Wpływ pola magnetycznego i prądów Tens na ciśnienie tętnicze

master
dc.abstract.enThe aim of this work was the analysis of the current and burst TENS low-frequency magnetic field impact on the parameters of blood pressure in individuals with hypertension and without hypertension. The study was conducted to show if there are any correlations between burst TENS currents and magnetic field and hypertension changes in both groups.The research group consisted of 80 people aged 40-67 years (mean age 52,55±7,27).They were classified into 2 groups:1.Control group – without hypertension2.Experimental group- with hypertensionThe research was conducted based on the data obtained from the author's questionnaire survey, measurements of blood pressure record. All patients had blood pressure taken before and after the magnetic field and electric current TENS treatments.The results analysis showed that the magnetic field treatment induced blood pressure reduction. While TENS current treatment did not affect the change of blood pressure value.These results provide the following conclusions:•The occurrence of differences in blood pressure values after the magnetic field and TENS currents treatments.•There is a correlation between patient's age and change in blood pressure.•The lack of correlation between sex and blood pressure.•The occurrence of various ailments between TENS currents and magnetic field.pl
dc.abstract.plCelem mojej pracy była analiza wpływu prądu TENS burst oraz pola magnetycznego o niskiej częstotliwości na parametry ciśnienia tętniczego krwi u osób z nadciśnieniem tętniczym oraz bez nadciśnienia tętniczego. Przeprowadzone badania miały wykazać czy istnieją korelacje pomiędzy prądami TENS burst oraz polem magnetycznym a zmianami ciśnienia tętniczego w obu badanych grupach.Grupę badawczą stanowiło 80 osób w wieku 40-67 lat (średnia wieku 52,55±7,27)Badani zostali podzieleni na 2 grupy:1.Grupa kontrolna - osoby bez nadciśnienia tętniczego (n=40).2.Grupa badawcza - osoby z nadciśnieniem tętniczym (n=40).Badania przeprowadzono na podstawie danych uzyskanych z autorskiego kwestionariusza - ankiety oraz karty pomiaru ciśnienia tętniczego. U wszystkich pacjentów wykonywano pomiar ciśnienia tętniczego przed i po zabiegach polem magnetycznym oraz prądem TENS.Przeprowadzona analiza wyników badań wykazała, iż zabieg polem magnetycznym wywoływał u pacjentów obniżenie ciśnienia tętniczego. Natomiast zabieg prądem TENS nie wpływał na zmianę wartości ciśnienia tętniczego.Uzyskane wyniki pozwalają na sformułowanie następujących wniosków:•Występują różnice w wartościach ciśnienia tętniczego po zabiegu polem magnetycznym a prądem TENS.•Istnieje zależność pomiędzy wiekiem pacjenta a zmianą ciśnienia tętniczego.•Brak korelacji pomiędzy płcią a ciśnieniem tętniczym.•Występują zróżnicowane dolegliwości pomiędzy zabiegiem TENS a polem magnetycznym.pl
dc.affiliationWydział Nauk o Zdrowiupl
dc.areaobszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznejpl
dc.contributor.advisorMazur-Biały, Agnieszka - 141891 pl
dc.contributor.authorWilk, Małgorzatapl
dc.contributor.departmentbycodeUJK/WNOZpl
dc.contributor.reviewerMazur-Biały, Agnieszka - 141891 pl
dc.contributor.reviewerBilski, Jan - 128783 pl
dc.date.accessioned2020-07-26T20:18:22Z
dc.date.available2020-07-26T20:18:22Z
dc.date.submitted2016-10-14pl
dc.fieldofstudyfizjoterapiapl
dc.identifier.apddiploma-103577-198836pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/210086
dc.languagepolpl
dc.subject.enBlood pressure, magnetic field,TENS currentspl
dc.subject.plCiśnienie tętnicze,pole magnetyczne, prądy TENSpl
dc.titleWpływ pola magnetycznego i prądów Tens na ciśnienie tętniczepl
dc.title.alternativeThe magnetic field and Tens currents impact on blood pressurepl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
