Artefakty w badaniu rezonansu magnetycznego.

licenciate
dc.abstract.enMagnetic Resonance Imaging (MRI) is a diagnostic method using phenomena occuring for hydrogen nuclei placed in a strong, static magnetic field and subjected to alternating magnetic fields. A factor that significantly reduces the diagnostic value of MR scanning is the presence of artifacts. Artifacts are undesirable elements present in an MR image that do not have a real, physical reflection in the imaged organism. They may hinder or prevent radiological interpretation of the test and may give rise to misdiagnosis.The first part of the thesis is a presentation of the structure and operation of an MR scanner and also the way the MR image is obtained. The second part of the study concerns selected artifacts, description of their formation and ways of their elimination or reduction of adverse effects on the diagnostic value of the study. The division into three categories of artefacts was applied, according to the cause of their creation: patient-related, software-related and hardware-related.pl
dc.abstract.plRezonans Magnetyczny jest metodą diagnostyczną wykorzystującą zjawiska zachodzące dla jąder wodoru umieszczonych w silnym, statycznym polu magnetycznym i poddawanym działaniu zmiennych pól magnetycznych. Czynnikiem znacznie wpływającym na obniżenie wartości diagnostycznej badania MR jest obecność artefaktów. Artefakty to elementy niepożądane, obecne na obrazie MR, które nie posiadają rzeczywistego, fizycznego odzwierciedlenia w obrazowanym organizmie. Mogą utrudniać lub uniemożliwiać interpretację radiologiczną badania i być przyczyną powstania błędów diagnostycznych. Część pierwsza pracy to przedstawienie budowy i zasady działania aparatu MR oraz sposobu powstawania obrazu MR.Część druga pracy dotyczy wybranych artefaktów, opisu sposobu ich powstawania oraz sposobów ich eliminacji bądź ograniczenia niekorzystnego wpływu na wartość diagnostyczną badania. Zastosowany został podział na trzy kategorie artefaktów, ze względu na przyczynę powstawania, związane z pacjentem, ze sposobem otrzymywania obrazu oraz ze sprzętem.pl
dc.affiliationWydział Nauk o Zdrowiupl
dc.areaobszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznejpl
dc.contributor.advisorKarcz, Paulinapl
dc.contributor.authorPłatek, Gabrielapl
dc.contributor.departmentbycodeUJK/WNOZpl
dc.contributor.reviewerKarcz, Paulinapl
dc.contributor.reviewerDubis, Anna - 173912 pl
dc.date.accessioned2020-08-24T10:58:44Z
dc.date.available2020-08-24T10:58:44Z
dc.date.submitted2020-08-12pl
dc.fieldofstudyelektroradiologiapl
dc.identifier.apddiploma-143842-248705pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/244562
dc.languagepolpl
dc.subject.enMagnetic Resonance Imaging (MRI), artifact, image qualitypl
dc.subject.plRezonans Magnetyczny (MRI), artefakt, jakość obrazupl
dc.titleArtefakty w badaniu rezonansu magnetycznego.pl
dc.title.alternativeArtifacts in Magnetic Resonance Imagingpl
dc.typelicenciatepl
dspace.entity.typePublication
dc.abstract.enpl
Magnetic Resonance Imaging (MRI) is a diagnostic method using phenomena occuring for hydrogen nuclei placed in a strong, static magnetic field and subjected to alternating magnetic fields. A factor that significantly reduces the diagnostic value of MR scanning is the presence of artifacts. Artifacts are undesirable elements present in an MR image that do not have a real, physical reflection in the imaged organism. They may hinder or prevent radiological interpretation of the test and may give rise to misdiagnosis.The first part of the thesis is a presentation of the structure and operation of an MR scanner and also the way the MR image is obtained. The second part of the study concerns selected artifacts, description of their formation and ways of their elimination or reduction of adverse effects on the diagnostic value of the study. The division into three categories of artefacts was applied, according to the cause of their creation: patient-related, software-related and hardware-related.
dc.abstract.plpl
Rezonans Magnetyczny jest metodą diagnostyczną wykorzystującą zjawiska zachodzące dla jąder wodoru umieszczonych w silnym, statycznym polu magnetycznym i poddawanym działaniu zmiennych pól magnetycznych. Czynnikiem znacznie wpływającym na obniżenie wartości diagnostycznej badania MR jest obecność artefaktów. Artefakty to elementy niepożądane, obecne na obrazie MR, które nie posiadają rzeczywistego, fizycznego odzwierciedlenia w obrazowanym organizmie. Mogą utrudniać lub uniemożliwiać interpretację radiologiczną badania i być przyczyną powstania błędów diagnostycznych. Część pierwsza pracy to przedstawienie budowy i zasady działania aparatu MR oraz sposobu powstawania obrazu MR.Część druga pracy dotyczy wybranych artefaktów, opisu sposobu ich powstawania oraz sposobów ich eliminacji bądź ograniczenia niekorzystnego wpływu na wartość diagnostyczną badania. Zastosowany został podział na trzy kategorie artefaktów, ze względu na przyczynę powstawania, związane z pacjentem, ze sposobem otrzymywania obrazu oraz ze sprzętem.
dc.affiliationpl
Wydział Nauk o Zdrowiu
dc.areapl
obszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznej
dc.contributor.advisorpl
Karcz, Paulina
dc.contributor.authorpl
Płatek, Gabriela
dc.contributor.departmentbycodepl
UJK/WNOZ
dc.contributor.reviewerpl
Karcz, Paulina
dc.contributor.reviewerpl
Dubis, Anna - 173912
dc.date.accessioned
2020-08-24T10:58:44Z
dc.date.available
2020-08-24T10:58:44Z
dc.date.submittedpl
2020-08-12
dc.fieldofstudypl
elektroradiologia
dc.identifier.apdpl
diploma-143842-248705
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/244562
dc.languagepl
pol
dc.subject.enpl
Magnetic Resonance Imaging (MRI), artifact, image quality
dc.subject.plpl
Rezonans Magnetyczny (MRI), artefakt, jakość obrazu
dc.titlepl
Artefakty w badaniu rezonansu magnetycznego.
dc.title.alternativepl
Artifacts in Magnetic Resonance Imaging
dc.typepl
licenciate
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

No access

No Thumbnail Available