Diagnostic performance of cone-beam computed tomography for apical periodontitis : a systematic review and meta-analysis

2023
journal article
review article
3
dc.abstract.enPurpose: We aimed to conduct a systematic review and meta-analysis of studies examining the performance of conebeam computed tomography (CBCT) imaging in apical periodontitis (AP) prediction. This was done to address the contradictory results reported in the existing literature on this topic. Material and methods: We searched the Embase, PubMed, Cochrane library, and Scopus databases for literature published from inception to 30 June 2023 without language restriction using appropriate keywords. We included studies that reported the diagnostic accuracy values of CBCT in AP detection among humans by comparing AP diagnosis with a control group without lesions. We pooled the diagnostic accuracy values using a random effects model and presented the estimates as percentage and 95% confidence interval (CI). The heterogeneity between the surveys was explored by I2 statistic. Results: Out of 301 citations initially identified, a total of 8 eligible studies were finally included. According to the analyses, the overall pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) estimated for CBCT were 94.6% (95% CI: 90.2-97.1; I2 = 55.9%, p = 0.026), 91.2% (95% CI: 81.7-96.0; I2 = 81.6%, p < 0.001), 93.0% (95% CI: 87.4-96.2; I2 = 56.5%, p = 0.024), and 92.3% (95% CI: 82.3-96.8; I2 = 86.4%, p < 0.001), respectively. The overall pooled sensitivity, specificity, PPV, and NPV of digital radiography were 61.0% (95% CI: 38.3-79.8; I 2 = 94.4%, p < 0.001), 97.3% (95% CI: 85.6-99.5; I 2 = 86.7%, p < 0.001), 98.3% (95% CI: 92.0-99.6; I2 = 74.4%, p = 0.002), and 41.6% (95% CI: 28.0-56.6; I2 = 89.5%, p < 0.001), respectively. Conclusions: CBCT imaging has excellent diagnostic accuracy in AP prediction. Also, CBCT has better discriminant test performance for AP than digital radiography.
dc.contributor.authorAbesi, Farida
dc.contributor.authorGolikani, Ali
dc.date.accessioned2024-07-26T08:44:39Z
dc.date.available2024-07-26T08:44:39Z
dc.date.issued2023
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e604-e605
dc.description.physicale597-e605
dc.description.versionostateczna wersja wydawcy
dc.description.volume88
dc.identifier.doi10.5114/pjr.2023.134035
dc.identifier.issn1733-134X
dc.identifier.urihttps://ruj.uj.edu.pl/handle/item/389521
dc.languageeng
dc.language.containereng
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.typeotwarte czasopismo
dc.subject.encone-beam computed tomography
dc.subject.enradiography
dc.subject.enapical periodontitis
dc.subject.enaccuracy
dc.subject.ensensitivity
dc.subject.enspecificity
dc.subtypeReviewArticle
dc.titleDiagnostic performance of cone-beam computed tomography for apical periodontitis : a systematic review and meta-analysis
dc.title.journalPolish Journal of Radiology
dc.typeJournalArticle
dspace.entity.typePublicationen
dc.abstract.en
Purpose: We aimed to conduct a systematic review and meta-analysis of studies examining the performance of conebeam computed tomography (CBCT) imaging in apical periodontitis (AP) prediction. This was done to address the contradictory results reported in the existing literature on this topic. Material and methods: We searched the Embase, PubMed, Cochrane library, and Scopus databases for literature published from inception to 30 June 2023 without language restriction using appropriate keywords. We included studies that reported the diagnostic accuracy values of CBCT in AP detection among humans by comparing AP diagnosis with a control group without lesions. We pooled the diagnostic accuracy values using a random effects model and presented the estimates as percentage and 95% confidence interval (CI). The heterogeneity between the surveys was explored by I2 statistic. Results: Out of 301 citations initially identified, a total of 8 eligible studies were finally included. According to the analyses, the overall pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) estimated for CBCT were 94.6% (95% CI: 90.2-97.1; I2 = 55.9%, p = 0.026), 91.2% (95% CI: 81.7-96.0; I2 = 81.6%, p < 0.001), 93.0% (95% CI: 87.4-96.2; I2 = 56.5%, p = 0.024), and 92.3% (95% CI: 82.3-96.8; I2 = 86.4%, p < 0.001), respectively. The overall pooled sensitivity, specificity, PPV, and NPV of digital radiography were 61.0% (95% CI: 38.3-79.8; I 2 = 94.4%, p < 0.001), 97.3% (95% CI: 85.6-99.5; I 2 = 86.7%, p < 0.001), 98.3% (95% CI: 92.0-99.6; I2 = 74.4%, p = 0.002), and 41.6% (95% CI: 28.0-56.6; I2 = 89.5%, p < 0.001), respectively. Conclusions: CBCT imaging has excellent diagnostic accuracy in AP prediction. Also, CBCT has better discriminant test performance for AP than digital radiography.
dc.contributor.author
Abesi, Farida
dc.contributor.author
Golikani, Ali
dc.date.accessioned
2024-07-26T08:44:39Z
dc.date.available
2024-07-26T08:44:39Z
dc.date.issued
2023
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additional
Bibliogr. s. e604-e605
dc.description.physical
e597-e605
dc.description.version
ostateczna wersja wydawcy
dc.description.volume
88
dc.identifier.doi
10.5114/pjr.2023.134035
dc.identifier.issn
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/handle/item/389521
dc.language
eng
dc.language.container
eng
dc.rights
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.en
cone-beam computed tomography
dc.subject.en
radiography
dc.subject.en
apical periodontitis
dc.subject.en
accuracy
dc.subject.en
sensitivity
dc.subject.en
specificity
dc.subtype
ReviewArticle
dc.title
Diagnostic performance of cone-beam computed tomography for apical periodontitis : a systematic review and meta-analysis
dc.title.journal
Polish Journal of Radiology
dc.type
JournalArticle
dspace.entity.typeen
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
5
Views per month
Views per city
Krakow
4
Downloads
abesi_golikani_diagnostic_performance_of_cone-beam_computed_tomography_2023.pdf
11