Evaluation of single-chip, real-time tomographic data processing on FPGA SoC devices

2018
journal article
article
88
dc.abstract.enA novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian positron emission tomography scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead, we introduce a field programmable gate array system-on-chip platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search, and region-of-response reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiegopl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Zakład Technologii Gierpl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Zakład Technologii Informatycznychpl
dc.contributor.authorKorcyl, Grzegorz - 107362 pl
dc.contributor.authorBiałas, Piotr - 127296 pl
dc.contributor.authorCurceanu, C.pl
dc.contributor.authorCzerwiński, Eryk - 102850 pl
dc.contributor.authorDulski, Kamil - 204579 pl
dc.contributor.authorFlak, B.pl
dc.contributor.authorGajos, Aleksander - 164087 pl
dc.contributor.authorGłowacz, Bartosz - 135174 pl
dc.contributor.authorGorgol, M.pl
dc.contributor.authorHiesmayr, B. C.pl
dc.contributor.authorJasińska, B.pl
dc.contributor.authorKacprzak, Krzysztofpl
dc.contributor.authorKajetanowicz, M.pl
dc.contributor.authorKisielewska, Daria - 179828 pl
dc.contributor.authorKowalski, P.pl
dc.contributor.authorKozik, Tomasz - 129362 pl
dc.contributor.authorKrawczyk, Nikodem - 176270 pl
dc.contributor.authorKrzemień, Wojciech - 135126 pl
dc.contributor.authorKubicz, Ewelina - 177092 pl
dc.contributor.authorMohammed, Muhsin - 236400 pl
dc.contributor.authorNiedźwiecki, Szymon - 115136 pl
dc.contributor.authorPawlik-Niedźwiecka, Monika - 193996 pl
dc.contributor.authorPałka, Marek - 214237 pl
dc.contributor.authorRaczyński, L.pl
dc.contributor.authorRajda, P.pl
dc.contributor.authorRudy, Zbigniew - 100004 pl
dc.contributor.authorSalabura, Piotr - 102313 pl
dc.contributor.authorGupta-Sharma, Neha - 235987 pl
dc.contributor.authorSharma, Sushil - 200161 pl
dc.contributor.authorShopa, R. Y.pl
dc.contributor.authorSkurzok, Magdalena - 106557 pl
dc.contributor.authorSilarski, Michał - 103624 pl
dc.contributor.authorStrzempek, Paweł - 115552 pl
dc.contributor.authorWieczorek, Anna - 163447 pl
dc.contributor.authorWiślicki, W.pl
dc.contributor.authorZaleski, R.pl
dc.contributor.authorZgardzińska, B.pl
dc.contributor.authorZieliński, Marcin - 124902 pl
dc.contributor.authorMoskal, Paweł - 100401 pl
dc.date.accessioned2018-11-08T13:47:46Z
dc.date.available2018-11-08T13:47:46Z
dc.date.issued2018pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.number11pl
dc.description.physical2526-2535pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume37pl
dc.identifier.doi10.1109/TMI.2018.2837741pl
dc.identifier.eissn1558-254Xpl
dc.identifier.issn0278-0062pl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/59773
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa*
dc.rights.licenceCC-BY
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/legalcode.pl*
dc.share.typeinne
dc.subtypeArticlepl
dc.titleEvaluation of single-chip, real-time tomographic data processing on FPGA SoC devicespl
dc.title.journalIEEE Transactions on Medical Imagingpl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian positron emission tomography scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead, we introduce a field programmable gate array system-on-chip platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search, and region-of-response reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Zakład Technologii Gier
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Zakład Technologii Informatycznych
dc.contributor.authorpl
Korcyl, Grzegorz - 107362
dc.contributor.authorpl
Białas, Piotr - 127296
dc.contributor.authorpl
Curceanu, C.
dc.contributor.authorpl
Czerwiński, Eryk - 102850
dc.contributor.authorpl
Dulski, Kamil - 204579
dc.contributor.authorpl
Flak, B.
dc.contributor.authorpl
Gajos, Aleksander - 164087
dc.contributor.authorpl
Głowacz, Bartosz - 135174
dc.contributor.authorpl
Gorgol, M.
dc.contributor.authorpl
Hiesmayr, B. C.
dc.contributor.authorpl
Jasińska, B.
dc.contributor.authorpl
Kacprzak, Krzysztof
dc.contributor.authorpl
Kajetanowicz, M.
dc.contributor.authorpl
Kisielewska, Daria - 179828
dc.contributor.authorpl
Kowalski, P.
dc.contributor.authorpl
Kozik, Tomasz - 129362
dc.contributor.authorpl
Krawczyk, Nikodem - 176270
dc.contributor.authorpl
Krzemień, Wojciech - 135126
dc.contributor.authorpl
Kubicz, Ewelina - 177092
dc.contributor.authorpl
Mohammed, Muhsin - 236400
dc.contributor.authorpl
Niedźwiecki, Szymon - 115136
dc.contributor.authorpl
Pawlik-Niedźwiecka, Monika - 193996
dc.contributor.authorpl
Pałka, Marek - 214237
dc.contributor.authorpl
Raczyński, L.
dc.contributor.authorpl
Rajda, P.
dc.contributor.authorpl
Rudy, Zbigniew - 100004
dc.contributor.authorpl
Salabura, Piotr - 102313
dc.contributor.authorpl
Gupta-Sharma, Neha - 235987
dc.contributor.authorpl
Sharma, Sushil - 200161
dc.contributor.authorpl
Shopa, R. Y.
dc.contributor.authorpl
Skurzok, Magdalena - 106557
dc.contributor.authorpl
Silarski, Michał - 103624
dc.contributor.authorpl
Strzempek, Paweł - 115552
dc.contributor.authorpl
Wieczorek, Anna - 163447
dc.contributor.authorpl
Wiślicki, W.
dc.contributor.authorpl
Zaleski, R.
dc.contributor.authorpl
Zgardzińska, B.
dc.contributor.authorpl
Zieliński, Marcin - 124902
dc.contributor.authorpl
Moskal, Paweł - 100401
dc.date.accessioned
2018-11-08T13:47:46Z
dc.date.available
2018-11-08T13:47:46Z
dc.date.issuedpl
2018
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.numberpl
11
dc.description.physicalpl
2526-2535
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
37
dc.identifier.doipl
10.1109/TMI.2018.2837741
dc.identifier.eissnpl
1558-254X
dc.identifier.issnpl
0278-0062
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/59773
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa
dc.rights.licence
CC-BY
dc.rights.uri*
http://creativecommons.org/licenses/by/4.0/legalcode.pl
dc.share.type
inne
dc.subtypepl
Article
dc.titlepl
Evaluation of single-chip, real-time tomographic data processing on FPGA SoC devices
dc.title.journalpl
IEEE Transactions on Medical Imaging
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
11
Views per month
Views per city
Ashburn
10
Downloads
korcyl_et-al_evaluation_of_single-chip_real-time_tomographic_data_processing_2018.pdf
34
korcyl_et-al_evaluation_of_single-chip_real-time_tomographic_data_processing_2018.odt
3