The aim of this work was the analysis of the current and burst TENS low-frequency magnetic field impact on the parameters of blood pressure in individuals with hypertension and without hypertension. The study was conducted to show if there are any correlations between burst TENS currents and magnetic field and hypertension changes in both groups.The research group consisted of 80 people aged 40-67 years (mean age 52,55±7,27).They were classified into 2 groups:1.Control group – without hypertension2.Experimental group- with hypertensionThe research was conducted based on the data obtained from the author's questionnaire survey, measurements of blood pressure record. All patients had blood pressure taken before and after the magnetic field and electric current TENS treatments.The results analysis showed that the magnetic field treatment induced blood pressure reduction. While TENS current treatment did not affect the change of blood pressure value.These results provide the following conclusions:•The occurrence of differences in blood pressure values after the magnetic field and TENS currents treatments.•There is a correlation between patient's age and change in blood pressure.•The lack of correlation between sex and blood pressure.•The occurrence of various ailments between TENS currents and magnetic field.
dc.abstract.plpl
Celem mojej pracy była analiza wpływu prądu TENS burst oraz pola magnetycznego o niskiej częstotliwości na parametry ciśnienia tętniczego krwi u osób z nadciśnieniem tętniczym oraz bez nadciśnienia tętniczego. Przeprowadzone badania miały wykazać czy istnieją korelacje pomiędzy prądami TENS burst oraz polem magnetycznym a zmianami ciśnienia tętniczego w obu badanych grupach.Grupę badawczą stanowiło 80 osób w wieku 40-67 lat (średnia wieku 52,55±7,27)Badani zostali podzieleni na 2 grupy:1.Grupa kontrolna - osoby bez nadciśnienia tętniczego (n=40).2.Grupa badawcza - osoby z nadciśnieniem tętniczym (n=40).Badania przeprowadzono na podstawie danych uzyskanych z autorskiego kwestionariusza - ankiety oraz karty pomiaru ciśnienia tętniczego. U wszystkich pacjentów wykonywano pomiar ciśnienia tętniczego przed i po zabiegach polem magnetycznym oraz prądem TENS.Przeprowadzona analiza wyników badań wykazała, iż zabieg polem magnetycznym wywoływał u pacjentów obniżenie ciśnienia tętniczego. Natomiast zabieg prądem TENS nie wpływał na zmianę wartości ciśnienia tętniczego.Uzyskane wyniki pozwalają na sformułowanie następujących wniosków:•Występują różnice w wartościach ciśnienia tętniczego po zabiegu polem magnetycznym a prądem TENS.•Istnieje zależność pomiędzy wiekiem pacjenta a zmianą ciśnienia tętniczego.•Brak korelacji pomiędzy płcią a ciśnieniem tętniczym.•Występują zróżnicowane dolegliwości pomiędzy zabiegiem TENS a polem magnetycznym.
dc.affiliationpl
Wydział Nauk o Zdrowiu
dc.areapl
obszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznej
dc.contributor.advisorpl
Mazur-Biały, Agnieszka - 141891
dc.contributor.authorpl
Wilk, Małgorzata
dc.contributor.departmentbycodepl
UJK/WNOZ
dc.contributor.reviewerpl
Mazur-Biały, Agnieszka - 141891
dc.contributor.reviewerpl
Bilski, Jan - 128783
dc.date.accessioned
2020-07-26T20:18:22Z
dc.date.available
2020-07-26T20:18:22Z
dc.date.submittedpl
2016-10-14
dc.fieldofstudypl
fizjoterapia
dc.identifier.apdpl
diploma-103577-198836
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/210086
dc.languagepl
pol
dc.subject.enpl
Blood pressure, magnetic field,TENS currents
dc.subject.plpl
Ciśnienie tętnicze,pole magnetyczne, prądy TENS
dc.titlepl
Wpływ pola magnetycznego i prądów Tens na ciśnienie tętnicze
dc.title.alternativepl
The magnetic field and Tens currents impact on blood pressure
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
3101
Views per month
Views per city
Warsaw
539
Krakow
182
Poznan
149
Wroclaw
137
Katowice
113
Gdansk
89
Lodz
88
Lublin
63
Rzeszów
51
Bydgoszcz
28

No access

No Thumbnail Available