Simple view
Full metadata view
Authors
Statistics
Rotating polarization magnetometry
optical atomic magnetometry
optically pumped magnetometers
nonlinear magneto-optical rotation
light with continuously rotating linear polarization
amplitudemodulated light
alignment-to-orientation conversion
Precise magnetometry is vital in numerous scientific and technological applications. At the forefront of sensitivity, optical atomic magnetometry, particularly techniques utilizing nonlinear magneto-optical rotation (NMOR), enables ultraprecise measurements across a broad field range. Despite their potential, these techniques reportedly lose sensitivity in higher magnetic fields, which is attributed to the alignment-to-orientation conversion (AOC) process. In our study, we utilized light with continuously rotating linear polarization to avoid the AOC, which produced robust optical signals and achieving high magnetometric sensitivity over a dynamic range nearly three times greater than Earth’s magnetic field. We demonstrated that employing rotating polarization surpasses other NMOR techniques that use modulated light. Our findings also indicate that the previously observed signal deterioration was not due to the AOC, suggesting an alternative cause for this decline.
| dc.abstract.en | Precise magnetometry is vital in numerous scientific and technological applications. At the forefront of sensitivity, optical atomic magnetometry, particularly techniques utilizing nonlinear magneto-optical rotation (NMOR), enables ultraprecise measurements across a broad field range. Despite their potential, these techniques reportedly lose sensitivity in higher magnetic fields, which is attributed to the alignment-to-orientation conversion (AOC) process. In our study, we utilized light with continuously rotating linear polarization to avoid the AOC, which produced robust optical signals and achieving high magnetometric sensitivity over a dynamic range nearly three times greater than Earth’s magnetic field. We demonstrated that employing rotating polarization surpasses other NMOR techniques that use modulated light. Our findings also indicate that the previously observed signal deterioration was not due to the AOC, suggesting an alternative cause for this decline. | |
| dc.affiliation | Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego | |
| dc.contributor.author | Pustelny, Szymon - 102458 | |
| dc.contributor.author | Włodarczyk, Przemysław - 242783 | |
| dc.date.accessioned | 2025-11-06T09:30:11Z | |
| dc.date.available | 2025-11-06T09:30:11Z | |
| dc.date.createdat | 2025-11-03T10:42:36Z | en |
| dc.date.issued | 2025 | |
| dc.date.openaccess | 0 | |
| dc.description.accesstime | w momencie opublikowania | |
| dc.description.number | 9 | |
| dc.description.version | ostateczna wersja wydawcy | |
| dc.description.volume | 25 | |
| dc.identifier.articleid | 2682 | |
| dc.identifier.doi | 10.3390/s25092682 | |
| dc.identifier.eissn | 1424-3210 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.project | DRC AI | |
| dc.identifier.uri | https://ruj.uj.edu.pl/handle/item/564942 | |
| dc.language | eng | |
| dc.language.container | eng | |
| dc.rights | Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa | |
| dc.rights.licence | CC-BY | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/legalcode.pl | |
| dc.share.type | otwarte czasopismo | |
| dc.source.integrator | false | |
| dc.subject.en | optical atomic magnetometry | |
| dc.subject.en | optically pumped magnetometers | |
| dc.subject.en | nonlinear magneto-optical rotation | |
| dc.subject.en | light with continuously rotating linear polarization | |
| dc.subject.en | amplitudemodulated light | |
| dc.subject.en | alignment-to-orientation conversion | |
| dc.subtype | Article | |
| dc.title | Rotating polarization magnetometry | |
| dc.title.journal | Sensors | |
| dc.type | JournalArticle | |
| dspace.entity.type | Publication | en |