Badania nad możliwością zastosowania systemu cyfrowego obrazowania w opracowaniu mikroprzepływowego urządzenia analityczno-diagnostycznego do określenia zakresu stężenia litu

master
dc.abstract.enThe thesis concerns research on checking the possibility of using a digital imaging system as a detection element in a microfluidic analytical and diagnostic device based on paper as a base material (µPAD) to determine the range of lithium concentration.In the literature section, bipolar affective disorder and the therapeutic importance of lithium in its treatment, as well as the analytical methods used to determine lithium are described. Analytical sensors, including microfluidic paper analytical devices, are characterized, paying attention to their preparation methods and possible applications for analytical purposes. In addition, information on digital imaging systems and some of their applications in chemical analysis are presented.In the experimental part, the course of research related to the selection of a reagent that could be applied in a microfluidic analytical-diagnostic device for lithium determination using a digital imaging system as a detection element is presented. An attempt was also made to use a digital imaging system to determine the range of lithium concentration in which it could be determined after transferring the selected reagent to a properly prepared paper that could form the basis for the development of µPAD.pl
dc.abstract.plPraca dotyczy badań nad sprawdzeniem możliwości zastosowania systemu cyfrowego obrazowania jako elementu detekcyjnego w opracowywanym mikroprzepływowym urządzeniu analityczno-diagnostycznym na bazie papieru jako materiału bazowego (µPAD) do określenia zakresu stężenia litu. W części teoretycznej pracy opisano chorobę afektywną dwubiegunową i znaczenie terapeutyczne litu w jej leczeniu, przybliżono metody analityczne wykorzystywane do oznaczania litu. Scharakteryzowano także czujniki analityczne, w tym mikroprzepływowe papierowe urządzenia analityczne zwracając uwagę na sposoby ich przygotowania i możliwości zastosowania do celów analitycznych. Ponadto przedstawiono informacje dotyczące systemów cyfrowego obrazowania oraz wybranych ich zastosowań w analizie chemicznej.W części doświadczalnej przedstawiono przebieg badań związanych z doborem odczynnika, który mógłby znaleźć zastosowanie w mikroprzepływowym urządzeniu analityczno-diagnostycznym do oznaczania litu z wykorzystaniem systemu cyfrowego obrazowania jako elementu detekcyjnego. Podjęto także próbę wykorzystania systemu cyfrowego obrazowania do wyznaczenia zakresu stężenia litu, w którym możliwe byłoby jego oznaczanie po przeniesieniu wybranego odczynnika na odpowiednio przygotowaną bibułę mogąca stanowić podstawę do opracowania µPAD.pl
dc.affiliationWydział Chemiipl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorKozak, Joanna - 129327 pl
dc.contributor.authorSzulczewska, Małgorzatapl
dc.contributor.departmentbycodeUJK/WC3pl
dc.contributor.reviewerKozak, Joanna - 129327 pl
dc.contributor.reviewerWieczorek, Marcin - 160176 pl
dc.date.accessioned2020-10-20T18:48:00Z
dc.date.available2020-10-20T18:48:00Z
dc.date.submitted2020-10-01pl
dc.fieldofstudychemia medycznapl
dc.identifier.apddiploma-138313-215088pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/248793
dc.languagepolpl
dc.source.integratorfalse
dc.subject.enLithium, thorin, spectrophotometric analysis, μPADpl
dc.subject.plLit, toron, analiza spektrofotometryczna, μPADpl
dc.titleBadania nad możliwością zastosowania systemu cyfrowego obrazowania w opracowaniu mikroprzepływowego urządzenia analityczno-diagnostycznego do określenia zakresu stężenia litupl
dc.title.alternativeResearch on the possibility of using a digital imaging system in the development of microfluidic analytical and diagnostic device to determine the range of lithium concentrationpl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The thesis concerns research on checking the possibility of using a digital imaging system as a detection element in a microfluidic analytical and diagnostic device based on paper as a base material (µPAD) to determine the range of lithium concentration.In the literature section, bipolar affective disorder and the therapeutic importance of lithium in its treatment, as well as the analytical methods used to determine lithium are described. Analytical sensors, including microfluidic paper analytical devices, are characterized, paying attention to their preparation methods and possible applications for analytical purposes. In addition, information on digital imaging systems and some of their applications in chemical analysis are presented.In the experimental part, the course of research related to the selection of a reagent that could be applied in a microfluidic analytical-diagnostic device for lithium determination using a digital imaging system as a detection element is presented. An attempt was also made to use a digital imaging system to determine the range of lithium concentration in which it could be determined after transferring the selected reagent to a properly prepared paper that could form the basis for the development of µPAD.
dc.abstract.plpl
Praca dotyczy badań nad sprawdzeniem możliwości zastosowania systemu cyfrowego obrazowania jako elementu detekcyjnego w opracowywanym mikroprzepływowym urządzeniu analityczno-diagnostycznym na bazie papieru jako materiału bazowego (µPAD) do określenia zakresu stężenia litu. W części teoretycznej pracy opisano chorobę afektywną dwubiegunową i znaczenie terapeutyczne litu w jej leczeniu, przybliżono metody analityczne wykorzystywane do oznaczania litu. Scharakteryzowano także czujniki analityczne, w tym mikroprzepływowe papierowe urządzenia analityczne zwracając uwagę na sposoby ich przygotowania i możliwości zastosowania do celów analitycznych. Ponadto przedstawiono informacje dotyczące systemów cyfrowego obrazowania oraz wybranych ich zastosowań w analizie chemicznej.W części doświadczalnej przedstawiono przebieg badań związanych z doborem odczynnika, który mógłby znaleźć zastosowanie w mikroprzepływowym urządzeniu analityczno-diagnostycznym do oznaczania litu z wykorzystaniem systemu cyfrowego obrazowania jako elementu detekcyjnego. Podjęto także próbę wykorzystania systemu cyfrowego obrazowania do wyznaczenia zakresu stężenia litu, w którym możliwe byłoby jego oznaczanie po przeniesieniu wybranego odczynnika na odpowiednio przygotowaną bibułę mogąca stanowić podstawę do opracowania µPAD.
dc.affiliationpl
Wydział Chemii
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Kozak, Joanna - 129327
dc.contributor.authorpl
Szulczewska, Małgorzata
dc.contributor.departmentbycodepl
UJK/WC3
dc.contributor.reviewerpl
Kozak, Joanna - 129327
dc.contributor.reviewerpl
Wieczorek, Marcin - 160176
dc.date.accessioned
2020-10-20T18:48:00Z
dc.date.available
2020-10-20T18:48:00Z
dc.date.submittedpl
2020-10-01
dc.fieldofstudypl
chemia medyczna
dc.identifier.apdpl
diploma-138313-215088
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/248793
dc.languagepl
pol
dc.source.integrator
false
dc.subject.enpl
Lithium, thorin, spectrophotometric analysis, μPAD
dc.subject.plpl
Lit, toron, analiza spektrofotometryczna, μPAD
dc.titlepl
Badania nad możliwością zastosowania systemu cyfrowego obrazowania w opracowaniu mikroprzepływowego urządzenia analityczno-diagnostycznego do określenia zakresu stężenia litu
dc.title.alternativepl
Research on the possibility of using a digital imaging system in the development of microfluidic analytical and diagnostic device to determine the range of lithium concentration
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
14
Views per month
Views per city
Krakow
5
Wroclaw
3
Chicago
1
Dublin
1
Hangzhou
1
Plaza
1
Porąbka Uszewska
1
Radom
1

No access

No Thumbnail Available