The utility of virtual monochromatic dual-energy computed tomography (DECT) in meniscal imaging : a technical evaluation
dual-energy CT
meniscus
contrast resolution
Bibliogr. s. e327
Purpose: To determine the feasibility of meniscal imaging using virtual monochromatic images obtained through dualenergy computed tomography (DECT) technique, and to determine which keV levels optimise contrast resolution. Material and methods: All DECT exams were performed on a Discovery CT750 HD system from GE Healthcare. Virtual monochromatic images were reconstructed at 40 keV, 73 keV, 106 keV, and 139 keV. Contrast resolution of the medial and lateral menisci using a 5-point Likert scale at each keV level was determined through a consensus agreement by 2 fellowship-trained musculoskeletal radiologists. Friedman's and Wilcoxon signed rank tests were used to compare visualisation scores across different keV levels. Results: Seventeen knee exams from 10 patients met criteria for inclusion in the study. All patients included in the study cohort were male. The median age of patients was 46 years (interquartile range, 35-53 years). Virtual monochromatic images at 40 keV demonstrated highest contrast resolution of the menisci, with a statistically significant difference between contrast resolution scores at 40 keV and 76 keV, Friedman test: p < 0.0001.Conclusions: Meniscal imaging is feasible using DECT virtual monochromatic images at low keV levels. Improved contrast resolution at these specified KeV values could pave the way for further research in this field to determine its role in the future as an alternative option for assessment of the menisci in patients with contraindications to MRI or in the setting of a periarticular ferromagnetic foreign body obscuring the field of view.
dc.abstract.en | Purpose: To determine the feasibility of meniscal imaging using virtual monochromatic images obtained through dualenergy computed tomography (DECT) technique, and to determine which keV levels optimise contrast resolution. Material and methods: All DECT exams were performed on a Discovery CT750 HD system from GE Healthcare. Virtual monochromatic images were reconstructed at 40 keV, 73 keV, 106 keV, and 139 keV. Contrast resolution of the medial and lateral menisci using a 5-point Likert scale at each keV level was determined through a consensus agreement by 2 fellowship-trained musculoskeletal radiologists. Friedman's and Wilcoxon signed rank tests were used to compare visualisation scores across different keV levels. Results: Seventeen knee exams from 10 patients met criteria for inclusion in the study. All patients included in the study cohort were male. The median age of patients was 46 years (interquartile range, 35-53 years). Virtual monochromatic images at 40 keV demonstrated highest contrast resolution of the menisci, with a statistically significant difference between contrast resolution scores at 40 keV and 76 keV, Friedman test: p < 0.0001.Conclusions: Meniscal imaging is feasible using DECT virtual monochromatic images at low keV levels. Improved contrast resolution at these specified KeV values could pave the way for further research in this field to determine its role in the future as an alternative option for assessment of the menisci in patients with contraindications to MRI or in the setting of a periarticular ferromagnetic foreign body obscuring the field of view. | |
dc.contributor.author | Adams, Scott | |
dc.contributor.author | van Heerden, Jacques | |
dc.contributor.author | Reis, Jodie | |
dc.contributor.author | Mondal, Prosanta | |
dc.contributor.author | Shepel, Michael | |
dc.contributor.author | Obaid, Haron | |
dc.date.accessioned | 2025-08-01T06:34:27Z | |
dc.date.available | 2025-08-01T06:34:27Z | |
dc.date.createdat | 2025-08-01T06:34:27Z | en |
dc.date.issued | 2024 | |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. e327 | |
dc.description.physical | e324-e327 | |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 89 | |
dc.identifier.doi | 10.5114/pjr/187934 | |
dc.identifier.issn | 1733-134X | |
dc.identifier.project | DRC AI | |
dc.identifier.uri | https://ruj.uj.edu.pl/handle/item/558626 | |
dc.language | eng | |
dc.language.container | eng | |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | |
dc.share.type | otwarte czasopismo | |
dc.subject.en | dual-energy CT | |
dc.subject.en | meniscus | |
dc.subject.en | contrast resolution | |
dc.subtype | Article | |
dc.title | The utility of virtual monochromatic dual-energy computed tomography (DECT) in meniscal imaging : a technical evaluation | |
dc.title.journal | Polish Journal of Radiology | |
dc.type | JournalArticle | |
dspace.entity.type | Publication | en |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
8
Views per month
Views per city
Downloads
Open Access