się, że elektroda kompozytowa bez dodatkowej membrany nie osiąga parametrów oczekiwanych dla detektora chromatograficznego. Natomiast przeprowadzone badania dowiodły, ze elektroda kompozytowa z membraną z PCV spełnia wymagania stawiane detektorom potencjometrycznym stosowanym w chromatografii. Wiele uwagi poświęcono sensorom z membraną wykonaną z żelatyny typu A. Wyniki wstępnych testów są obiecujące, jednakże konieczne jest przeprowadzenie dalszych badań dotyczących optymalizacji procesu analizy z wykorzystaniem tego typu sensora, jak również dopracowanie konstrukcji tej elektrody.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.areapl
obszar nauk przyrodniczych
dc.contributor.advisorpl
Broniatowski, Marcin - 127429
dc.contributor.authorpl
Mleczkowska, Agata
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Sulka, Grzegorz - 132161
dc.contributor.reviewerpl
Broniatowski, Marcin - 127429
dc.date.accessioned
2020-07-24T13:01:50Z
dc.date.available
2020-07-24T13:01:50Z
dc.date.submittedpl
2012-10-18
dc.fieldofstudypl
ochrona środowiska
dc.identifier.apdpl
diploma-71630-86484
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/184696
dc.languagepl
eng
dc.subject.enpl
coated wire electrode, Gel A
dc.subject.plpl
Elektroda powlekana, coated wire, Żel A
dc.titlepl
Testowanie powłok typu żelowego w celu ich zastosowania w powlekanych czujnikach potencjometrycznych.
dc.titlepl
Testing gelatin-type coating materials for use in coated wire potentiometric sensors.
dc.title.alternativepl
Testowanie powłok typu żelowego w celu ich zastosowania w powlekanych czujnikach potencjometrycznych.
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

No access

No Thumbnail Available