Wykorzystanie metody TRPS do pomiaru wielkości komórek nowotworowych

licenciate
dc.abstract.enThe aim of this study was to present Tunable Resistive Pulse Sensing (TRPS) method and applies it to determine the size of cells. Tumor cells of human retinoblastoma (line Y79) have been studied. qMicro system (Izon) with micropore MP50 has been used to carry out an experiment. Before starting, the cancer cells were suspended in glucose solutions with different concentration and the system was calibrated. For each sample, three measurement series were performed to verify the reproducibility of the measurements. The diameter of cells, expressed in micrometers, was the direct results of each measurement. It is shown that the research using TRPS method are reproducible and the concentration of glucose did not affect cell size. The average size of human retinoblastoma cells is equal: d= 20,64±3,70 μm.pl
dc.abstract.plCelem pracy było przedstawienie metody badawczej Tunable Resistive Pulse Sensing (TRPS) oraz zastosowanie jej do wyznaczania wielkości komórek. Badania prowadzono na komórkach nowotworowych siatkówczaka ludzkiego, linii Y79. W pomiarach wykorzystano urządzenie qMicro, firmy Izon, wraz z mikroporem MP50. Przed rozpoczęciem badań komórki zawieszono w roztworach glukozy o różnym stężeniu oraz przeprowadzano kalibrację układu. Wykonano 3 serie pomiarowe dla każdej próbki w celu sprawdzenia powtarzalności pomiarów. Średnica badanych komórek wyrażona w mikrometrach była bezpośrednim wynikiem każdego pomiaru. Pokazano, że badania z zastosowaniem wspomnianej metody są powtarzalne oraz że stężenie roztworu glukozy nie ma wpływu na wielkość komórek. Wyznaczono średnią wielkość komórek siatkówczaka ludzkiego: d= 20,64±3,70 μm.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanejpl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorStępień, Ewa - 161583 pl
dc.contributor.authorPasternak, Bernadettapl
dc.contributor.departmentbycodeUJK/WFAISpl
dc.contributor.reviewerPrzybyło, Małgorzata - 131574 pl
dc.contributor.reviewerStępień, Ewa - 161583 pl
dc.date.accessioned2020-07-26T23:28:38Z
dc.date.available2020-07-26T23:28:38Z
dc.date.submitted2016-09-30pl
dc.fieldofstudyfizyka medycznapl
dc.identifier.apddiploma-106724-183758pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/213040
dc.languagepolpl
dc.subject.encancer cells, Tunable Resistive Pulse Sensing, qMicro, microporepl
dc.subject.plkomórki nowotworowe, Tunable Resistive Pulse Sensing, qMicro, mikroporpl
dc.titleWykorzystanie metody TRPS do pomiaru wielkości komórek nowotworowychpl
dc.title.alternativeUsing TRPS method to determine the size of cancer cellspl
dc.typelicenciatepl
dspace.entity.typePublication
dc.abstract.enpl
The aim of this study was to present Tunable Resistive Pulse Sensing (TRPS) method and applies it to determine the size of cells. Tumor cells of human retinoblastoma (line Y79) have been studied. qMicro system (Izon) with micropore MP50 has been used to carry out an experiment. Before starting, the cancer cells were suspended in glucose solutions with different concentration and the system was calibrated. For each sample, three measurement series were performed to verify the reproducibility of the measurements. The diameter of cells, expressed in micrometers, was the direct results of each measurement. It is shown that the research using TRPS method are reproducible and the concentration of glucose did not affect cell size. The average size of human retinoblastoma cells is equal: d= 20,64±3,70 μm.
dc.abstract.plpl
Celem pracy było przedstawienie metody badawczej Tunable Resistive Pulse Sensing (TRPS) oraz zastosowanie jej do wyznaczania wielkości komórek. Badania prowadzono na komórkach nowotworowych siatkówczaka ludzkiego, linii Y79. W pomiarach wykorzystano urządzenie qMicro, firmy Izon, wraz z mikroporem MP50. Przed rozpoczęciem badań komórki zawieszono w roztworach glukozy o różnym stężeniu oraz przeprowadzano kalibrację układu. Wykonano 3 serie pomiarowe dla każdej próbki w celu sprawdzenia powtarzalności pomiarów. Średnica badanych komórek wyrażona w mikrometrach była bezpośrednim wynikiem każdego pomiaru. Pokazano, że badania z zastosowaniem wspomnianej metody są powtarzalne oraz że stężenie roztworu glukozy nie ma wpływu na wielkość komórek. Wyznaczono średnią wielkość komórek siatkówczaka ludzkiego: d= 20,64±3,70 μm.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Stępień, Ewa - 161583
dc.contributor.authorpl
Pasternak, Bernadetta
dc.contributor.departmentbycodepl
UJK/WFAIS
dc.contributor.reviewerpl
Przybyło, Małgorzata - 131574
dc.contributor.reviewerpl
Stępień, Ewa - 161583
dc.date.accessioned
2020-07-26T23:28:38Z
dc.date.available
2020-07-26T23:28:38Z
dc.date.submittedpl
2016-09-30
dc.fieldofstudypl
fizyka medyczna
dc.identifier.apdpl
diploma-106724-183758
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/213040
dc.languagepl
pol
dc.subject.enpl
cancer cells, Tunable Resistive Pulse Sensing, qMicro, micropore
dc.subject.plpl
komórki nowotworowe, Tunable Resistive Pulse Sensing, qMicro, mikropor
dc.titlepl
Wykorzystanie metody TRPS do pomiaru wielkości komórek nowotworowych
dc.title.alternativepl
Using TRPS method to determine the size of cancer cells
dc.typepl
licenciate
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
46
Views per month
Views per city
Krakow
10
Warsaw
5
Ashburn
4
Katowice
3
Chorowice
2
Poznan
2
Wroclaw
2
Dublin
1
Gliwice
1
Szczecin
1

No access

No Thumbnail Available