Diagnostic accuracy of microvascular flow imaging ultrasound for endoleak detection after endovascular aortic aneurysm repair : a systematic review and meta-analysis

2024
journal article
review article
dc.abstract.enThe objective was to assess the diagnostic accuracy of microvascular flow imaging ultrasound (MVUS) for the detection of endoleak after endovascular aortic aneurysm repair. A systematic search of the literature published until January 2024 was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses of Diagnostic Test Accuracy (PRISMA-DTA) guidelines. The pooled rates of sensitivity, specificity, and diagnostic odds ratio of MVUS in endoleak detection with computed tomography angiography as the reference standard were estimated using univariate random-effect analysis with 95% confidence intervals. Three studies were considered eligible for inclusion. Superb micro vascular imaging (SMI) was used as an MVUS technique in all cases. The total number of paired scans was 209. Sensitivity and specificity of the individual studies ranged 0.75-1.00 and 0.93-1.00, respectively. Pooled sensitivity and specificity of the SMI method was 0.91 (CI: 0.82-0.96) and 0.98 (CI: 0.94-1.00), respectively. The pooled diagnostic odds ratio was 635 (95% CI: 128-3140). The findings of the present study support the use of the MVUS for endoleak detection. However, further research is warranted to explore the broader application of MVUS, providing a more comprehensive understanding and establishing robust criteria for its role in clinical practice.
dc.contributor.authorCzeczelewski, Marcin
dc.contributor.authorKopyto, Ewa
dc.contributor.authorKuczyńska, Maryla
dc.contributor.authorDrelich-Zbroja, Anna
dc.contributor.authorJargiełło, Tomasz
dc.date.accessioned2025-08-18T08:01:49Z
dc.date.available2025-08-18T08:01:49Z
dc.date.createdat2025-08-18T08:01:49Zen
dc.date.issued2024
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e419
dc.description.physicale414-e419
dc.description.versionostateczna wersja wydawcy
dc.description.volume89
dc.identifier.doi10.5114/pjr/190502
dc.identifier.issn1733-134X
dc.identifier.projectDRC AI
dc.identifier.urihttps://ruj.uj.edu.pl/handle/item/559013
dc.languageeng
dc.language.containereng
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.typeotwarte czasopismo
dc.subject.enendovascular aneurysm repair
dc.subject.enultrasonography
dc.subject.enmicrocirculation
dc.subject.enmeta-analysis
dc.subtypeReviewArticle
dc.titleDiagnostic accuracy of microvascular flow imaging ultrasound for endoleak detection after endovascular aortic aneurysm repair : a systematic review and meta-analysis
dc.title.journalPolish Journal of Radiology
dc.typeJournalArticle
dspace.entity.typePublicationen
dc.abstract.en
The objective was to assess the diagnostic accuracy of microvascular flow imaging ultrasound (MVUS) for the detection of endoleak after endovascular aortic aneurysm repair. A systematic search of the literature published until January 2024 was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses of Diagnostic Test Accuracy (PRISMA-DTA) guidelines. The pooled rates of sensitivity, specificity, and diagnostic odds ratio of MVUS in endoleak detection with computed tomography angiography as the reference standard were estimated using univariate random-effect analysis with 95% confidence intervals. Three studies were considered eligible for inclusion. Superb micro vascular imaging (SMI) was used as an MVUS technique in all cases. The total number of paired scans was 209. Sensitivity and specificity of the individual studies ranged 0.75-1.00 and 0.93-1.00, respectively. Pooled sensitivity and specificity of the SMI method was 0.91 (CI: 0.82-0.96) and 0.98 (CI: 0.94-1.00), respectively. The pooled diagnostic odds ratio was 635 (95% CI: 128-3140). The findings of the present study support the use of the MVUS for endoleak detection. However, further research is warranted to explore the broader application of MVUS, providing a more comprehensive understanding and establishing robust criteria for its role in clinical practice.
dc.contributor.author
Czeczelewski, Marcin
dc.contributor.author
Kopyto, Ewa
dc.contributor.author
Kuczyńska, Maryla
dc.contributor.author
Drelich-Zbroja, Anna
dc.contributor.author
Jargiełło, Tomasz
dc.date.accessioned
2025-08-18T08:01:49Z
dc.date.available
2025-08-18T08:01:49Z
dc.date.createdaten
2025-08-18T08:01:49Z
dc.date.issued
2024
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additional
Bibliogr. s. e419
dc.description.physical
e414-e419
dc.description.version
ostateczna wersja wydawcy
dc.description.volume
89
dc.identifier.doi
10.5114/pjr/190502
dc.identifier.issn
1733-134X
dc.identifier.project
DRC AI
dc.identifier.uri
https://ruj.uj.edu.pl/handle/item/559013
dc.language
eng
dc.language.container
eng
dc.rights
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.en
endovascular aneurysm repair
dc.subject.en
ultrasonography
dc.subject.en
microcirculation
dc.subject.en
meta-analysis
dc.subtype
ReviewArticle
dc.title
Diagnostic accuracy of microvascular flow imaging ultrasound for endoleak detection after endovascular aortic aneurysm repair : a systematic review and meta-analysis
dc.title.journal
Polish Journal of Radiology
dc.type
JournalArticle
dspace.entity.typeen
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
12
Views per month
Views per city
Krakow
9
Downloads
czeczelewski_et-al_diagnostic_accuracy_of_microvascular_flow_imaging_ultrasound_2024.pdf
16