Mikroskopowa weryfikacja komunikatów ostrzegawczych o nieprawidłowościach układu białokrwinkowego w wynikach morfologii krwi uzyskanych z analizatorów hematologicznych

master
dc.abstract.enPeripheral blood smear is a referential method in the diagnostics of haematology diseases. A long duration of manually executed microscopic analysis causes that producers of haematology analysers improve devices to correct a decision process. This thesis covers a topic regarding a microscopic verification of white blood cells system warning statements issued via haematology analyser Sysmex XN-1000 (Sysmex Corporation, Kobe, Japan). For research purposes there were selected blood samples collected into K2EDTA, the results of which were provided with warning statements, especially: “IG Present”, “Left Shift?”, “Blasts?”, “Abn Lympho?”, “WBC Abn Scattergram”. The smears were made by wedge method and stained by Wright's dye. The evaluation was accomplished by a light microscope under 1000x magnification. The correctness of warning statements, the relation between NEUT-GI parameter and parameters related to neutrophil morphology was verified by analysing results from the analyser and peripheral blood smear. Another aim of research was an analysis of factors which could have an influence on the occurrence of so called “low reliability of the result”.It was confirmed that haematology analyser Sysmex XN-1000 well detects the presence of irregular leukocytes, which denotes them by proper statements. An influence of neutrophil morphology was noticed during the appearance of “Left Shift?” flag. Also, there was observed a dependency between NEUT-GI parameter from the analyser and the percentage of neutrophils with toxic granularity. It was proven that the low reliability of the result is related to neutrophil hyposegmentation.pl
dc.abstract.plRozmaz krwi obwodowej jest metodą referencyjną w diagnostyce chorób hematologicznych. Czasochłonność wykonywanej manualnie analizy mikroskopowej sprawia, że producenci analizatorów hematologicznych udoskonalają urządzenia, aby usprawnić proces decyzyjny. Niniejsza praca obejmuje tematykę dotyczącą mikroskopowej weryfikacji komunikatów ostrzegawczych dotyczących układu białokrwinkowego wydawanych przez analizator hematologiczny Sysmex XN-1000 (Sysmex Corporation, Kobe, Japonia). Do badania wybrano próbki krwi pobranej na K2EDTA, których wyniki opatrzone były komunikatami ostrzegawczymi, w szczególności: „IG Present”, „Left Shift?”, „Blasts?”, „Abn Lympho”, “WBC Abn Scattergram”. Wykonano rozmazy metodą klina i wybarwiono barwnikiem Wrighta. Oceny dokonywano za pomocą mikroskopu świetlnego, pod powiększeniem 1000-krotnym. Analizując wyniki z analizatora oraz z rozmazu krwi obwodowej weryfikowano poprawność komunikatów ostrzegawczych, zależność pomiędzy parametrem NEUT-GI z parametrami związanymi z morfologią neutrofili. Kolejnym celem badania była analiza czynników, które mogłyby wypływać na pojawienie się tzw. „niskiej wiarygodności wyniku”Stwierdzono, że analizator hematologiczny XN-1000 z dobrym rezultatem wykrywa obecność nieprawidłowych leukocytów, oznaczając ich obecność odpowiednimi komunikatami. Zauważono wpływ morfologii neutrofili na pojawienie się flagi „Left Shift?”. Spostrzeżono również zależność pomiędzy parametrem NEUT-GI z analizatora oraz odsetkiem neutrofili z ziarnistościami toksycznymi. Wykazano, że wystąpienie niskiej wiarygodności wyniku jest związane z odsetkiem neutrofili z hiposegmentowanym jądrem komórkowym.pl
dc.affiliationWydział Farmaceutycznypl
dc.areaobszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznejpl
dc.contributor.advisorTisończyk, Joanna - 173978 pl
dc.contributor.authorTabas, Małgorzatapl
dc.contributor.departmentbycodeUJK/WFOAM2pl
dc.contributor.reviewerTisończyk, Joanna - 173978 pl
dc.contributor.reviewerKrzyściak, Wirginia - 133053 pl
dc.date.accessioned2023-06-28T21:30:59Z
dc.date.available2023-06-28T21:30:59Z
dc.date.submitted2023-06-28pl
dc.fieldofstudyanalityka medycznapl
dc.identifier.apddiploma-163454-258373pl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/313055
dc.languagepolpl
dc.subject.enPheripheral blood, smear, leukocytes, hematology analyzer, Sysmex XN-1000, verification of warning statementspl
dc.subject.plKrew obwodowa, rozmaz, leukocyty, analizator hematologiczny, Sysmex XN-1000, weryfikacja komunikatów ostrzegawczychpl
dc.titleMikroskopowa weryfikacja komunikatów ostrzegawczych o nieprawidłowościach układu białokrwinkowego w wynikach morfologii krwi uzyskanych z analizatorów hematologicznychpl
dc.title.alternativeMicroscopic verification of warning statements about abnormalities of the white blood cell system in the results of blood counts obtained from hematology analyzerspl
dc.typemasterpl
dspace.entity.typePublication
dc.abstract.enpl
Peripheral blood smear is a referential method in the diagnostics of haematology diseases. A long duration of manually executed microscopic analysis causes that producers of haematology analysers improve devices to correct a decision process. This thesis covers a topic regarding a microscopic verification of white blood cells system warning statements issued via haematology analyser Sysmex XN-1000 (Sysmex Corporation, Kobe, Japan). For research purposes there were selected blood samples collected into K2EDTA, the results of which were provided with warning statements, especially: “IG Present”, “Left Shift?”, “Blasts?”, “Abn Lympho?”, “WBC Abn Scattergram”. The smears were made by wedge method and stained by Wright's dye. The evaluation was accomplished by a light microscope under 1000x magnification. The correctness of warning statements, the relation between NEUT-GI parameter and parameters related to neutrophil morphology was verified by analysing results from the analyser and peripheral blood smear. Another aim of research was an analysis of factors which could have an influence on the occurrence of so called “low reliability of the result”.It was confirmed that haematology analyser Sysmex XN-1000 well detects the presence of irregular leukocytes, which denotes them by proper statements. An influence of neutrophil morphology was noticed during the appearance of “Left Shift?” flag. Also, there was observed a dependency between NEUT-GI parameter from the analyser and the percentage of neutrophils with toxic granularity. It was proven that the low reliability of the result is related to neutrophil hyposegmentation.
dc.abstract.plpl
Rozmaz krwi obwodowej jest metodą referencyjną w diagnostyce chorób hematologicznych. Czasochłonność wykonywanej manualnie analizy mikroskopowej sprawia, że producenci analizatorów hematologicznych udoskonalają urządzenia, aby usprawnić proces decyzyjny. Niniejsza praca obejmuje tematykę dotyczącą mikroskopowej weryfikacji komunikatów ostrzegawczych dotyczących układu białokrwinkowego wydawanych przez analizator hematologiczny Sysmex XN-1000 (Sysmex Corporation, Kobe, Japonia). Do badania wybrano próbki krwi pobranej na K2EDTA, których wyniki opatrzone były komunikatami ostrzegawczymi, w szczególności: „IG Present”, „Left Shift?”, „Blasts?”, „Abn Lympho”, “WBC Abn Scattergram”. Wykonano rozmazy metodą klina i wybarwiono barwnikiem Wrighta. Oceny dokonywano za pomocą mikroskopu świetlnego, pod powiększeniem 1000-krotnym. Analizując wyniki z analizatora oraz z rozmazu krwi obwodowej weryfikowano poprawność komunikatów ostrzegawczych, zależność pomiędzy parametrem NEUT-GI z parametrami związanymi z morfologią neutrofili. Kolejnym celem badania była analiza czynników, które mogłyby wypływać na pojawienie się tzw. „niskiej wiarygodności wyniku”Stwierdzono, że analizator hematologiczny XN-1000 z dobrym rezultatem wykrywa obecność nieprawidłowych leukocytów, oznaczając ich obecność odpowiednimi komunikatami. Zauważono wpływ morfologii neutrofili na pojawienie się flagi „Left Shift?”. Spostrzeżono również zależność pomiędzy parametrem NEUT-GI z analizatora oraz odsetkiem neutrofili z ziarnistościami toksycznymi. Wykazano, że wystąpienie niskiej wiarygodności wyniku jest związane z odsetkiem neutrofili z hiposegmentowanym jądrem komórkowym.
dc.affiliationpl
Wydział Farmaceutyczny
dc.areapl
obszar nauk medycznych, nauk o zdrowiu oraz nauk o kulturze fizycznej
dc.contributor.advisorpl
Tisończyk, Joanna - 173978
dc.contributor.authorpl
Tabas, Małgorzata
dc.contributor.departmentbycodepl
UJK/WFOAM2
dc.contributor.reviewerpl
Tisończyk, Joanna - 173978
dc.contributor.reviewerpl
Krzyściak, Wirginia - 133053
dc.date.accessioned
2023-06-28T21:30:59Z
dc.date.available
2023-06-28T21:30:59Z
dc.date.submittedpl
2023-06-28
dc.fieldofstudypl
analityka medyczna
dc.identifier.apdpl
diploma-163454-258373
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/313055
dc.languagepl
pol
dc.subject.enpl
Pheripheral blood, smear, leukocytes, hematology analyzer, Sysmex XN-1000, verification of warning statements
dc.subject.plpl
Krew obwodowa, rozmaz, leukocyty, analizator hematologiczny, Sysmex XN-1000, weryfikacja komunikatów ostrzegawczych
dc.titlepl
Mikroskopowa weryfikacja komunikatów ostrzegawczych o nieprawidłowościach układu białokrwinkowego w wynikach morfologii krwi uzyskanych z analizatorów hematologicznych
dc.title.alternativepl
Microscopic verification of warning statements about abnormalities of the white blood cell system in the results of blood counts obtained from hematology analyzers
dc.typepl
master
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
122
Views per month
Views per city
Warsaw
16
Krakow
13
Katowice
6
Lodz
6
Gorzów Wielkopolski
4
Hong Kong
4
Lublin
3
Piaseczno
3
Wroclaw
3
Bialystok
2

No access

No Thumbnail Available
Collections